BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 11463657)

  • 21. The effect of asymmetric surface potentials on the intramembrane electric field measured with voltage-sensitive dyes.
    Xu C; Loew LM
    Biophys J; 2003 Apr; 84(4):2768-80. PubMed ID: 12668484
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measuring the induced membrane voltage with Di-8-ANEPPS.
    Pucihar G; Kotnik T; Miklavcic D
    J Vis Exp; 2009 Nov; (33):. PubMed ID: 19927116
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Charge-shift probes of membrane potential. Characterization of aminostyrylpyridinium dyes on the squid giant axon.
    Loew LM; Cohen LB; Salzberg BM; Obaid AL; Bezanilla F
    Biophys J; 1985 Jan; 47(1):71-7. PubMed ID: 3978192
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Isosbestic Point in Optical Mapping; Theoretical and Experimental Determination With Di-4-ANBDQPQ Transmembrane Voltage Sensitive Dye.
    Uzelac I; Crowley CJ; Fenton FH
    Comput Cardiol (2010); 2019 Sep; 46():. PubMed ID: 34722782
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Measurement of membrane potential and intracellular Ca(2+) of arteriolar endothelium and smooth muscle in vivo.
    Chen Y; Rivers RJ
    Microvasc Res; 2001 Jul; 62(1):55-62. PubMed ID: 11421660
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Potential-modulated fluorescence spectroscopy of the membrane potential-sensitive dye di-4-ANEPPS at the 1,2-dichloroethane/water interface.
    Osakai T; Sawada J; Nagatani H
    Anal Bioanal Chem; 2009 Oct; 395(4):1055-61. PubMed ID: 19588129
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Action spectra of electrochromic voltage-sensitive dyes in an intact excitable tissue.
    Foley J; Muschol M
    J Biomed Opt; 2008; 13(6):064015. PubMed ID: 19123661
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Spectral properties and orientation of voltage-sensitive dyes in lipid membranes.
    Matson M; Carlsson N; Beke-Somfai T; Nordén B
    Langmuir; 2012 Jul; 28(29):10808-17. PubMed ID: 22738247
    [TBL] [Abstract][Full Text] [Related]  

  • 29. New near-infrared optical probes of cardiac electrical activity.
    Matiukas A; Mitrea BG; Pertsov AM; Wuskell JP; Wei MD; Watras J; Millard AC; Loew LM
    Am J Physiol Heart Circ Physiol; 2006 Jun; 290(6):H2633-43. PubMed ID: 16399869
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An evaluation of in vivo voltage-sensitive dyes: pharmacological side effects and signal-to-noise ratios after effective removal of brain-pulsation artifacts.
    Grandy TH; Greenfield SA; Devonshire IM
    J Neurophysiol; 2012 Dec; 108(11):2931-45. PubMed ID: 22972958
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Charge-shift probes of membrane potential: a probable electrochromic mechanism for p-aminostyrylpyridinium probes on a hemispherical lipid bilayer.
    Loew LM; Simpson LL
    Biophys J; 1981 Jun; 34(3):353-65. PubMed ID: 7248466
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biolistic delivery of voltage-sensitive dyes for fast recording of membrane potential changes in individual neurons in rat brain slices.
    Aseyev N; Roshchin M; Ierusalimsky VN; Balaban PM; Nikitin ES
    J Neurosci Methods; 2013 Jan; 212(1):17-27. PubMed ID: 22983172
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Voltage-sensitive fluorescence of amphiphilic hemicyanine dyes in a black lipid membrane of glycerol monooleate.
    Fromherz P; Schenk O
    Biochim Biophys Acta; 1994 May; 1191(2):299-308. PubMed ID: 8172915
    [TBL] [Abstract][Full Text] [Related]  

  • 34. High sensitivity of Stark-shift voltage-sensing dyes by one- or two-photon excitation near the red spectral edge.
    Kuhn B; Fromherz P; Denk W
    Biophys J; 2004 Jul; 87(1):631-9. PubMed ID: 15240496
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A naphthyl analog of the aminostyryl pyridinium class of potentiometric membrane dyes shows consistent sensitivity in a variety of tissue, cell, and model membrane preparations.
    Loew LM; Cohen LB; Dix J; Fluhler EN; Montana V; Salama G; Wu JY
    J Membr Biol; 1992 Oct; 130(1):1-10. PubMed ID: 1469705
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Intravital multiphoton photoconversion with a cell membrane dye.
    Turcotte R; Wu JW; Lin CP
    J Biophotonics; 2017 Feb; 10(2):206-210. PubMed ID: 27433967
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Spectra, membrane binding, and potentiometric responses of new charge shift probes.
    Fluhler E; Burnham VG; Loew LM
    Biochemistry; 1985 Oct; 24(21):5749-55. PubMed ID: 4084490
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Errors caused by combination of Di-4 ANEPPS and Fluo3/4 for simultaneous measurements of transmembrane potentials and intracellular calcium.
    Johnson PL; Smith W; Baynham TC; Knisley SB
    Ann Biomed Eng; 1999; 27(4):563-71. PubMed ID: 10468240
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effects of nitric oxide donors, S-nitroso-L-cysteine and sodium nitroprusside, on the whole-cell and single channel currents in single myocytes of the guinea-pig proximal colon.
    Lang RJ; Watson MJ
    Br J Pharmacol; 1998 Feb; 123(3):505-17. PubMed ID: 9504392
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Voltage sensitivity of the fluorescent probe RH421 in a model membrane system.
    Clarke RJ; Zouni A; Holzwarth JF
    Biophys J; 1995 Apr; 68(4):1406-15. PubMed ID: 7787026
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.