These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 11439474)

  • 21. Fan-beam filtered-backprojection reconstruction without backprojection weight.
    Dennerlein F; Noo F; Hornegger J; Lauritsch G
    Phys Med Biol; 2007 Jun; 52(11):3227-40. PubMed ID: 17505099
    [TBL] [Abstract][Full Text] [Related]  

  • 22. View-independent reconstruction algorithms for cone beam CT with general saddle trajectory.
    Yang H; Li M; Koizumi K; Kudo H
    Phys Med Biol; 2006 Aug; 51(15):3865-84. PubMed ID: 16861786
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A filtered backprojection algorithm with ray-by-ray noise weighting.
    Zeng GL; Zamyatin A
    Med Phys; 2013 Mar; 40(3):031113. PubMed ID: 23464293
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Hilbert transform based FBP algorithm for fan-beam CT full and partial scans.
    You J; Zeng GL
    IEEE Trans Med Imaging; 2007 Feb; 26(2):190-9. PubMed ID: 17304733
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Exact and approximate algorithms for helical cone-beam CT.
    Kudo H; Rodet T; Noo F; Defrise M
    Phys Med Biol; 2004 Jul; 49(13):2913-31. PubMed ID: 15285256
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cone-beam image reconstruction using spherical harmonics.
    Taguchi K; Zeng GL; Gullberg GT
    Phys Med Biol; 2001 Jun; 46(6):N127-38. PubMed ID: 11419632
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Laplace operator based reconstruction algorithm for truncated spiral cone beam computed tomography.
    Zou X; Yu H; Zeng L
    J Xray Sci Technol; 2013; 21(4):515-26. PubMed ID: 24191989
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Image reconstruction for the circle-and-arc trajectory.
    Katsevich A
    Phys Med Biol; 2005 May; 50(10):2249-65. PubMed ID: 15876665
    [TBL] [Abstract][Full Text] [Related]  

  • 29. PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.
    Zou Y; Pan X; Xia D; Wang G
    Med Phys; 2005 Aug; 32(8):2639-48. PubMed ID: 16193794
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Spatial resolution improvement and dose reduction potential for inner ear CT imaging using a z-axis deconvolution technique.
    McCollough CH; Leng S; Sunnegardh J; Vrieze TJ; Yu L; Lane J; Raupach R; Stierstorfer K; Flohr T
    Med Phys; 2013 Jun; 40(6):061904. PubMed ID: 23718595
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analytic reconstruction approach for parallel translational computed tomography.
    Kong H; Yu H
    J Xray Sci Technol; 2015; 23(2):213-28. PubMed ID: 25882732
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Filtered Backprojection Reconstruction with Depth-Dependent Filtering.
    Dennerlein F; Kunze H; Noo F
    Tsinghua Sci Technol; 2010 Feb; 15(1):17-24. PubMed ID: 20585466
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Determining the radiation dose reduction potential for coronary calcium scanning with computed tomography: an anthropomorphic phantom study comparing filtered backprojection and the adaptive iterative dose reduction algorithm for image reconstruction.
    Blobel J; Mews J; Schuijf JD; Overlaet W
    Invest Radiol; 2013 Dec; 48(12):857-62. PubMed ID: 23917328
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A three-dimensional reconstruction algorithm for an inverse-geometry volumetric CT system.
    Schmidt TG; Fahrig R; Pelc NJ
    Med Phys; 2005 Nov; 32(11):3234-45. PubMed ID: 16370414
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage.
    Kachelriess M; Knaup M; Kalender WA
    Med Phys; 2004 Jun; 31(6):1623-41. PubMed ID: 15259667
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
    Qi Z; Chen GH
    Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Fast reconstruction of flat region in a super-short scan based on MD-FBP algorithm.
    Wang X; Li L; Yu C; Yan B; Bao S
    J Xray Sci Technol; 2012; 20(1):69-77. PubMed ID: 22398588
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.
    Wang J; Lu H; Li T; Liang Z
    Med Phys; 2005 Nov; 32(11):3389-94. PubMed ID: 16372414
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Extending Three-Dimensional Weighted Cone Beam Filtered Backprojection (CB-FBP) Algorithm for Image Reconstruction in Volumetric CT at Low Helical Pitches.
    Tang X; Hsieh J; Nilsen RA; McOlash SM
    Int J Biomed Imaging; 2006; 2006():45942. PubMed ID: 23165031
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window.
    Yu H; Ye Y; Zhao S; Wang G
    Phys Med Biol; 2005 May; 50(9):2099-111. PubMed ID: 15843739
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.