These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements. Stout PJ; Racchini JR; Hilgers ME Diabetes Technol Ther; 2004 Oct; 6(5):635-44. PubMed ID: 15628817 [TBL] [Abstract][Full Text] [Related]
4. Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset. Rebrin K; Sheppard NF; Steil GM J Diabetes Sci Technol; 2010 Sep; 4(5):1087-98. PubMed ID: 20920428 [TBL] [Abstract][Full Text] [Related]
5. Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: implications for glucose monitoring. Smith A; Yang D; Delcher H; Eppstein J; Williams D; Wilkes S Diabetes Technol Ther; 1999; 1(1):21-7. PubMed ID: 11475300 [TBL] [Abstract][Full Text] [Related]
6. Assessment of trueness of a glucose monitor using interstitial fluid and whole blood as specimen matrix. Vesper HW; Wang PM; Archibold E; Prausnitz MR; Myers GL Diabetes Technol Ther; 2006 Feb; 8(1):76-80. PubMed ID: 16472053 [TBL] [Abstract][Full Text] [Related]
7. Modeling Plasma-to-Interstitium Glucose Kinetics from Multitracer Plasma and Microdialysis Data. Schiavon M; Dalla Man C; Dube S; Slama M; Kudva YC; Peyser T; Basu A; Basu R; Cobelli C Diabetes Technol Ther; 2015 Nov; 17(11):825-31. PubMed ID: 26313215 [TBL] [Abstract][Full Text] [Related]
8. Dermal interstitial glucose as an indicator of ambient glycemia. Service FJ; O'Brien PC; Wise SD; Ness S; LeBlanc SM Diabetes Care; 1997 Sep; 20(9):1426-9. PubMed ID: 9283791 [TBL] [Abstract][Full Text] [Related]
9. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Rebrin K; Steil GM; van Antwerp WP; Mastrototaro JJ Am J Physiol; 1999 Sep; 277(3):E561-71. PubMed ID: 10484370 [TBL] [Abstract][Full Text] [Related]
10. Analytical characterization of electrochemical biosensor test strips for measurement of glucose in low-volume interstitial fluid samples. Collison ME; Stout PJ; Glushko TS; Pokela KN; Mullins-Hirte DJ; Racchini JR; Walter MA; Mecca SP; Rundquist J; Allen JJ; Hilgers ME; Hoegh TB Clin Chem; 1999 Sep; 45(9):1665-73. PubMed ID: 10471681 [TBL] [Abstract][Full Text] [Related]
11. Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles. Wang PM; Cornwell M; Prausnitz MR Diabetes Technol Ther; 2005 Feb; 7(1):131-41. PubMed ID: 15738711 [TBL] [Abstract][Full Text] [Related]
12. Putative delays in interstitial fluid (ISF) glucose kinetics can be attributed to the glucose sensing systems used to measure them rather than the delay in ISF glucose itself. Voskanyan G; Barry Keenan D; Mastrototaro JJ; Steil GM J Diabetes Sci Technol; 2007 Sep; 1(5):639-44. PubMed ID: 19885132 [TBL] [Abstract][Full Text] [Related]
13. Reconstructing by deconvolution plasma glucose from continuous glucose monitoring sensor data. Facchinetti A; Sparacino G; Zanderigo F; Cobelli C Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():55-8. PubMed ID: 17946377 [TBL] [Abstract][Full Text] [Related]
14. Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling. Sato T; Okada S; Hagino K; Asakura Y; Kikkawa Y; Kojima J; Watanabe T; Maekawa Y; Isobe K; Koike R; Nakajima H; Asano K Diabetes Technol Ther; 2011 Dec; 13(12):1194-200. PubMed ID: 21770766 [TBL] [Abstract][Full Text] [Related]
15. Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study. Cobelli C; Schiavon M; Dalla Man C; Basu A; Basu R Diabetes Technol Ther; 2016 Aug; 18(8):505-11. PubMed ID: 27253751 [TBL] [Abstract][Full Text] [Related]
16. Noninvasive glucose measurement by monitoring of scattering coefficient during oral glucose tolerance tests. Non-Invasive Task Force. Heinemann L; Krämer U; Klötzer HM; Hein M; Volz D; Hermann M; Heise T; Rave K; Diabetes Technol Ther; 2000; 2(2):211-20. PubMed ID: 11469261 [TBL] [Abstract][Full Text] [Related]
17. Discrepancies Between Blood Glucose and Interstitial Glucose-Technological Artifacts or Physiology: Implications for Selection of the Appropriate Therapeutic Target. Siegmund T; Heinemann L; Kolassa R; Thomas A J Diabetes Sci Technol; 2017 Jul; 11(4):766-772. PubMed ID: 28322063 [TBL] [Abstract][Full Text] [Related]
19. Extracellular glucose distribution is not altered by insulin: analysis of plasma and interstitial L-glucose kinetics. Steil GM; Richey J; Kim JK; Wi JK; Rebrin K; Bergman RN; Youn JH Am J Physiol; 1996 Nov; 271(5 Pt 1):E855-64. PubMed ID: 8944672 [TBL] [Abstract][Full Text] [Related]
20. Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid. Bantle JP; Thomas W J Lab Clin Med; 1997 Oct; 130(4):436-41. PubMed ID: 9358083 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]