152 related articles for article (PubMed ID: 11419634)
1. Temperature measurement artefacts of thermocouples and fluoroptic probes during laser irradiation at 810 nm.
Reid AD; Gertner MR; Sherar MD
Phys Med Biol; 2001 Jun; 46(6):N149-57. PubMed ID: 11419634
[TBL] [Abstract][Full Text] [Related]
2. Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm.
Davidson SR; Vitkin IA; Sherar MD; Whelan WM
Lasers Surg Med; 2005 Apr; 36(4):297-306. PubMed ID: 15786482
[TBL] [Abstract][Full Text] [Related]
3. The influence of Nd:YAG laser irradiation on Fluoroptic® temperature measurement: an experimental evaluation.
Hübner F; Bazrafshan B; Roland J; Kickhefel A; Vogl TJ
Lasers Med Sci; 2013 Feb; 28(2):487-96. PubMed ID: 22476531
[TBL] [Abstract][Full Text] [Related]
4. In situ temperature measurements with thermocouple probes during laser interstitial thermotherapy (LITT): quantification and correction of a measurement artifact.
Manns F; Milne PJ; Gonzalez-Cirre X; Denham DB; Parel JM; Robinson DS
Lasers Surg Med; 1998; 23(2):94-103. PubMed ID: 9738544
[TBL] [Abstract][Full Text] [Related]
5. Artefacts in intracavitary temperature measurements during regional hyperthermia.
Kok HP; Van den Berg CA; Van Haaren PM; Crezee J
Phys Med Biol; 2007 Sep; 52(17):5157-71. PubMed ID: 17762078
[TBL] [Abstract][Full Text] [Related]
6. Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic probes.
Mattei E; Triventi M; Calcagnini G; Censi F; Kainz W; Bassen HI; Bartolini P
Phys Med Biol; 2007 Mar; 52(6):1633-46. PubMed ID: 17327653
[TBL] [Abstract][Full Text] [Related]
7. Effect of diode lasers with wavelength of 445 and 980 nm on a temperature rise when uncovering implants for second stage surgery: An ex-vivo study in pigs.
Matys J; Flieger R; Dominiak M
Adv Clin Exp Med; 2017 Jul; 26(4):687-693. PubMed ID: 28691432
[TBL] [Abstract][Full Text] [Related]
8. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
[TBL] [Abstract][Full Text] [Related]
9. Assessment of temperature measurement error and its correction during Nd:YAG laser ablation in porcine pancreas.
Schena E; Majocchi L
Int J Hyperthermia; 2014 Aug; 30(5):328-34. PubMed ID: 25010146
[TBL] [Abstract][Full Text] [Related]
10. Temperature change during non-contact diode laser irradiation of implant surfaces.
Geminiani A; Caton JG; Romanos GE
Lasers Med Sci; 2012 Mar; 27(2):339-42. PubMed ID: 21274734
[TBL] [Abstract][Full Text] [Related]
11. Implementation of a multisource model for gold nanoparticle-mediated plasmonic heating with near-infrared laser by the finite element method.
Reynoso FJ; Lee CD; Cheong SK; Cho SH
Med Phys; 2013 Jul; 40(7):073301. PubMed ID: 23822455
[TBL] [Abstract][Full Text] [Related]
12. Thermal characteristics of sapphire contact probe delivery systems for laser angioplasty.
Ashley S; Brooks SG; Gehani AA; Kester RC; Rees MR
Lasers Surg Med; 1990; 10(3):234-44. PubMed ID: 2345473
[TBL] [Abstract][Full Text] [Related]
13. Laser probe temperature control by measuring the returning infra-red radiation.
Torres JH; Ghaffari S; Welch AJ
Med Biol Eng Comput; 1990 Jan; 28(1):1-7. PubMed ID: 2325445
[TBL] [Abstract][Full Text] [Related]
14. Root Surface Temperature Changes During Root Canal Laser Irradiation with Dual Wavelength Laser (940 and 2780 nm): A Preliminary Study.
Haidary D; Franzen R; Gutknecht N
Photomed Laser Surg; 2016 Aug; 34(8):336-44. PubMed ID: 27294503
[TBL] [Abstract][Full Text] [Related]
15. Comparative Evaluations on Real-Time Monitoring of Temperature Sensors during Endoscopic Laser Application.
Ta MD; Truong VG; Lim S; Lee BI; Kang HW
Sensors (Basel); 2023 Jun; 23(13):. PubMed ID: 37447918
[TBL] [Abstract][Full Text] [Related]
16. Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model.
Rodríguez I; Lequerica JL; Berjano EJ; Herrero M; Hornero F
Physiol Meas; 2007 May; 28(5):453-63. PubMed ID: 17470980
[TBL] [Abstract][Full Text] [Related]
17. Thermodynamic Effects of 3 Different Diode Lasers on an Implant-Bone Interface: An Ex-Vivo Study With Review of the Literature.
Valente NA; Calascibetta A; Patianna G; Mang T; Hatton M; Andreana S
J Oral Implantol; 2017 Apr; 43(2):94-99. PubMed ID: 28001482
[TBL] [Abstract][Full Text] [Related]
18. Temperature along the surface of modified fiber tips for Nd:YAG laser angioplasty.
Verdaasdonk RM; Holstege FC; Jansen ED; Borst C
Lasers Surg Med; 1991; 11(3):213-22. PubMed ID: 1861560
[TBL] [Abstract][Full Text] [Related]
19. Thermal Effects of Diode Laser-Irradiation on Titanium Implants in Different Room Temperatures
Hafeez M; Calce L; Hong H; Hou W; Romanos GE
Photobiomodul Photomed Laser Surg; 2022 Aug; 40(8):554-558. PubMed ID: 35960815
[No Abstract] [Full Text] [Related]
20. Characterization of the RF ablation-induced 'oven effect': the importance of background tissue thermal conductivity on tissue heating.
Liu Z; Ahmed M; Weinstein Y; Yi M; Mahajan RL; Goldberg SN
Int J Hyperthermia; 2006 Jun; 22(4):327-42. PubMed ID: 16754353
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]