153 related articles for article (PubMed ID: 11451126)
1. Effect of early axial dynamization on tibial bone healing: a study in dogs.
Larsson S; Kim W; Caja VL; Egger EL; Inoue N; Chao EY
Clin Orthop Relat Res; 2001 Jul; (388):240-51. PubMed ID: 11451126
[TBL] [Abstract][Full Text] [Related]
2. Effects of axial dynamization on bone healing.
Egger EL; Gottsauner-Wolf F; Palmer J; Aro HT; Chao EY
J Trauma; 1993 Feb; 34(2):185-92. PubMed ID: 8459454
[TBL] [Abstract][Full Text] [Related]
3. In vivo axial dynamization of canine tibial fractures using the Securos external skeletal fixation system.
Gorman SC; Kraus KH; Keating JH; Tidwell AS; Rand WM; Parkington JD; Boudrieau RJ
Vet Comp Orthop Traumatol; 2005; 18(4):199-207. PubMed ID: 16594387
[TBL] [Abstract][Full Text] [Related]
4. The effects of dynamization and destabilization of the external fixator on fracture healing: a comparative biomechanical study in dogs.
Arazi M; Yalcin H; Tarakcioglu N; Dasci Z; Kutlu A
Orthopedics; 2002 May; 25(5):521-4. PubMed ID: 12046912
[TBL] [Abstract][Full Text] [Related]
5. Load transmission through the callus site with external fixation systems: theoretical and experimental analysis.
Prat J; Juan JA; Vera P; Hoyos JV; Dejoz R; Peris JL; Sánchez-Lacuesta J; Comín M
J Biomech; 1994 Apr; 27(4):469-78. PubMed ID: 8188727
[TBL] [Abstract][Full Text] [Related]
6. Effect of dynamization on gap healing of diaphyseal fractures under external fixation.
Claes LE; Wilke HJ; Augat P; Rübenacker S; Margevicius KJ
Clin Biomech (Bristol, Avon); 1995 Jul; 10(5):227-234. PubMed ID: 11415558
[TBL] [Abstract][Full Text] [Related]
7. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression.
Aro HT; Chao EY
Clin Orthop Relat Res; 1993 Aug; (293):8-17. PubMed ID: 8339513
[TBL] [Abstract][Full Text] [Related]
8. Fracture healing of the sheep tibia treated using a unilateral external fixator. Comparison of static and dynamic fixation.
Hente R; Cordey J; Rahn BA; Maghsudi M; von Gumppenberg S; Perren SM
Injury; 1999; 30 Suppl 1():A44-51. PubMed ID: 10645369
[TBL] [Abstract][Full Text] [Related]
9. Early dynamization by reduced fixation stiffness does not improve fracture healing in a rat femoral osteotomy model.
Claes L; Blakytny R; Göckelmann M; Schoen M; Ignatius A; Willie B
J Orthop Res; 2009 Jan; 27(1):22-7. PubMed ID: 18634011
[TBL] [Abstract][Full Text] [Related]
10. The effects of physiologic dynamic compression on bone healing under external fixation.
Aro HT; Kelly PJ; Lewallen DG; Chao EY
Clin Orthop Relat Res; 1990 Jul; (256):260-73. PubMed ID: 2364613
[TBL] [Abstract][Full Text] [Related]
11. Effects of torsional rigidity on fracture healing: strength and mineralization in rat femora.
Utvåg SE; Rindal DB; Reikerås O
J Orthop Trauma; 1999; 13(3):212-9. PubMed ID: 10206254
[TBL] [Abstract][Full Text] [Related]
12. A study of fracture callus material properties: relationship to the torsional strength of bone.
Markel MD; Wikenheiser MA; Chao EY
J Orthop Res; 1990 Nov; 8(6):843-50. PubMed ID: 2213341
[TBL] [Abstract][Full Text] [Related]
13. Reverse Dynamization Accelerates Bone-Healing in a Large-Animal Osteotomy Model.
Glatt V; Samchukov M; Cherkashin A; Iobst C
J Bone Joint Surg Am; 2021 Feb; 103(3):257-263. PubMed ID: 33315696
[TBL] [Abstract][Full Text] [Related]
14. The Relation between the Dynamization of Hexapod Circular External Fixator and Tibial Mechanical Properties.
Mao Y; Lin Q; Yang Q
Orthop Surg; 2023 Jun; 15(6):1677-1684. PubMed ID: 37154090
[TBL] [Abstract][Full Text] [Related]
15. Interaction between active motion and exogenous transforming growth factor Beta during tibial fracture repair.
Park SH; O'Connor KM; McKellop H
J Orthop Trauma; 2003 Jan; 17(1):2-10. PubMed ID: 12499962
[TBL] [Abstract][Full Text] [Related]
16. Dynamization timing and its effect on bone healing when using the Orthofix Dynamic Axial Fixator.
Foxworthy M; Pringle RM
Injury; 1995 Mar; 26(2):117-9. PubMed ID: 7721463
[TBL] [Abstract][Full Text] [Related]
17. [Dynamization of fracture fixation : Timing and methods].
Claes L
Unfallchirurg; 2018 Jan; 121(1):3-9. PubMed ID: 29318341
[TBL] [Abstract][Full Text] [Related]
18. Comparison of osteotomy healing under external fixation devices with different stiffness characteristics.
Wu JJ; Shyr HS; Chao EY; Kelly PJ
J Bone Joint Surg Am; 1984 Oct; 66(8):1258-64. PubMed ID: 6490701
[TBL] [Abstract][Full Text] [Related]
19. The influence of cyclic compression and distraction on the healing of experimental tibial fractures.
Hente R; Füchtmeier B; Schlegel U; Ernstberger A; Perren SM
J Orthop Res; 2004 Jul; 22(4):709-15. PubMed ID: 15183425
[TBL] [Abstract][Full Text] [Related]
20. Temporal variation in fixation stiffness affects healing by differential cartilage formation in a rat osteotomy model.
Willie BM; Blakytny R; Glöckelmann M; Ignatius A; Claes L
Clin Orthop Relat Res; 2011 Nov; 469(11):3094-101. PubMed ID: 21416204
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]