These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 11425073)

  • 1. Biomechanical evaluation of two halo pin designs, with, and without, intact periosteum.
    Bullock SJ; Runciman RJ
    J Biomech; 2001 Jan; 34(1):129-33. PubMed ID: 11425073
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Halo pin loosening: a biomechanical comparison of experimental and conventional designs.
    Voor MJ; Khalily C
    J Biomech; 1998 Apr; 31(4):397-400. PubMed ID: 9672096
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative evaluation of halo pin designs in an immature skull model.
    Copley LA; Pepe MD; Tan V; Dormans JP; Gabriel JP; Sheth NP; Asada N
    Clin Orthop Relat Res; 1998 Dec; (357):212-8. PubMed ID: 9917719
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of various angles of halo pin insertion in an immature skull model.
    Copley LA; Pepe MD; Tan V; Sheth N; Dormans JP
    Spine (Phila Pa 1976); 1999 Sep; 24(17):1777-80. PubMed ID: 10488506
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of pin location on the rigidity of the halo pin-bone interface.
    Ballock RT; Lee TQ; Triggs KJ; Woo SL; Garfin SR
    Neurosurgery; 1990 Feb; 26(2):238-41. PubMed ID: 2308671
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method of tightening halo orthosis pins that reduces initial pin force variation.
    Klingenberg J; Keown A; Moser D; Neal T; Stamper R
    Biomed Sci Instrum; 2002; 38():245-50. PubMed ID: 12085610
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of minimum required halo pin force.
    Karnes J; Moench K; Ordway NR; Stamper R; Trammell T
    J Spinal Disord Tech; 2006 Jun; 19(4):281-5. PubMed ID: 16778664
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of pin force distributions of halo orthoses.
    Kuester WM; Stamper RE; Ordway NR
    Biomed Sci Instrum; 2002; 38():221-6. PubMed ID: 12085606
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Structural behavior of the halo orthosis pin-bone interface: biomechanical evaluation of standard and newly designed stainless steel halo fixation pins.
    Garfin SR; Lee TQ; Roux RD; Silva FW; Ballock RT; Botte MJ; Katz MM; Woo SL
    Spine (Phila Pa 1976); 1986 Dec; 11(10):977-81. PubMed ID: 3576346
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pin loosening in a halo-vest orthosis: a biomechanical study.
    Fleming BC; Krag MH; Huston DR; Sugihara S
    Spine (Phila Pa 1976); 2000 Jun; 25(11):1325-31. PubMed ID: 10828912
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Six-pin halo fixation and the resulting prevalence of pin-site complications.
    Nemeth JA; Mattingly LG
    J Bone Joint Surg Am; 2001 Mar; 83(3):377-82. PubMed ID: 11263641
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pin force measurement in a halo-vest orthosis, in vivo.
    Fleming BC; Huston DR; Krag MH; Sugihara S
    J Biomech; 1998 Jul; 31(7):647-51. PubMed ID: 9796687
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical evaluation of fetal calf skull as a model for testing halo-pin designs for use in children.
    Beall MS; Copley LA; Niemann JJ; Lankachandra K; Williams JL
    J Biomech; 2007; 40(5):1137-44. PubMed ID: 16797557
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does routine pin re-torquing of patients wearing a halo-thoracic orthosis reduce the need for pin replacement?
    Fraser S; Coffey JP
    Prosthet Orthot Int; 2015 Aug; 39(4):338-41. PubMed ID: 24812117
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A biomechanical study of torque and accuracy of halo pin insertional devices.
    Smith MD; Johnson LJ; Perra JH; Rawlins BA
    J Bone Joint Surg Am; 1996 Feb; 78(2):231-8. PubMed ID: 8609114
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Halo pin intracranial penetration and epidural abscess in a patient with a previous cranioplasty: case report and review of the literature.
    Papagelopoulos PJ; Sapkas GS; Kateros KT; Papadakis SA; Vlamis JA; Falagas ME
    Spine (Phila Pa 1976); 2001 Oct; 26(19):E463-7. PubMed ID: 11698907
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of angled insertion on halo pin fixation.
    Triggs KJ; Ballock RT; Lee TQ; Woo SL; Garfin SR
    Spine (Phila Pa 1976); 1989 Aug; 14(8):781-3. PubMed ID: 2781390
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reverse Anterior Cruciate Ligament Reconstruction Fixation: A Biomechanical Comparison Study of Tibial Cross-Pin and Femoral Interference Screw Fixation.
    Lawley RJ; Klein SE; Chudik SC
    Arthroscopy; 2017 Mar; 33(3):625-632. PubMed ID: 27939069
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Kinematic constraint analysis of halo orthoses.
    Stamper RE; Kuester WM
    Biomed Sci Instrum; 2001; 37():173-8. PubMed ID: 11347383
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Halo pin positioning in the temporal bone; parameters for safe halo gravity traction.
    Semmelink K; Hekman EEG; van Griethuysen M; Bosma J; Swaan A; Kruyt MC
    Spine Deform; 2021 Jan; 9(1):255-261. PubMed ID: 32915397
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.