These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 11474937)

  • 21. Microdosimetric calculation of absorption fraction and the resulting dose conversion factor for radon progeny.
    Nikezic D; Yu KN
    Radiat Environ Biophys; 2001 Sep; 40(3):207-11. PubMed ID: 11783849
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The compact disk as radon detector--a laboratory study of the method.
    Pressyanov D; Buysse J; Poffijn A; Meesen G; Van Deynse A
    Health Phys; 2003 May; 84(5):642-51. PubMed ID: 12747485
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Study on radon and radon progeny in some living rooms.
    Mohamed A
    Radiat Prot Dosimetry; 2005; 117(4):402-7. PubMed ID: 15998645
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Measurement of tracheobronchial dose from simultaneous exposure to environmental radon and thoron progeny.
    Yu KN; Guan ZJ; Young EC; Stokes MJ
    Health Phys; 1998 Aug; 75(2):153-8. PubMed ID: 9685068
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Uncertainty analysis of the weighted equivalent lung dose per unit exposure to radon progeny in the home.
    Marsh JW; Birchall A; Butterweck G; Dorrian MD; Huet C; Ortega X; Reineking A; Tymen G; Schuler Ch; Vargas A; Vezzu G; Wendt J
    Radiat Prot Dosimetry; 2002; 102(3):229-48. PubMed ID: 12430962
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Calculation of dose conversion factors for thoron decay products.
    Ishikawa T; Tokonami S; Nemeth C
    J Radiol Prot; 2007 Dec; 27(4):447-56. PubMed ID: 18268375
    [TBL] [Abstract][Full Text] [Related]  

  • 27. ASSESSMENT OF INHALATION DOSE FROM THE INDOOR 222Rn AND 220Rn USING RAD7 AND PINHOLE CUP DOSEMETERS.
    Mehra R; Jakhu R; Bangotra P; Kaur K; Mittal HM
    Radiat Prot Dosimetry; 2016 Oct; 171(2):208-211. PubMed ID: 27036531
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Doses in human organs due to alpha, beta and gamma radiations emitted by thoron progeny in the lung.
    Nikezic D; Markovic VM; Krstic D; Yu PK
    Radiat Prot Dosimetry; 2010 Oct; 141(4):428-31. PubMed ID: 20833674
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of radon lung dosimetry models for the estimation of dose uncertainties.
    Winkler-Heil R; Hofmann W; Marsh J; Birchall A
    Radiat Prot Dosimetry; 2007; 127(1-4):27-30. PubMed ID: 17623685
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Internal microdosimetry of inhaled radon progeny in bronchial airways: advantages and limitations.
    Hofmann W; Fakir H; Pihet P
    Radiat Prot Dosimetry; 2007; 127(1-4):40-5. PubMed ID: 17827134
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of inhomogeneous activity distributions and airway geometry on cellular doses in radon lung dosimetry.
    Szoke I; Balásházy I; Farkas A; Hofmann W
    Radiat Prot Dosimetry; 2007; 127(1-4):68-72. PubMed ID: 17561519
    [TBL] [Abstract][Full Text] [Related]  

  • 32. New calculations for internal dosimetry of beta-emitting radiopharmaceuticals.
    Zankl M; Petoussi-Henss N; Janzen T; Uusijärvi H; Schlattl H; Li WB; Giussani A; Hoeschen C
    Radiat Prot Dosimetry; 2010; 139(1-3):245-9. PubMed ID: 20167794
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Modelling the effect of non-uniform radon progeny activities on transformation frequencies in human bronchial airways.
    Fakir H; Hofmann W; Aubineau-Laniece I
    Radiat Prot Dosimetry; 2006; 121(3):221-35. PubMed ID: 16682395
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dosimetric assessment of radon in a vegetable system.
    Tavera L; Balcázar M; Villalobos-Pietrini R; Flores-Márquez AR; Meneses PM
    Radiat Environ Biophys; 2002 Dec; 41(4):289-93. PubMed ID: 12541075
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effects of mucus thickness and goblet cell hyperplasia on microdosimetric quantities characterizing the bronchial epithelium upon radon exposure.
    Madas BG; Drozsdik EJ
    Int J Radiat Biol; 2018 Nov; 94(11):967-974. PubMed ID: 30265181
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A review of lung-to-blood absorption rates for radon progeny.
    Marsh JW; Bailey MR
    Radiat Prot Dosimetry; 2013 Dec; 157(4):499-514. PubMed ID: 23887272
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cellular dosimetry: absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments.
    Goddu SM; Howell RW; Rao DV
    J Nucl Med; 1994 Feb; 35(2):303-16. PubMed ID: 8295004
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Calculating the calibration coefficient for radon measurements with the bare LR 115-II track detector.
    Nikezić D; Marković P; Uzarov DB
    Health Phys; 1992 Mar; 62(3):239-44. PubMed ID: 1735644
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Levels of nanosize radon decay products in indoor air: a comparison for different environments.
    Vaupotic J
    Coll Antropol; 2008 Oct; 32 Suppl 2():99-104. PubMed ID: 19140272
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Monte Carlo code for microdosimetry of inhaled alpha emitters.
    Aubineau-Laniece I; Pihet P; Winkler R; Hofmann W; Charlton DE
    Radiat Prot Dosimetry; 2002; 99(1-4):463-8. PubMed ID: 12194354
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.