BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 11469613)

  • 1. A miniaturized self-contained single-use disposable quantitatitve test for hemoglobin A1c in blood at the point of care.
    Stivers CR; Baddam SR; Clark AL; Ammirati EB; Irvin BR; Blatt JM
    Diabetes Technol Ther; 2000; 2(4):517-26. PubMed ID: 11469613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Glycosal: the first rapid, point-of-care test for the determination of hemoglobin A1c in patients with diabetes.
    Stevenson T
    Diabetes Technol Ther; 1999; 1(4):425-31. PubMed ID: 11474827
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective evaluation of accuracy, precision, and reproducibility of an at-home hemoglobin A1c sampling kit.
    Parkes J; Ray R; Kerestan S; Davis H; Ginsberg B
    Diabetes Technol Ther; 1999; 1(4):411-9. PubMed ID: 11474825
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A microfluidic device integrating dual CMOS polysilicon nanowire sensors for on-chip whole blood processing and simultaneous detection of multiple analytes.
    Kuan DH; Wang IS; Lin JR; Yang CH; Huang CH; Lin YH; Lin CT; Huang NT
    Lab Chip; 2016 Aug; 16(16):3105-13. PubMed ID: 27314254
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of point-of-care and over-the-counter testing methods for hemoglobin A1c: how good do they need to be?
    Little RR
    J Diabetes Sci Technol; 2010 Nov; 4(6):1504-6. PubMed ID: 21129347
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Rapid Test Strip for Diagnosing Glycosylated Hemoglobin (HbA1c) Based on Fluorescent Affinity Immunochromatography.
    Ang C; Lou D; Hu L; Chen W; Zhu Y; Guo Z; Gu N; Zhang Y
    Anal Sci; 2018 Oct; 34(10):1117-1123. PubMed ID: 29863029
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy and Precision of a Point-of-Care HbA1c Test.
    Arnold WD; Kupfer K; Little RR; Amar M; Horowitz B; Godbole N; Hvidsten Swensen M; Li Y; San George RC
    J Diabetes Sci Technol; 2020 Sep; 14(5):883-889. PubMed ID: 30854894
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Verification of a novel point-of-care HbA
    Wang Y; Peng W; Tang J; Dong L; Gu C; Zhang X; Zhou J; Jia W
    Biochem Med (Zagreb); 2018 Jun; 28(2):020705. PubMed ID: 29666558
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test.
    Arnold WD; Kupfer K; Hvidsten Swensen M; Fortner KS; Bays HE; Davis M; Klaff LJ; San George RC
    J Diabetes Sci Technol; 2020 Sep; 14(5):890-895. PubMed ID: 30841743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of Two Diabetes Point-of-care Analyzers Measuring Hemoglobin A1c in the Peruvian Amazon.
    Saxton AT; Miranda JJ; Ortiz EJ; Pan W
    Ann Glob Health; 2018 Nov; 84(4):618-624. PubMed ID: 30779508
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A1c Gear: Laboratory quality HbA1c measurement at the point of care.
    Ejilemele A; Unabia J; Ju H; Petersen JR
    Clin Chim Acta; 2015 May; 445():139-42. PubMed ID: 25801216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nurse-based evaluation of point-of-care assays for glycated haemoglobin.
    St John A; Davis TM; Goodall I; Townsend MA; Price CP
    Clin Chim Acta; 2006 Mar; 365(1-2):257-63. PubMed ID: 16202401
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a new hemoglobin A1c analyzer for point-of-care testing.
    Zhou R; Wang W; Song ZX; Tong Q; Wang QT
    J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28220976
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A lateral flow immunosensor for direct, sensitive, and highly selective detection of hemoglobin A1c in whole blood.
    Ang SH; Thevarajah TM; Woi PM; Alias YB; Khor SM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Mar; 1015-1016():157-165. PubMed ID: 26927875
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy and clinical utility of a point-of-care HbA1c testing device.
    Knaebel J; Irvin BR; Xie CZ
    Postgrad Med; 2013 May; 125(3):91-8. PubMed ID: 23748510
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implications of point-of-care testing for hemoglobin A1c.
    Porter KH; Myers GL
    Diabetes Technol Ther; 2000; 2(4):527-8. PubMed ID: 11469614
    [No Abstract]   [Full Text] [Related]  

  • 17. Accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device.
    Wood JR; Kaminski BM; Kollman C; Beck RW; Hall CA; Yun JP; Cengiz E; Haller MJ; Hassan K; Klingensmith GJ; Tamborlane WV
    J Diabetes Sci Technol; 2012 Mar; 6(2):380-6. PubMed ID: 22538150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Haemoglobin A1c: evaluation of three point of care analysers for use in a paediatric diabetes clinic.
    Greaves RF; Northfield JA; Cameron FJ
    Ann Clin Biochem; 2005 Mar; 42(Pt 2):124-9. PubMed ID: 15829121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiple chemiluminescence immunoassay detection of the concentration ratio of glycosylated hemoglobin A1c to total hemoglobin in whole blood samples.
    Zhao H; Qiu X; Su E; Huang L; Zai Y; Liu Y; Chen H; Wang Z; Chen Z; Li S; Jin L; Deng Y; He N
    Anal Chim Acta; 2022 Feb; 1192():339379. PubMed ID: 35057955
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of an over-the-counter glycated hemoglobin (A1C) test kit.
    Chang A; Frank J; Knaebel J; Fullam J; Pardo S; Simmons DA
    J Diabetes Sci Technol; 2010 Nov; 4(6):1495-503. PubMed ID: 21129346
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.