These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Comparison of different techniques of hemodialysis vascular access flow evaluation. Lopot F; Nejedlý B; Sulková S; Bláha J Int J Artif Organs; 2003 Dec; 26(12):1056-63. PubMed ID: 14738189 [TBL] [Abstract][Full Text] [Related]
6. Clinical validation of glucose pump test (GPT) compared with ultrasound dilution technology in arteriovenous graft surveillance. Magnasco A; Bacchini G; Cappello A; La Milia V; Brezzi B; Messa P; Locatelli F Nephrol Dial Transplant; 2004 Jul; 19(7):1835-41. PubMed ID: 15161950 [TBL] [Abstract][Full Text] [Related]
7. Determination of access blood flow from ionic dialysance: theory and validation. Mercadal L; Hamani A; Béné B; Petitclerc T Kidney Int; 1999 Oct; 56(4):1560-5. PubMed ID: 10504508 [TBL] [Abstract][Full Text] [Related]
8. [Clinical and instrumental surveillance of the arteriovenous fistula]. Quarello F; Forneris G; Pozzato M G Ital Nefrol; 2004; 21(4):317-30. PubMed ID: 15470658 [TBL] [Abstract][Full Text] [Related]
9. Comparison between two on-line reversed line position hemodialysis vascular access flow measurement techniques: saline dilution and thermodilution. Wijnen E; Essers S; van Meijel G; Kooman JP; Tordoir J; Leunissen KM; van der Sande FM ASAIO J; 2006; 52(4):410-5. PubMed ID: 16883121 [TBL] [Abstract][Full Text] [Related]
10. A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate. Lindsay RM; Bradfield E; Rothera C; Kianfar C; Malek P; Blake PG ASAIO J; 1998; 44(1):62-7. PubMed ID: 9466503 [TBL] [Abstract][Full Text] [Related]
11. Glucose infusion test (GIT) compared with the saline dilution technology in recirculation measurements. Magnasco A; Alloatti S Nephrol Dial Transplant; 2006 Nov; 21(11):3180-4. PubMed ID: 16891645 [TBL] [Abstract][Full Text] [Related]
12. Access flow measured during hemodialysis. Sands J; Glidden D; Miranda C ASAIO J; 1996; 42(5):M530-2. PubMed ID: 8944935 [TBL] [Abstract][Full Text] [Related]
13. Noninvasive transcutaneous access flow measurement before and after hemodialysis: impact of hematocrit and blood pressure. Ronco C; Brendolan A; Crepaldi C; D'Intini V; Sergeyeva O; Levin NW Blood Purif; 2002; 20(4):376-9. PubMed ID: 12169848 [TBL] [Abstract][Full Text] [Related]
14. Study of arteriovenous fistula function by the temperature gradient method using the Twister™ device. Roca-Tey R; Samon R; Ibrik O; Roda A; González-Oliva JC; Viladoms J Nefrologia; 2012; 32(2):172-9. PubMed ID: 22425797 [TBL] [Abstract][Full Text] [Related]
15. Glucose pump test: a new method for blood flow measurements. Magnasco A; Alloatti S; Martinoli C; Solari P Nephrol Dial Transplant; 2002 Dec; 17(12):2244-8. PubMed ID: 12454240 [TBL] [Abstract][Full Text] [Related]