199 related articles for article (PubMed ID: 11410110)
1. Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle.
van Beekvelt MC; Borghuis MS; van Engelen BG; Wevers RA; Colier WN
Clin Sci (Lond); 2001 Jul; 101(1):21-8. PubMed ID: 11410110
[TBL] [Abstract][Full Text] [Related]
2. Effect of adipose tissue thickness, muscle site, and sex on near-infrared spectroscopy derived total-[hemoglobin + myoglobin].
Craig JC; Broxterman RM; Wilcox SL; Chen C; Barstow TJ
J Appl Physiol (1985); 2017 Dec; 123(6):1571-1578. PubMed ID: 28935822
[TBL] [Abstract][Full Text] [Related]
3. Performance of near-infrared spectroscopy in measuring local O(2) consumption and blood flow in skeletal muscle.
Van Beekvelt MC; Colier WN; Wevers RA; Van Engelen BG
J Appl Physiol (1985); 2001 Feb; 90(2):511-9. PubMed ID: 11160049
[TBL] [Abstract][Full Text] [Related]
4. Reliability of muscle blood flow and oxygen consumption response from exercise using near-infrared spectroscopy.
Lucero AA; Addae G; Lawrence W; Neway B; Credeur DP; Faulkner J; Rowlands D; Stoner L
Exp Physiol; 2018 Jan; 103(1):90-100. PubMed ID: 29034529
[TBL] [Abstract][Full Text] [Related]
5. Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise.
McManus CJ; Collison J; Cooper CE
J Biomed Opt; 2018 Jan; 23(1):1-14. PubMed ID: 29368457
[TBL] [Abstract][Full Text] [Related]
6. In vivo quantitative near-infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise.
van Beekvelt MC; van Engelen BG; Wevers RA; Colier WN
Clin Physiol Funct Imaging; 2002 May; 22(3):210-7. PubMed ID: 12076348
[TBL] [Abstract][Full Text] [Related]
7. Possible Influences on the Interpretation of Functional Domain (FD) Near-Infrared Spectroscopy (NIRS): An Explorative Study.
Celie BM; Boone J; Dumortier J; Derave W; De Backer T; Bourgois JG
Appl Spectrosc; 2016 Feb; 70(2):363-71. PubMed ID: 26903570
[TBL] [Abstract][Full Text] [Related]
8. Methodological validation of the dynamic heterogeneity of muscle deoxygenation within the quadriceps during cycle exercise.
Koga S; Poole DC; Fukuoka Y; Ferreira LF; Kondo N; Ohmae E; Barstow TJ
Am J Physiol Regul Integr Comp Physiol; 2011 Aug; 301(2):R534-41. PubMed ID: 21632845
[TBL] [Abstract][Full Text] [Related]
9. Delayed reoxygenation after maximal isometric handgrip exercise in high oxidative capacity muscle.
Kime R; Hamaoka T; Sako T; Murakami M; Homma T; Katsumura T; Chance B
Eur J Appl Physiol; 2003 Mar; 89(1):34-41. PubMed ID: 12627303
[TBL] [Abstract][Full Text] [Related]
10. Assessing functional sympatholysis during rhythmic handgrip exercise using Doppler ultrasound and near-infrared spectroscopy: sex differences and test-retest reliability.
Teixeira AL; Garland M; Lee JB; Nardone M; Millar PJ
Am J Physiol Regul Integr Comp Physiol; 2022 Nov; 323(5):R810-R821. PubMed ID: 36189987
[TBL] [Abstract][Full Text] [Related]
11. The use of near infrared spectroscopy in sports medicine.
Quaresima V; Lepanto R; Ferrari M
J Sports Med Phys Fitness; 2003 Mar; 43(1):1-13. PubMed ID: 12629456
[TBL] [Abstract][Full Text] [Related]
12. Muscle metabolism from near infrared spectroscopy during rhythmic handgrip in humans.
Boushel R; Pott F; Madsen P; Rådegran G; Nowak M; Quistorff B; Secher N
Eur J Appl Physiol Occup Physiol; 1998 Dec; 79(1):41-8. PubMed ID: 10052659
[TBL] [Abstract][Full Text] [Related]
13. Mapping of hemodynamics on the human calf with near infrared spectroscopy and the influence of the adipose tissue thickness.
Wolf U; Wolf M; Choi JH; Paunescu LA; Safonova LP; Michalos A; Gratton E
Adv Exp Med Biol; 2003; 510():225-30. PubMed ID: 12580432
[TBL] [Abstract][Full Text] [Related]
14. Measurement of muscle blood flow and O
Dennis JJ; Wiggins CC; Smith JR; Isautier JMJ; Johnson BD; Joyner MJ; Cross TJ
Sci Rep; 2021 Jan; 11(1):918. PubMed ID: 33441688
[TBL] [Abstract][Full Text] [Related]
15. The influence of adipose tissue on spatially resolved near-infrared spectroscopy derived skeletal muscle oxygenation: the extent of the problem.
Niemeijer VM; Jansen JP; van Dijk T; Spee RF; Meijer EJ; Kemps HM; Wijn PF
Physiol Meas; 2017 Mar; 38(3):539-554. PubMed ID: 28151429
[TBL] [Abstract][Full Text] [Related]
16. Near-infrared spectroscopy provides an index of blood flow and vasoconstriction in calf skeletal muscle during lower body negative pressure.
Hachiya T; Blaber AP; Saito M
Acta Physiol (Oxf); 2008 Jun; 193(2):117-27. PubMed ID: 18162057
[TBL] [Abstract][Full Text] [Related]
17. Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy.
De Blasi RA; Ferrari M; Natali A; Conti G; Mega A; Gasparetto A
J Appl Physiol (1985); 1994 Mar; 76(3):1388-93. PubMed ID: 8005887
[TBL] [Abstract][Full Text] [Related]
18. Sensitivity correction for the influence of the fat layer on muscle oxygenation and estimation of fat thickness by time-resolved spectroscopy.
Ohmae E; Nishio S; Oda M; Suzuki H; Suzuki T; Ohashi K; Koga S; Yamashita Y; Watanabe H
J Biomed Opt; 2014 Jun; 19(6):067005. PubMed ID: 24911021
[TBL] [Abstract][Full Text] [Related]
19. Noninvasive evaluation of skeletal muscle mitochondrial capacity with near-infrared spectroscopy: correcting for blood volume changes.
Ryan TE; Erickson ML; Brizendine JT; Young HJ; McCully KK
J Appl Physiol (1985); 2012 Jul; 113(2):175-83. PubMed ID: 22582211
[TBL] [Abstract][Full Text] [Related]
20. The impact of venous occlusion per se on forearm muscle blood flow: implications for the near-infrared spectroscopy venous occlusion technique.
Cross TJ; Sabapathy S
Clin Physiol Funct Imaging; 2017 May; 37(3):293-298. PubMed ID: 26427913
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]