These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 11420326)

  • 1. Foot length, an accurate predictor of nasotracheal tube length in neonates.
    Embleton ND; Deshpande SA; Scott D; Wright C; Milligan DW
    Arch Dis Child Fetal Neonatal Ed; 2001 Jul; 85(1):F60-4. PubMed ID: 11420326
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-Dimensional Imaging-Based Web Application for Predicting Tracheal Tube Depth in Preterm Neonates.
    Tupprasoot R; Langan D; Hutchinson JC; Barrett H; Sury MRJ; Arthurs OJ
    Neonatology; 2017; 111(4):376-382. PubMed ID: 28142138
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal positioning of endotracheal tubes for ventilation of preterm infants.
    Rotschild A; Chitayat D; Puterman ML; Phang MS; Ling E; Baldwin V
    Am J Dis Child; 1991 Sep; 145(9):1007-12. PubMed ID: 1877557
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nasotracheal intubation depth in paediatric patients.
    Kemper M; Dullenkopf A; Schmidt AR; Gerber A; Weiss M
    Br J Anaesth; 2014 Nov; 113(5):840-6. PubMed ID: 25085459
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Estimation of the optimal tube length : Systematic review article on published formulae for infants and children].
    Boensch M; Schick V; Spelten O; Hinkelbein J
    Anaesthesist; 2016 Feb; 65(2):115-21. PubMed ID: 26696266
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal Insertion Depth for Endotracheal Tubes in Extremely Low-Birth-Weight Infants.
    Leung C
    Pediatr Crit Care Med; 2018 Apr; 19(4):328-331. PubMed ID: 29406381
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid estimation of insertional length of endotracheal intubation in newborn infants.
    Shukla HK; Hendricks-Munoz KD; Atakent Y; Rapaport S
    J Pediatr; 1997 Oct; 131(4):561-4. PubMed ID: 9386659
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Oro-Helical Length Accurately Predicts Endotracheal Tube Insertion Depth in Neonates.
    Lee D; Mele PC; Hou W; Decristofaro JD; Maduekwe ET
    J Pediatr; 2018 Sep; 200():265-269.e2. PubMed ID: 29803303
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Distances from vocal cords to mid-trachea for optimizing endotracheal tubes depth markers according to gestational age.
    Rigo V; Fayoux P
    Paediatr Anaesth; 2018 Apr; 28(4):361-366. PubMed ID: 29484763
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of body parameters for estimation of endotracheal tube length in Indian neonates.
    Tatwavedi D; Nesargi SV; Shankar N; Rao S; Bhat SR
    Eur J Pediatr; 2015 Feb; 174(2):245-9. PubMed ID: 25084972
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prediction of appropriate formula for nasotracheal tube size in developmental disability children.
    Tsukamoto M; Taura S; Yamanaka H; Hitosugi T; Yokoyama T
    Clin Oral Investig; 2021 Apr; 25(4):2077-2080. PubMed ID: 32804259
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cuffed endotracheal tubes in infants less than 3 kg: A retrospective cohort study.
    Thomas RE; Rao SC; Minutillo C; Hullett B; Bulsara MK
    Paediatr Anaesth; 2018 Mar; 28(3):204-209. PubMed ID: 29315968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimation of Optimal Nasotracheal Tube Insertion Depth in Neonates Based on Fetal Biometric Measurements.
    Selter M; Deindl P; Wolf M; Herrmann J; Hecher K; Singer D; Ebenebe CU
    Neonatology; 2022; 119(3):397-401. PubMed ID: 35193140
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New formulae for predicting tracheal tube length.
    Lau N; Playfor SD; Rashid A; Dhanarass M
    Paediatr Anaesth; 2006 Dec; 16(12):1238-43. PubMed ID: 17121553
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical audit: optimal positioning of endotracheal tubes in neonates.
    Whyte KL; Levin R; Powls A
    Scott Med J; 2007 May; 52(2):25-7. PubMed ID: 17536638
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Estimation of a suitable nasotracheal tube length for infants and children.
    Mattila MA; Heikel PE; Suutarinen T; Lindfors EL
    Acta Anaesthesiol Scand; 1971 Dec; 15(4):239-46. PubMed ID: 5155399
    [No Abstract]   [Full Text] [Related]  

  • 17. Accuracy of various recent recommendations to estimate the optimal depth of orotracheal tube in Thai neonates.
    Puttawong D; Manopunya S; Visrutaratna P; Kosarat S; Khuwuthyakorn V; Tantiprabha W
    J Matern Fetal Neonatal Med; 2022 Sep; 35(17):3343-3347. PubMed ID: 32928006
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Foot length, chest and head circumference measurements in detection of Low birth weight neonates in Mekelle, Ethiopia: a hospital based cross sectional study.
    Hadush MY; Berhe AH; Medhanyie AA
    BMC Pediatr; 2017 Apr; 17(1):111. PubMed ID: 28431500
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Normative Data of Optimally Placed Endotracheal Tube by Point-of-care Ultrasound in Neonates.
    Singh P; Thakur A; Garg P; Aggarwal N; Kler N
    Indian Pediatr; 2019 May; 56(5):374-380. PubMed ID: 31102379
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Radiographic assessment of accuracy of tracheal tube placement in children].
    Nowicka M; Kurczabińska-Luboń D; Stołtny L; Luboń D; Gój K
    Anestezjol Intens Ter; 2008; 40(2):70-4. PubMed ID: 19469102
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.