BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 11465226)

  • 1. Hemodynamic performance of stented and stentless aortic bioprostheses.
    Milano AD; Blanzola C; Mecozzi G; D'Alfonso A; De Carlo M; Nardi C; Bortolotti U
    Ann Thorac Surg; 2001 Jul; 72(1):33-8. PubMed ID: 11465226
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.
    Bleiziffer S; Eichinger WB; Wagner I; Guenzinger R; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2005 Nov; 14(6):814-21; discussion 821. PubMed ID: 16359064
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study.
    Borger MA; Carson SM; Ivanov J; Rao V; Scully HE; Feindel CM; David TE
    Ann Thorac Surg; 2005 Dec; 80(6):2180-5. PubMed ID: 16305867
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis.
    Bakhtiary F; Schiemann M; Dzemali O; Wittlinger T; Doss M; Ackermann H; Moritz A; Kleine P
    J Thorac Cardiovasc Surg; 2006 Apr; 131(4):883-8. PubMed ID: 16580448
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.
    Tasca G; Stefano A; Giannico F; Lobiati E; Riva B; Galanti A; Triggiani M; Gamba A
    J Heart Valve Dis; 2014 Sep; 23(5):633-41. PubMed ID: 25799714
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.
    Doss M; Martens S; Wood JP; Aybek T; Kleine P; Wimmer Greinecker G; Moritz A
    Eur J Cardiothorac Surg; 2003 Mar; 23(3):299-304. PubMed ID: 12614797
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Early clinical and hemodynamic outcomes after stented and stentless aortic valve replacement: results from a randomized controlled trial.
    Ali A; Halstead JC; Cafferty F; Sharples L; Rose F; Lee E; Rusk R; Dunning J; Argano V; Tsui S
    Ann Thorac Surg; 2007 Jun; 83(6):2162-8. PubMed ID: 17532416
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Are stentless valves superior to modern stented valves? A prospective randomized trial.
    Ali A; Halstead JC; Cafferty F; Sharples L; Rose F; Coulden R; Lee E; Dunning J; Argano V; Tsui S
    Circulation; 2006 Jul; 114(1 Suppl):I535-40. PubMed ID: 16820633
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stented versus stentless bioprostheses in aortic valve stenosis: effect on left ventricular remodelling.
    Tsialtas D; Bolognesi R; Beghi C; Albertini D; Bolognesi MG; Manca C; Gherli T
    Heart Surg Forum; 2007; 10(3):E205-10. PubMed ID: 17389213
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve: early clinical and hemodynamic results of a randomized comparison in 160 patients.
    Chambers JB; Rimington HM; Hodson F; Rajani R; Blauth CI
    J Thorac Cardiovasc Surg; 2006 Apr; 131(4):878-2. PubMed ID: 16580447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective randomized evaluation of stentless vs. stented aortic biologic prosthetic valves in the elderly at five years.
    Risteski PS; Martens S; Rouhollahpour A; Wimmer-Greinecker G; Moritz A; Doss M
    Interact Cardiovasc Thorac Surg; 2009 Apr; 8(4):449-53. PubMed ID: 19126556
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stentless bioprostheses for the small aortic root.
    Walther T; Falk V; Diegeler A; Autschbach R; Gummert J; Baryalei M; Mohr FW
    J Heart Valve Dis; 1996 Nov; 5 Suppl 3():S302-7. PubMed ID: 8953458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus.
    Botzenhardt F; Eichinger WB; Bleiziffer S; Guenzinger R; Wagner IM; Bauernschmitt R; Lange R
    J Am Coll Cardiol; 2005 Jun; 45(12):2054-60. PubMed ID: 15963409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effective orifice area/patient aortic annulus area ratio: a better way to compare different bioprostheses? A prospective randomized comparison of the Mosaic and Perimount bioprostheses in the aortic position.
    Eichinger WB; Botzenhardt F; Guenzinger R; Bleiziffer S; Keithahn A; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2004 May; 13(3):382-8; discussion 388-9. PubMed ID: 15222284
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.
    Tavakoli R; Auf der Maur C; Mueller X; Schläpfer R; Jamshidi P; Daubeuf F; Frossard N
    J Cardiothorac Surg; 2015 Feb; 10():15. PubMed ID: 25643748
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.
    Tavakoli R; Danial P; Oudjana AH; Jamshidi P; Gassmann M; Leprince P; Lebreton G
    Gen Thorac Cardiovasc Surg; 2018 May; 66(5):247-256. PubMed ID: 29322433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stentless Pericarbon Freedom Versus Stented Perimount Aortic Bioprosthesis: Propensity-Matched Long-Term Follow-Up.
    Stefanelli G; Pirro F; Smorto V; Bellisario A; Chiurlia E; Weltert L
    Innovations (Phila); 2020; 15(5):440-448. PubMed ID: 32628077
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stentless or stented aortic valve implants in elderly patients?
    Van Nooten G; Caes F; François K; Van Belleghem Y; Taeymans Y
    Eur J Cardiothorac Surg; 1999 Jan; 15(1):31-6. PubMed ID: 10077370
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stented bioprosthetic valve hemodynamics: is the supra-annular implant better than the intra-annular?
    Badano LP; Pavoni D; Musumeci S; Frassani R; Gianfagna P; Baldassi M; Tursi V; Mazzaro E; Zakja E; Fioretti PM; Livi U
    J Heart Valve Dis; 2006 Mar; 15(2):238-46. PubMed ID: 16607907
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.