139 related articles for article (PubMed ID: 11417239)
1. [Cement removal with ultrasound in revision or total hip prosthesis].
Schwaller CA; Elke R
Orthopade; 2001 May; 30(5):310-6. PubMed ID: 11417239
[TBL] [Abstract][Full Text] [Related]
2. Effect of an ultrasonic device on temperatures generated in bone and on bone-cement structure.
Brooks AT; Nelson CL; Stewart CL; Skinner RA; Siems ML
J Arthroplasty; 1993 Aug; 8(4):413-8. PubMed ID: 8409994
[TBL] [Abstract][Full Text] [Related]
3. A-mode ultrasound-based intra-femoral bone cement detection and 3D reconstruction in RTHR.
Heger S; Mumme T; Sellei R; De La Fuente M; Wirtz DC; Radermacher K
Comput Aided Surg; 2007 May; 12(3):168-75. PubMed ID: 17538789
[TBL] [Abstract][Full Text] [Related]
4. Histological findings of the femoral bone after cement removal in hip revision. An experimental study of cadaver femurs with two different cement removal procedures.
Porsch M; Schmidt J
Arch Orthop Trauma Surg; 2003 Jun; 123(5):199-202. PubMed ID: 12743715
[TBL] [Abstract][Full Text] [Related]
5. Failure of total hip arthroplasty with a precoated prosthesis. 4- to 11-year results.
Dowd JE; Cha CW; Trakru S; Kim SY; Yang IH; Rubash HE
Clin Orthop Relat Res; 1998 Oct; (355):123-36. PubMed ID: 9917597
[TBL] [Abstract][Full Text] [Related]
6. Controlled perforation. A safe method of cement removal from the femoral canal.
Sydney SV; Mallory TH
Clin Orthop Relat Res; 1990 Apr; (253):168-72. PubMed ID: 2317970
[TBL] [Abstract][Full Text] [Related]
7. Cement-in-cement revision of the femoral stem: analysis of 1179 first-time revisions in the Swedish Hip Arthroplasty Register.
Cnudde PH; Kärrholm J; Rolfson O; Timperley AJ; Mohaddes M
Bone Joint J; 2017 Apr; 99-B(4 Supple B):27-32. PubMed ID: 28363891
[TBL] [Abstract][Full Text] [Related]
8. [Emission of air pollutants in removal of bone cement with ultrasound instruments in revision endoprosthetics].
Aldinger PR; Kleine H; Goebel A; Eickmann U; Breusch SJ
Biomed Tech (Berl); 2001 Oct; 46(10):287-9. PubMed ID: 11721584
[TBL] [Abstract][Full Text] [Related]
9. Ultrasonic bone cement removal efficiency in total joint arthroplasty revision: A computer tomographic-based cadaver study.
Roitzsch C; Apolle R; Jan Baldus C; Winzer R; Bellova P; Goronzy J; Hoffmann RT; Troost EGC; May CA; Günther KP; Fedders D; Stiehler M
J Orthop Res; 2023 Jun; 41(6):1365-1375. PubMed ID: 36222474
[TBL] [Abstract][Full Text] [Related]
10. Segmental cement extraction at revision total hip arthroplasty.
Schurman DJ; Maloney WJ
Clin Orthop Relat Res; 1992 Dec; (285):158-63. PubMed ID: 1446433
[TBL] [Abstract][Full Text] [Related]
11. [Modified intracorporeal lithotripsy for cement removal in hip prosthesis exchange operations--experimental principles].
Schmidt J; Porsch M; Hackenbroch MH; Koebke J; Brimmers P
Z Orthop Ihre Grenzgeb; 1998; 136(1):44-9. PubMed ID: 9563186
[TBL] [Abstract][Full Text] [Related]
12. Revision of the cemented femoral stem using a cement-in-cement technique: a five- to 15-year review.
Duncan WW; Hubble MJ; Howell JR; Whitehouse SL; Timperley AJ; Gie GA
J Bone Joint Surg Br; 2009 May; 91(5):577-82. PubMed ID: 19407288
[TBL] [Abstract][Full Text] [Related]
13. Computer-assisted fluoroscopic navigation system for removal of distal femoral bone cement in revision total hip arthroplasty.
Akiyama H; Kawanabe K; Goto K; Ohnishi E; Nakamura T
J Arthroplasty; 2007 Apr; 22(3):445-8. PubMed ID: 17400101
[TBL] [Abstract][Full Text] [Related]
14. Ultrasonic cement removal in revision arthroplasty.
Goldberg SH; Studders EM; Cohen MS
Orthopedics; 2007 Aug; 30(8):632-5. PubMed ID: 17727019
[TBL] [Abstract][Full Text] [Related]
15. Femoral cement extraction in revision total hip arthroplasty--an in vitro study comparing computer-assisted freehand-navigated cement removal to conventional cement extraction.
Mumme T; Friedrich MJ; Rode H; Gravius S; Andereya S; Müller-Rath R; de la Fuente M
Biomed Tech (Berl); 2015 Dec; 60(6):567-75. PubMed ID: 26053005
[TBL] [Abstract][Full Text] [Related]
16. Total hip revision arthroplasty. Prosthesis and cement removal techniques.
Gray FB
Orthop Clin North Am; 1992 Apr; 23(2):313-9. PubMed ID: 1570143
[TBL] [Abstract][Full Text] [Related]
17. [Cement removal in changing hip prosthesis implants. Search for a conservative method].
Schmidt J; Mittelmeier W; Porsch M
MMW Fortschr Med; 1999 Jul; 141(26):45-6. PubMed ID: 10897929
[No Abstract] [Full Text] [Related]
18. Scanning electron microscopy investigation of PMMA removal by laser irradiation (Er:YAG) in comparison with an ultrasonic system and curettage in hip joint revision arthroplasty.
Birnbaum K; Gutknecht N
Lasers Med Sci; 2010 Jul; 25(4):595-603. PubMed ID: 20354888
[TBL] [Abstract][Full Text] [Related]
19. Recementing a femoral component into a stable cement mantle using ultrasonic tools.
McCallum JD; Hozack WJ
Clin Orthop Relat Res; 1995 Oct; (319):232-7. PubMed ID: 7554635
[TBL] [Abstract][Full Text] [Related]
20. [Technical principles for removal of femoral bone cements in hip prosthesis implant revision].
Lauer W; Neuss M; Wirtz DC; Radermacher K
Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():47-8. PubMed ID: 12451769
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]