1. The irreplaceable image: Non-Hodgkin's lymphoma in a totally implantable subcutaneous venous access port system. Lopez-Cepero Andrada JM; Gutierrez De la Peña C; Guzmán Zamudio JL Haematologica; 2001 May; 86(5):560. PubMed ID: 11410432 [No Abstract] [Full Text] [Related]
2. Percutaneous catheters and totally implantable access systems: a review of reported infection rates. May GS; Davis C J Intraven Nurs; 1988; 11(2):97-103. PubMed ID: 3280763 [No Abstract] [Full Text] [Related]
3. [Relapse of a non-Hodgkin lymphoma in a central vein reservoir port-a-cath type]. López-Cepero Andrada JM; Gutiérrez De La Peña C; Guzmán Zamudio JL; Silva Abad A Rev Clin Esp; 2002 Aug; 202(8):464. PubMed ID: 12200002 [No Abstract] [Full Text] [Related]
4. Letter: the mechanisms of failure of totally implantable central venous access system: Analysis of 73 cases with fracture of catheter (EJSO 2010; 36:100-3). Tsai YF Eur J Surg Oncol; 2010 May; 36(5):509; author reply 510. PubMed ID: 20359844 [No Abstract] [Full Text] [Related]
5. [Central venous catheters for long-term use. Experiences with percutaneous insertion of the Hickman catheter and subcutaneous venous port]. Flaatten H; Koller ME; Sommerschild HC; Wesenberg F Tidsskr Nor Laegeforen; 1986 Oct; 106(28):2333-5, 2352. PubMed ID: 3787592 [No Abstract] [Full Text] [Related]
6. [Clinical outcome of totally implantable subcutaneous infusion port--comparison with home parenteral nutrition and chemotherapy]. Taniguchi K; Oka K; Tokuyasu N; Naka T; Kondo A; Tsujitani S; Ikeguchi M Gan To Kagaku Ryoho; 2008 Feb; 35(2):281-5. PubMed ID: 18281766 [TBL] [Abstract][Full Text] [Related]
7. [Complications after insertion of a totally implantable venous access port in patients treated with chemotherapy for head and neck squamous cell carcinoma]. Hoareau-Gruchet F; Rtail R; Sulaj H; Khirnetkina A; Reyt E; Righini CA Ann Otolaryngol Chir Cervicofac; 2009 Apr; 126(2):43-52. PubMed ID: 19324328 [TBL] [Abstract][Full Text] [Related]
8. ESPEN Guidelines on Parenteral Nutrition: central venous catheters (access, care, diagnosis and therapy of complications). Pittiruti M; Hamilton H; Biffi R; MacFie J; Pertkiewicz M; Clin Nutr; 2009 Aug; 28(4):365-77. PubMed ID: 19464090 [TBL] [Abstract][Full Text] [Related]
9. Totally implantable venous access device infections in patients with AIDS. Hellard M; Fuller A; Spelman D; Spicer WJ; Pickles R; Jenney A AIDS; 1997 Apr; 11(5):697-8. PubMed ID: 9108962 [No Abstract] [Full Text] [Related]
10. Seat belt associated central line fracture--a previously unreported complication in cystic fibrosis. Ghayyda SN; Roland D; Cade A J Cyst Fibros; 2008 Sep; 7(5):448-9. PubMed ID: 18455967 [TBL] [Abstract][Full Text] [Related]
11. Subclavian vein stenosis following totally implantable venous access device (TIVAD) implant by percutaneous approach. Case report. Di Carlo I; Fasone MA; Toro A; Castello G; Sparatore F; Cordio S G Chir; 2004; 25(11-12):417-9. PubMed ID: 15803820 [TBL] [Abstract][Full Text] [Related]
12. Editorial regarding use of modified femoral vein approach as method for implanting a totally implantable access port in patients with synchronous bilateral mastectomies (Chen et al.). Wanebo HJ J Surg Oncol; 2008 Sep; 98(3):147. PubMed ID: 18704913 [No Abstract] [Full Text] [Related]
13. Do central venous catheters have advantages over arteriovenous fistulas or grafts? Quarello F; Forneris G; Borca M; Pozzato M J Nephrol; 2006; 19(3):265-79. PubMed ID: 16874685 [TBL] [Abstract][Full Text] [Related]
16. [Totally implantable venous access ports: frequency of complications and analysis of bacterial contamination after ablation]. Barbut F; Soukouna S; Lalande V; Garcia ML; Neyme D; de Gramont A; Petit JC Pathol Biol (Paris); 2004 Dec; 52(10):566-74. PubMed ID: 15596304 [TBL] [Abstract][Full Text] [Related]
17. [Learning curve and early complications of totally implantable venous access devices: is tutoring the solution for the problem?]. Di Carlo I; Toro A; Sofia M; Fasone MA; Barbagallo F; Russello D G Chir; 2004 Apr; 25(4):146-8. PubMed ID: 15283408 [TBL] [Abstract][Full Text] [Related]
18. [Post-traumatic fracture and migration in the pulmonary artery of the catheter of a totally implantable venous access device. Unusual complication]. Iannelli A; Kianmanesh R; Msika S; Marano A; Levesque M; Grandjean M; Hay JM Minerva Chir; 2001 Jun; 56(3):303-6. PubMed ID: 11423798 [TBL] [Abstract][Full Text] [Related]
19. Late embolization of an unfractured port catheter into the heart: report of a case. Behrend M; Paboura E; Raab R Surg Today; 2002; 32(8):724-6. PubMed ID: 12181725 [TBL] [Abstract][Full Text] [Related]
20. [Totally implantable venous systems and cardiac tamponade. Apropos of a case]. Casas García MC; Casas García ML; Castro Bande M; Barros Núñez C; Martínez Salgado J Rev Esp Anestesiol Reanim; 1999 Jan; 46(1):48-9. PubMed ID: 10073086 [No Abstract] [Full Text] [Related] [Next] [New Search]