These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 11487239)

  • 1. A laryngoscope designed for intubation of the rat.
    Linden RD; Shields CB; Zhang YP; Edmonds HL; Hunt MA
    Contemp Top Lab Anim Sci; 2000 Mar; 39(2):40-2. PubMed ID: 11487239
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Using a 0.035-in. straight-tip wire and a small infant laryngoscope for safe and easy endotracheal intubations in rats for cardiovascular research.
    Samsamshariat SA; Movahed MR
    Cardiovasc Revasc Med; 2005; 6(4):160-2. PubMed ID: 16326377
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design for a three-dimensional printed laryngoscope blade for the intubation of rats.
    Vongerichten A; Aristovich K; dos Santos GS; McEvoy AW; Holder DS
    Lab Anim (NY); 2014 Apr; 43(4):140-2. PubMed ID: 24651789
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A simple fibreoptic assisted laryngoscope for paediatric difficult intubation: a manikin study.
    Komiya K; Inagawa G; Nakamura K; Kikuchi T; Fujimoto J; Sugawara Y; Goto T
    Anaesthesia; 2009 Apr; 64(4):425-9. PubMed ID: 19317709
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simple, inexpensive, and effective light- carrying laryngoscopic blade for orotracheal intubation of rats.
    Molthen RC
    J Am Assoc Lab Anim Sci; 2006 Jan; 45(1):88-93. PubMed ID: 16539342
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of the flexible fiberoptic laryngoscope.
    Dierdorf SF
    Mt Sinai J Med; 1995 Jan; 62(1):21-6. PubMed ID: 7739580
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Parker Flex-Tip tracheal tube makes endotracheal intubation with the Bullard laryngoscope easier and faster.
    Suzuki A; Tampo A; Abe N; Otomo S; Minami S; Henderson JJ; Iwasaki H
    Eur J Anaesthesiol; 2008 Jan; 25(1):43-7. PubMed ID: 17666155
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparison of performance of endotracheal intubation by senior residents in anesthesiology using Airway Scope VS Macintosh laryngoscope].
    Hakozaki T; Hirabayashi Y; Seo N
    Masui; 2009 Jan; 58(1):100-2. PubMed ID: 19175024
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A new method for endotracheal intubation with the Bullard laryngoscope].
    Miyazawa N; Shigematsu T; Kaneko S; Tabuchi H; Yorozu T; Saito N; Tashiro M
    Masui; 1992 Feb; 41(2):263-9. PubMed ID: 1552667
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison between the Bonfils Intubation Fiberscope and McCoy laryngoscope for tracheal intubation in patients with a simulated difficult airway.
    Abdullah HR; Li-Ming T; Marriott A; Wong TG
    Anesth Analg; 2013 Nov; 117(5):1217-20. PubMed ID: 24029854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Bullard laryngoscope. Reports of two cases of difficult intubation.
    Midttun M; Laerkholm Hansen C; Jensen K; Pedersen T
    Acta Anaesthesiol Scand; 1994 Apr; 38(3):300-2. PubMed ID: 8023673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of nasotracheal Airtraq® laryngoscope with reinforced endotracheal tube: our experience.
    Ferrari F; Marchetti G; Picardo SG
    Paediatr Anaesth; 2014 Aug; 24(8):890-1. PubMed ID: 25039879
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A comparison of Airtraq™ laryngoscope and standard direct laryngoscopy in adult patients with immobilized cervical spine].
    Amor M; Nabil S; Bensghir M; Moussaoui A; Kabbaj S; Kamili ND; Maazouzi W
    Ann Fr Anesth Reanim; 2013 May; 32(5):296-301. PubMed ID: 23561715
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective model-based comparison of different laryngoscopes for difficult intubation in infants.
    Kalbhenn J; Boelke AK; Steinmann D
    Paediatr Anaesth; 2012 Aug; 22(8):776-80. PubMed ID: 22646973
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of a plastic optical fiber stylet for tracheal intubation of a dog.
    Gravenstein D; Lampotang S; Melker R; Doviak R
    J Clin Monit Comput; 1998 May; 14(4):271-4. PubMed ID: 9754616
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope.
    Serocki G; Bein B; Scholz J; Dörges V
    Eur J Anaesthesiol; 2010 Jan; 27(1):24-30. PubMed ID: 19809328
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Difficult fiber-optic intubation in a patient with giant neck masses: The role of McCoy laryngoscope in elevating compressed laryngeal aperture.
    Yeh L; Chen HS; Tan PH; Liu PH; Hsieh SW; Hung KC
    Acta Anaesthesiol Taiwan; 2013 Dec; 51(4):180-3. PubMed ID: 24529675
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of Bullard laryngoscope and short-handled Macintosh laryngoscope for orotracheal intubation in pediatric patients with simulated restriction of cervical spine movements.
    Nileshwar A; Garg V
    Paediatr Anaesth; 2010 Dec; 20(12):1092-7. PubMed ID: 21199118
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The use of a plastic guide improves the safety and reduces the duration of endotracheal intubation in the pig.
    Janiszewski A; Pasławski R; Skrzypczak P; Pasławska U; Szuba A; Nicpoń J
    J Vet Med Sci; 2014 Oct; 76(10):1317-20. PubMed ID: 24931644
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study.
    Koyama Y; Inagawa G; Miyashita T; Kikuchi T; Miura N; Miki T; Kurihara R; Kamiya Y; Goto T
    Anaesthesia; 2007 Sep; 62(9):936-9. PubMed ID: 17697222
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.