142 related articles for article (PubMed ID: 11458260)
21. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.
Dailey B; Jordan L; Blind O; Tavernier B
Int J Oral Maxillofac Implants; 2009; 24(2):251-6. PubMed ID: 19492640
[TBL] [Abstract][Full Text] [Related]
22. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
Guda T; Ross TA; Lang LA; Millwater HR
J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
[TBL] [Abstract][Full Text] [Related]
23. Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study.
Schmitt J; Holst S; Eitner S; Schlegel A; Wichmann M; Hamel J
Int J Prosthodont; 2009; 22(2):193-200. PubMed ID: 19418868
[TBL] [Abstract][Full Text] [Related]
24. Implant abutment deformation during prosthetic cylinder screw tightening: an in vitro study.
Neto RT; Moura MS; Souza EA; Rubo JH
Int J Prosthodont; 2009; 22(4):391-5. PubMed ID: 19639078
[TBL] [Abstract][Full Text] [Related]
25. External hexagon and internal hexagon in straight and offset implant placement: strain gauge analysis.
Nishioka RS; de Vasconcellos LG; de Melo Nishioka LN
Implant Dent; 2009 Dec; 18(6):512-20. PubMed ID: 20009605
[TBL] [Abstract][Full Text] [Related]
26. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.
Quek HC; Tan KB; Nicholls JI
Int J Oral Maxillofac Implants; 2008; 23(2):253-62. PubMed ID: 18548921
[TBL] [Abstract][Full Text] [Related]
27. Preload loss in gold prosthesis-retaining screws as a function of time.
Cantwell A; Hobkirk JA
Int J Oral Maxillofac Implants; 2004; 19(1):124-32. PubMed ID: 14982365
[TBL] [Abstract][Full Text] [Related]
28. Removal torque of immediately loaded transitional endosseous implants in human subjects.
Simon H; Caputo AA
Int J Oral Maxillofac Implants; 2002; 17(6):839-45. PubMed ID: 12507244
[TBL] [Abstract][Full Text] [Related]
29. Accuracy of implant impression techniques.
Assif D; Marshak B; Schmidt A
Int J Oral Maxillofac Implants; 1996; 11(2):216-22. PubMed ID: 8666454
[TBL] [Abstract][Full Text] [Related]
30. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments.
Naconecy MM; Teixeira ER; Shinkai RS; Frasca LC; Cervieri A
Int J Oral Maxillofac Implants; 2004; 19(2):192-8. PubMed ID: 15101589
[TBL] [Abstract][Full Text] [Related]
31. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
Xia D; Lin H; Yuan S; Bai W; Zheng G
Biomed Mater Eng; 2014; 24(6):2143-9. PubMed ID: 25226912
[TBL] [Abstract][Full Text] [Related]
32. The implant-supported single-tooth restoration. Preoperative evaluation and clinical procedure.
Boudrias P
Dent Clin North Am; 1993 Jul; 37(3):497-511. PubMed ID: 8349001
[TBL] [Abstract][Full Text] [Related]
33. Resistance of ITI implant connectors to multivectorial fatigue load application.
Wiskott HW; Pavone AF; Scherrer SS; Renevey RR; Belser UC
Int J Prosthodont; 2004; 17(6):672-9. PubMed ID: 15686095
[TBL] [Abstract][Full Text] [Related]
34. Accuracy of impression and pouring techniques for an implant-supported prosthesis.
Del'Acqua MA; Arioli-Filho JN; Compagnoni MA; Mollo Fde A
Int J Oral Maxillofac Implants; 2008; 23(2):226-36. PubMed ID: 18548918
[TBL] [Abstract][Full Text] [Related]
35. Removal torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area.
Squier RS; Psoter WJ; Taylor TD
Int J Oral Maxillofac Implants; 2002; 17(1):24-7. PubMed ID: 11858571
[TBL] [Abstract][Full Text] [Related]
36. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
[TBL] [Abstract][Full Text] [Related]
37. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection.
Wenz HJ; Hertrampf K
Int J Oral Maxillofac Implants; 2008; 23(1):39-47. PubMed ID: 18416411
[TBL] [Abstract][Full Text] [Related]
38. Loss of preload in screwed implant joints as a function of time and tightening/untightening sequences.
Bernardes SR; da Gloria Chiarello de Mattos M; Hobkirk J; Ribeiro RF
Int J Oral Maxillofac Implants; 2014; 29(1):89-96. PubMed ID: 24451858
[TBL] [Abstract][Full Text] [Related]
39. Load fatigue performance of implant-ceramic abutment combinations.
Nguyen HQ; Tan KB; Nicholls JI
Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403
[TBL] [Abstract][Full Text] [Related]
40. Accuracy of electronic implant torque controllers following time in clinical service.
Mitrani R; Nicholls JI; Phillips KM; Ma T
Int J Oral Maxillofac Implants; 2001; 16(3):394-9. PubMed ID: 11432659
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]