82 related articles for article (PubMed ID: 11450549)
1. [Study on the noninvasive measurement of cerebral oxygen saturation and cerebral phronetal function].
Yao P; Li S; Zhang A; Liu Y; Xu M; Jin T
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Jun; 18(2):260-4. PubMed ID: 11450549
[TBL] [Abstract][Full Text] [Related]
2. Near-infrared spectroscopic cerebral oxygenation reading in neonates and infants is associated with central venous oxygen saturation.
Weiss M; Dullenkopf A; Kolarova A; Schulz G; Frey B; Baenziger O
Paediatr Anaesth; 2005 Feb; 15(2):102-9. PubMed ID: 15675925
[TBL] [Abstract][Full Text] [Related]
3. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.
Tortoriello TA; Stayer SA; Mott AR; McKenzie ED; Fraser CD; Andropoulos DB; Chang AC
Paediatr Anaesth; 2005 Jun; 15(6):495-503. PubMed ID: 15910351
[TBL] [Abstract][Full Text] [Related]
4. Cerebral near-infrared spectroscopy in adult patients after cardiac surgery is not useful for monitoring absolute values but may reflect trends in venous oxygenation under clinical conditions.
Dullenkopf A; Baulig W; Weiss M; Schmid ER
J Cardiothorac Vasc Anesth; 2007 Aug; 21(4):535-9. PubMed ID: 17678780
[TBL] [Abstract][Full Text] [Related]
5. Near-infrared spectroscopy (NIRS) in cognitive neuroscience of the primate brain.
Fuster J; Guiou M; Ardestani A; Cannestra A; Sheth S; Zhou YD; Toga A; Bodner M
Neuroimage; 2005 May; 26(1):215-20. PubMed ID: 15862221
[TBL] [Abstract][Full Text] [Related]
6. [An index of cerebral perfusion: noninvasive monitoring of regional cerebral oxygen saturation by use of near-infrared spectroscopy (NIRS, NIRO) or NIRS cerebral oximetry (INVOS)].
Nishikawa T
Masui; 2009 Jul; 58(7):866-71. PubMed ID: 19618828
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.
Moritz S; Kasprzak P; Arlt M; Taeger K; Metz C
Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451
[TBL] [Abstract][Full Text] [Related]
8. Measuring brain hemodynamic changes in a songbird: responses to hypercapnia measured with functional MRI and near-infrared spectroscopy.
Vignal C; Boumans T; Montcel B; Ramstein S; Verhoye M; Van Audekerke J; Mathevon N; Van der Linden A; Mottin S
Phys Med Biol; 2008 May; 53(10):2457-70. PubMed ID: 18424882
[TBL] [Abstract][Full Text] [Related]
9. Regional cerebral saturation monitoring with near-infrared spectroscopy during selective antegrade cerebral perfusion: diagnostic performance and relationship to postoperative stroke.
Olsson C; Thelin S
J Thorac Cardiovasc Surg; 2006 Feb; 131(2):371-9. PubMed ID: 16434267
[TBL] [Abstract][Full Text] [Related]
10. Near-infrared spectroscopy correlates with continuous superior vena cava oxygen saturation in pediatric cardiac surgery patients.
Ranucci M; Isgrò G; De la Torre T; Romitti F; Conti D; Carlucci C
Paediatr Anaesth; 2008 Dec; 18(12):1163-9. PubMed ID: 19076569
[TBL] [Abstract][Full Text] [Related]
11. Assessment of cerebral oxygen balance during deep hypothermic circulatory arrest by continuous jugular bulb venous saturation and near-infrared spectroscopy.
Leyvi G; Bello R; Wasnick JD; Plestis K
J Cardiothorac Vasc Anesth; 2006 Dec; 20(6):826-33. PubMed ID: 17138088
[TBL] [Abstract][Full Text] [Related]
12. Novel cerebral physiologic monitoring to guide low-flow cerebral perfusion during neonatal aortic arch reconstruction.
Andropoulos DB; Stayer SA; McKenzie ED; Fraser CD
J Thorac Cardiovasc Surg; 2003 Mar; 125(3):491-9. PubMed ID: 12658190
[TBL] [Abstract][Full Text] [Related]
13. Regional differences in tissue oxygenation during cardiopulmonary bypass for correction of congenital heart disease in neonates and small infants: relevance of near-infrared spectroscopy.
Redlin M; Koster A; Huebler M; Boettcher W; Nagdyman N; Hetzer R; Kuppe H; Kuebler WM
J Thorac Cardiovasc Surg; 2008 Oct; 136(4):962-7. PubMed ID: 18954637
[TBL] [Abstract][Full Text] [Related]
14. A proposed algorithm for the intraoperative use of cerebral near-infrared spectroscopy.
Denault A; Deschamps A; Murkin JM
Semin Cardiothorac Vasc Anesth; 2007 Dec; 11(4):274-81. PubMed ID: 18270192
[TBL] [Abstract][Full Text] [Related]
15. Near-infrared spectroscopy to monitor cerebral oxygen saturation in single-ventricle physiology.
Ricci M; Lombardi P; Schultz S; Galindo A; Coscarella E; Vasquez A; Rosenkranz E
J Thorac Cardiovasc Surg; 2006 Feb; 131(2):395-402. PubMed ID: 16434270
[TBL] [Abstract][Full Text] [Related]
16. Near-infrared spectroscopy in carotid artery stenting predicts cerebral hyperperfusion syndrome.
Matsumoto S; Nakahara I; Higashi T; Iwamuro Y; Watanabe Y; Takahashi K; Ando M; Takezawa M; Kira JI
Neurology; 2009 Apr; 72(17):1512-8. PubMed ID: 19398706
[TBL] [Abstract][Full Text] [Related]
17. Noninvasive monitoring of human consciousness by near-infrared spectroscopy (NIRS) during high +Gz stress.
Ryoo HC; Hrebien L; Shender BS
Biomed Sci Instrum; 2002; 38():1-7. PubMed ID: 12085583
[TBL] [Abstract][Full Text] [Related]
18. [Assessment of cerebral ischemia by oxygen pulse-based near-infrared optical topography].
Ebihara A; Tanaka Y; Watanabe E; Obata A; Ichikawa N
Brain Nerve; 2008 May; 60(5):547-53. PubMed ID: 18516977
[TBL] [Abstract][Full Text] [Related]
19. Near-infrared spectroscopy in the fetus and neonate.
Wolfberg AJ; du Plessis AJ
Clin Perinatol; 2006 Sep; 33(3):707-28, viii. PubMed ID: 16950321
[TBL] [Abstract][Full Text] [Related]
20. Effect of volume resuscitation on regional perfusion in dehydrated pediatric patients as measured by two-site near-infrared spectroscopy.
Hanson SJ; Berens RJ; Havens PL; Kim MK; Hoffman GM
Pediatr Emerg Care; 2009 Mar; 25(3):150-3. PubMed ID: 19262423
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]