These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 11411240)

  • 1. Noise sensitivity of three surface ECG fibrillation detection algorithms.
    Jekova I; Cansell A; Dotsinsky I
    Physiol Meas; 2001 May; 22(2):287-97. PubMed ID: 11411240
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of five algorithms for the detection of ventricular fibrillation from the surface ECG.
    Jekova I
    Physiol Meas; 2000 Nov; 21(4):429-39. PubMed ID: 11110242
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhancing the accuracy of shock advisory algorithms in automated external defibrillators during ongoing cardiopulmonary resuscitation using a cascade of CNNEDs.
    Nejad MPS; Kargin V; Hajeb-M S; Hicks D; Valentine M; Chon KH
    Comput Biol Med; 2024 Apr; 172():108180. PubMed ID: 38452474
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detection of ventricular fibrillation and tachycardia from the surface ECG by a set of parameters acquired from four methods.
    Jekova I; Mitev P
    Physiol Meas; 2002 Nov; 23(4):629-34. PubMed ID: 12450264
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real time detection of ventricular fibrillation and tachycardia.
    Jekova I; Krasteva V
    Physiol Meas; 2004 Oct; 25(5):1167-78. PubMed ID: 15535182
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Shock advisory system for heart rhythm analysis during cardiopulmonary resuscitation using a single ECG input of automated external defibrillators.
    Krasteva V; Jekova I; Dotsinsky I; Didon JP
    Ann Biomed Eng; 2010 Apr; 38(4):1326-36. PubMed ID: 20069371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sequential algorithm for life threatening cardiac pathologies detection based on mean signal strength and EMD functions.
    Anas EM; Lee SY; Hasan MK
    Biomed Eng Online; 2010 Sep; 9():43. PubMed ID: 20815909
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new method without reference channels used for ventricular fibrillation detection during cardiopulmonary resuscitation.
    Yu M; Zhang G; Wu T; Li C; Wan Z; Li L; Wang C; Wang Y; Lu H; Chen F
    Australas Phys Eng Sci Med; 2016 Jun; 39(2):391-401. PubMed ID: 26831488
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sensitivity and specificity of an automated external defibrillator algorithm designed for pediatric patients.
    Atkins DL; Scott WA; Blaufox AD; Law IH; Dick M; Geheb F; Sobh J; Brewer JE
    Resuscitation; 2008 Feb; 76(2):168-74. PubMed ID: 17765384
    [TBL] [Abstract][Full Text] [Related]  

  • 10. See through ECG technology during cardiopulmonary resuscitation to analyze rhythm and predict defibrillation outcome.
    Affatato R; Li Y; Ristagno G
    Curr Opin Crit Care; 2016 Jun; 22(3):199-205. PubMed ID: 27031917
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Hardware implementation in VT/VF detection algorithms for AED (automatic external defibrillators)].
    Tchoudovski I; von Wagner G; Bolz A
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():547-9. PubMed ID: 12465232
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sequential algorithm for the detection of the shockable rhythms in electrocardiogram.
    Jeong JW; Lee IB; Song Y; Jang Y; Noh HW; Lee S
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():5082-5. PubMed ID: 23367071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rhythm discrimination during uninterrupted CPR using motion artifact reduction system.
    Berger RD; Palazzolo J; Halperin H
    Resuscitation; 2007 Oct; 75(1):145-52. PubMed ID: 17467872
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety. A statement for health professionals from the American Heart Association Task Force on Automatic External Defibrillation, Subcommittee on AED and Efficacy.
    Biomed Instrum Technol; 1997; 31(3):238-44. PubMed ID: 9181242
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [A New Algorithmic Method to Detect Ventricular Fibrillation Using Electrocardiogram Signals During Cardiopulmonary Resuscitation by Artificial Pressing].
    Wang D; Zhang G; Wan Z; Chen F; Song Z; Wang H; Gu B; Yu M; Wu T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2016 Aug; 33(4):747-54. PubMed ID: 29714916
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automated detection of shockable and non-shockable arrhythmia using novel wavelet-based ECG features.
    Sharma M; Singh S; Kumar A; San Tan R; Acharya UR
    Comput Biol Med; 2019 Dec; 115():103446. PubMed ID: 31627019
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A method to extract realistic artifacts from electrocardiogram recordings for robust algorithm testing.
    Galeotti L; Scully CG
    J Electrocardiol; 2018; 51(6S):S56-S60. PubMed ID: 30180996
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: application for automatic external defibrillators.
    Jekova I; Krasteva V
    Physiol Meas; 2005 Dec; 26(6):987-1003. PubMed ID: 16311447
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative assessment of the ventricular fibrillation detection algorithms in five semi-automatic or advisory defibrillators.
    Murray A; Clayton RH; Campbell RW
    Resuscitation; 1993 Oct; 26(2):163-72. PubMed ID: 8290810
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative assessment of shockable ECG rhythm detection algorithms in automated external defibrillators.
    Clifford AC
    Resuscitation; 1996 Oct; 32(3):217-25. PubMed ID: 8923585
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.