21. Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures.
Kuon E; Glaser C; Dahm JB
Br J Radiol; 2003 Jun; 76(906):406-13. PubMed ID: 12814927
[TBL] [Abstract][Full Text] [Related]
22. Patient dose in cardiac radiology.
Stratis AI; Anthopoulos PL; Gavaliatsis IP; Ifantis GP; Salahas AI; Antonellis IP; Tavernarakis AG; Molfetas MI
Hellenic J Cardiol; 2009; 50(1):17-25. PubMed ID: 19196617
[TBL] [Abstract][Full Text] [Related]
23. Radiation exposure to patients undergoing percutaneous coronary interventions: are current reference values too high?
Kuon E; Empen K; Rohde D; Dahm JB
Herz; 2004 Mar; 29(2):208-17. PubMed ID: 15054590
[TBL] [Abstract][Full Text] [Related]
24. Overall measurements of dose to patients in common interventional cardiology procedures.
Wang W; Zhang M; Zhang Y
Radiat Prot Dosimetry; 2013 Dec; 157(3):348-54. PubMed ID: 23770572
[TBL] [Abstract][Full Text] [Related]
25. Assessment of radiation protection of patients and staff in interventional procedures in four Algerian hospitals.
Khelassi-Toutaoui N; Toutaoui A; Merad A; Sakhri-Brahimi Z; Baggoura B; Mansouri B
Radiat Prot Dosimetry; 2016 Jan; 168(1):55-60. PubMed ID: 25646525
[TBL] [Abstract][Full Text] [Related]
26. Patient dosimetry approaches in interventional cardiology and literature dose data review.
Padovani R; Quai E
Radiat Prot Dosimetry; 2005; 117(1-3):217-21. PubMed ID: 16461496
[TBL] [Abstract][Full Text] [Related]
27. Radiation dose levels during interventional cardiology procedures in a tertiary care hospital.
Dragusin O; Desmet W; Heidbuchel H; Padovani R; Bosmans H
Radiat Prot Dosimetry; 2005; 117(1-3):231-5. PubMed ID: 16461493
[TBL] [Abstract][Full Text] [Related]
28. An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures.
Morrish OW; Goldstone KE
Br J Radiol; 2008 Jan; 81(961):35-45. PubMed ID: 18039722
[TBL] [Abstract][Full Text] [Related]
29. High patient doses in interventional cardiology due to physicians' negligence: how can they be prevented?
Mavrikou I; Kottou S; Tsapaki V; Neofotistou V
Radiat Prot Dosimetry; 2008; 129(1-3):67-70. PubMed ID: 18337290
[TBL] [Abstract][Full Text] [Related]
30. Patient doses in interventional cardiology procedures in Sudan.
Ahmed NA; Ibraheem SB; Habbani FI
Radiat Prot Dosimetry; 2013; 153(4):425-30. PubMed ID: 22791837
[TBL] [Abstract][Full Text] [Related]
31. A study on patients' radiation doses from interventional cardiac procedures in Tabriz, Iran.
Mesbahi A; Aslanabadi N
Radiat Prot Dosimetry; 2008; 132(4):375-80. PubMed ID: 19106178
[TBL] [Abstract][Full Text] [Related]
32. Reference levels at European level for cardiac interventional procedures.
Padovani R; Vano E; Trianni A; Bokou C; Bosmans H; Bor D; Jankowski J; Torbica P; Kepler K; Dowling A; Milu C; Tsapaki V; Salat D; Vassileva J; Faulkner K
Radiat Prot Dosimetry; 2008; 129(1-3):104-7. PubMed ID: 18310612
[TBL] [Abstract][Full Text] [Related]
33. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values.
Ubeda C; Miranda P; Vano E
Med Phys; 2015 Feb; 42(2):615-622. PubMed ID: 28102608
[TBL] [Abstract][Full Text] [Related]
34. Assessment of peak skin dose in interventional cardiology: A comparison between Gafchromic film and dosimetric software em.dose.
Greffier J; Van Ngoc Ty C; Bonniaud G; Moliner G; Ledermann B; Schmutz L; Cornillet L; Cayla G; Beregi JP; Pereira F
Phys Med; 2017 Jun; 38():16-22. PubMed ID: 28610693
[TBL] [Abstract][Full Text] [Related]
35. [Variations of radiation dosage delivered to patients undergoing interventional cardiological procedures. A monocentric study 2002-05].
Georges JL; Livarek B; Gibault-Genty G; Messaoudi H; Aziza JP; Hautecoeur JL; Soleille H
Arch Mal Coeur Vaiss; 2007 Mar; 100(3):175-81. PubMed ID: 17536420
[TBL] [Abstract][Full Text] [Related]
36. Personnel doses in haemodynamic units in Greece.
Kottou S; Neofotistou V; Tsapaki V; Lobotessi H; Manetou A; Molfetas MG
Radiat Prot Dosimetry; 2001; 94(1-2):121-4. PubMed ID: 11487818
[TBL] [Abstract][Full Text] [Related]
37. Updating national diagnostic reference levels for interventional cardiology and methodological aspects.
Sánchez R; Vañó E; Fernández Soto JM; Ten JI; Escaned J; Delgado C; García B; Carrera Magariño F; Fernández JFD; Luna RJM; Moreno MAR; Catalán A; Ojeda FB; Rosales Espizua FJ; Moreno JRS; Pifarré X; Goicolea J; Ordiales JM; Nogales JM; Martinez G; García P; Benedicto A; Castillo MFR; Torres LP; Font J; Bethencourt A; Cesteros MJ; Pérez A; Pinar E; Tobarra B
Phys Med; 2020 Feb; 70():169-175. PubMed ID: 32032801
[TBL] [Abstract][Full Text] [Related]
38. Coronary angiography and percutaneous transluminal coronary angioplasty procedures: Evaluation of patients' maximum skin dose using Gafchromic films and a comparison of local levels with reference levels proposed in the literature.
Giordano C; D'Ercole L; Gobbi R; Bocchiola M; Passerini F
Phys Med; 2010 Oct; 26(4):224-32. PubMed ID: 20117030
[TBL] [Abstract][Full Text] [Related]
39. Occupational dose constraints in interventional cardiology procedures: the DIMOND approach.
Tsapaki V; Kottou S; Vano E; Komppa T; Padovani R; Dowling A; Molfetas M; Neofotistou V
Phys Med Biol; 2004 Mar; 49(6):997-1005. PubMed ID: 15104322
[TBL] [Abstract][Full Text] [Related]
40. An estimate of the collective dose to the European population from cardiac X-ray procedures.
Faulkner K; Werduch A
Br J Radiol; 2008 Dec; 81(972):955-62. PubMed ID: 19029053
[TBL] [Abstract][Full Text] [Related]