These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
191 related articles for article (PubMed ID: 11467529)
1. A Schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion. Shamsipur M; Yousefi M; Hosseini M; Ganjali MR; Sharghi H; Naeimi H Anal Chem; 2001 Jul; 73(13):2869-74. PubMed ID: 11467529 [TBL] [Abstract][Full Text] [Related]
2. PVC membrane and coated graphite potentiometric sensors based on Et4todit for selective determination of samarium(III). Shamsipur M; Hosseini M; Alizadeh K; Talebpour Z; Mousavi MF; Ganjali MR; Arca M; Lippolis V Anal Chem; 2003 Nov; 75(21):5680-6. PubMed ID: 14588005 [TBL] [Abstract][Full Text] [Related]
3. A novel flow injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion. Shamsipur M; Mizani F; Mousavi MF; Alizadeh N; Alizadeh K; Eshghi H; Karami H Anal Chim Acta; 2007 Apr; 589(1):22-32. PubMed ID: 17397648 [TBL] [Abstract][Full Text] [Related]
5. A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensors for copper(II) ion. Shamsipur M; Avanes A; Javanbakht M; Ganjali MR; Sharghi H Anal Sci; 2002 Aug; 18(8):875-9. PubMed ID: 12200832 [TBL] [Abstract][Full Text] [Related]
6. Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore. Mahajan RK; Kamal A; Kumar N; Bhalla V; Kumar M Environ Sci Pollut Res Int; 2013 May; 20(5):3086-97. PubMed ID: 23054787 [TBL] [Abstract][Full Text] [Related]
7. Nano-level monitoring of Er(III) by fabrication of coated graphite electrode based on newly synthesized Schiff base as neutral carrier. Bandi KR; Upadhyay A; Singh AK; Jain AK Mater Sci Eng C Mater Biol Appl; 2016 May; 62():9-17. PubMed ID: 26952392 [TBL] [Abstract][Full Text] [Related]
8. New selenite ion-selective electrodes based on 5,10,15,20-tetrakis-(4-methoxyphenyl)-21H,23H-porphyrin-Co(II). Ibrahim H; Issa YM; Shehab OR J Hazard Mater; 2010 Sep; 181(1-3):857-67. PubMed ID: 20561747 [TBL] [Abstract][Full Text] [Related]
9. Uranyl-selective PVC membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides. Shamsipur M; Soleymanpour A; Akhond M; Sharghi H; Massah AR Talanta; 2002 Aug; 58(2):237-46. PubMed ID: 18968747 [TBL] [Abstract][Full Text] [Related]
10. Highly selective potentiometric and colorimetric determinations of cobalt (II) ion using thiazole based ligands. Singhal D; Singh AK; Upadhyay A Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():216-24. PubMed ID: 25491823 [TBL] [Abstract][Full Text] [Related]
11. Highly selective PVC-membrane electrodes based on Co(II)-Salen for determination of nitrite ion. Ganjali MR; Rezapour M; Pourjavid MR; Salavati-Niasari M Anal Sci; 2003 Aug; 19(8):1127-31. PubMed ID: 12945664 [TBL] [Abstract][Full Text] [Related]
12. Nano-level monitoring of Yb(III) by fabrication of coated graphite electrode based on newly synthesized hexaaza macrocyclic ligand. Singh AK; Singh P Anal Chim Acta; 2009 Jun; 643(1-2):74-82. PubMed ID: 19446066 [TBL] [Abstract][Full Text] [Related]
13. Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle. Singh AK; Singh P Anal Chim Acta; 2010 Aug; 675(2):170-80. PubMed ID: 20800729 [TBL] [Abstract][Full Text] [Related]
14. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands. Singh AK; Singh P; Banerjee S; Mehtab S Anal Chim Acta; 2009 Feb; 633(1):109-18. PubMed ID: 19110124 [TBL] [Abstract][Full Text] [Related]
15. Determination of thiocyanate ions at nanolevel in real samples using coated graphite electrode based on synthesised macrocyclic Zn(II) complex. Singh P; Singh AK Anal Bioanal Chem; 2011 Jun; 400(7):2261-9. PubMed ID: 21475945 [TBL] [Abstract][Full Text] [Related]
16. Electroanalytical studies on Cu (II) ion-selective sensor of coated pyrolytic graphite electrodes based on N2S2O2 and N2S2O3 heterocyclic benzothiazol ligands. Singh AK; Sahani MK; Bandi KR; Jain AK Mater Sci Eng C Mater Biol Appl; 2014 Aug; 41():206-16. PubMed ID: 24907753 [TBL] [Abstract][Full Text] [Related]
17. Fabrication of novel coated pyrolytic graphite electrodes for the selective nano-level monitoring of Cd²⁺ ions in biological and environmental samples using polymeric membrane of newly synthesized macrocycle. Sahani MK; Singh AK; Jain AK; Upadhyay A; Kumar A; Singh UP; Narang S Anal Chim Acta; 2015 Feb; 860():51-60. PubMed ID: 25682247 [TBL] [Abstract][Full Text] [Related]
18. Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex. Ganjali MR; Norouzi P; Gol-Mohammadi M; Mizani F; Poursaberi T; Salavati-Niasari M; Shamsipur M; Hosseini M; Javanbakht M Ann Chim; 2003; 93(7-8):679-90. PubMed ID: 12940601 [TBL] [Abstract][Full Text] [Related]
19. Electroanalytical and naked eye determination of Cu(2+) ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases. Bandi KR; Singh AK; Upadhyay A Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():149-57. PubMed ID: 24268244 [TBL] [Abstract][Full Text] [Related]
20. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode. Singh AK; Singh P; Bhattacharjee G Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]