These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 11443393)

  • 1. Dilatation of stent-grafts by luminal pressures: experimental evaluation of polytetrafluoroethylene (PTFE) and woven polyester grafts.
    Suzuki K; Ishiguchi T; Kawatsu S; Iwai H; Maruyama K; Ishigaki T
    Cardiovasc Intervent Radiol; 2001; 24(2):94-8. PubMed ID: 11443393
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of transjugular intrahepatic portosystemic shunt dysfunction in PTFE-covered stent-grafts versus bare stents.
    Barrio J; Ripoll C; Bañares R; Echenagusia A; Catalina MV; Camúñez F; Simó G; Santos L
    Eur J Radiol; 2005 Jul; 55(1):120-4. PubMed ID: 15950109
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [In vitro evaluation of blood vessel prosthesis dilatation--Dacron and PTFE--a new measuring technique].
    Shekarriz H; Wenk H; Müller G; Bruch HP
    Zentralbl Chir; 1997; 122(9):805-8. PubMed ID: 9454492
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: the Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial.
    Stankovic G; Colombo A; Presbitero P; van den Branden F; Inglese L; Cernigliaro C; Niccoli L; Bartorelli AL; Rubartelli P; Reifart N; Heyndrickx GR; Saunamäki K; Morice MC; Sgura FA; Di Mario C;
    Circulation; 2003 Jul; 108(1):37-42. PubMed ID: 12821546
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evidence suggests rigid aortic grafts increase systolic blood pressure: results of a preliminary study.
    O'Brien T; Morris L; McGloughlin T
    Med Eng Phys; 2008 Jan; 30(1):109-15. PubMed ID: 17360221
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Platelet adhesion in polytetrafluoroethylene (PTFE) vascular grafts in vivo and the influence of increased intramuscular pressure--an experimental model.
    Christenson JT; Qvarfordt P; Strand SE; Arvidsson D; Sjöberg T; Olsson PI
    Thromb Haemost; 1983 Dec; 50(4):881-4. PubMed ID: 6420926
    [TBL] [Abstract][Full Text] [Related]  

  • 7. One-year outcomes for recanalization of long superficial femoral artery chronic total occlusions with the Viabahn stent graft.
    Farraj N; Srivastava A; Pershad A
    J Invasive Cardiol; 2009 Jun; 21(6):278-81. PubMed ID: 19494404
    [TBL] [Abstract][Full Text] [Related]  

  • 8. External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.
    Klesius AA; Konerding MA; Knez P; Dzemali O; Schmitz-Rixen T; Ackermann H; Moritz A; Kleine P
    Int J Artif Organs; 2007 Oct; 30(10):930-8. PubMed ID: 17992655
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An investigation into the cause of distal endoleaks: role of displacement force on the distal end of a stent-graft.
    Volodos SM; Sayers RD; Gostelow JP; Sir Bell PR
    J Endovasc Ther; 2005 Feb; 12(1):115-20. PubMed ID: 15683261
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro fenestration of aortic stent-grafts: implications of puncture methods for in situ fenestration durability.
    Riga CV; Bicknell CD; Basra M; Hamady M; Cheshire NJ
    J Endovasc Ther; 2013 Aug; 20(4):536-43. PubMed ID: 23914863
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dilatation of aortic grafts over time: what to expect and when to be concerned.
    Schroeder TV; Eldrup N; Just S; Hansen M; Nyhuus B; Sillesen H
    Semin Vasc Surg; 2009 Jun; 22(2):119-24. PubMed ID: 19573752
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endovascular grafting of complex aortic aneurysms with a modular side branch stent-graft system in a porcine model.
    Vos AW; Linsen MA; Wisselink W; Rauwerda JA
    Eur J Vasc Endovasc Surg; 2004 May; 27(5):492-7. PubMed ID: 15079771
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Failure of the Symbiot PTFE-covered stent to reduce distal embolization during percutaneous coronary intervention in saphenous vein grafts.
    Blackman DJ; Choudhury RP; Banning AP; Channon KM
    J Invasive Cardiol; 2005 Nov; 17(11):609-12. PubMed ID: 16264208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PTFE-covered stents improve TIPS patency in Budd-Chiari syndrome.
    Hernández-Guerra M; Turnes J; Rubinstein P; Olliff S; Elias E; Bosch J; García-Pagán JC
    Hepatology; 2004 Nov; 40(5):1197-202. PubMed ID: 15486923
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Collagen versus gelatin-coated Dacron versus stretch polytetrafluoroethylene in abdominal aortic bifurcation graft surgery: results of a seven-year prospective, randomized multicenter trial.
    Prager M; Polterauer P; Böhmig HJ; Wagner O; Fügl A; Kretschmer G; Plohner M; Nanobashvili J; Huk I
    Surgery; 2001 Sep; 130(3):408-14. PubMed ID: 11562661
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Custom-made stent-grafts for aortic aneurysm repair using gianturco Z stents and woven polyester: healing in an animal model.
    Koskas F; Brocheriou I; Cluzel P; Singland JD; Régnier B; Bonnot M; Kieffer E
    Vasc Endovascular Surg; 2005; 39(1):55-65. PubMed ID: 15696249
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polytetrafluoroethylene-covered stents in the venous and arterial system: angiographic and pathologic findings in a swine model.
    Gordon BM; Fishbein MC; Levi DS
    Cardiovasc Pathol; 2008; 17(4):206-11. PubMed ID: 18402810
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Protection of saphenous vein graft from arterial pressure: an experimental study.
    Kurdal AT; Ustundag N; Güven A; Iskesen I; Bozkurt K; Sirin BH
    Thorac Cardiovasc Surg; 2009 Sep; 57(6):333-8. PubMed ID: 19707974
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical characteristics of dilated polytetraflouroethylene used for transluminally placed endovascular grafts.
    Marston WA; Risley GL; Criado E; McHugh P; Reddick RL; Woosley JT; Keagy BA
    Ann Vasc Surg; 1997 Jan; 11(1):68-73. PubMed ID: 9061142
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Enhanced strength of endothelial attachment on polyester elastomer and polytetrafluoroethylene graft surfaces with fibronectin substrate.
    Kesler KA; Herring MB; Arnold MP; Glover JL; Park HM; Helmus MN; Bendick PJ
    J Vasc Surg; 1986 Jan; 3(1):58-64. PubMed ID: 3079841
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.