These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus Andersen cascade impactor and low-flow Marple personal cascade impactor. Kwong WT; Ho SL; Coates AL J Aerosol Med; 2000; 13(4):303-14. PubMed ID: 11262437 [TBL] [Abstract][Full Text] [Related]
3. Determination of nebulizer droplet size distribution: a method based on impactor refrigeration. Berg E; Svensson JO; Asking L J Aerosol Med; 2007; 20(2):97-104. PubMed ID: 17536948 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a new Aerodynamic Particle Sizer Spectrometer for size distribution measurements of solution metered dose inhalers. Stein SW; Myrdal PB; Gabrio BJ; Obereit D; Beck TJ J Aerosol Med; 2003; 16(2):107-19. PubMed ID: 12823905 [TBL] [Abstract][Full Text] [Related]
5. Aerodynamic particle size analysis of aerosols from pressurized metered-dose inhalers: comparison of Andersen 8-stage cascade impactor, next generation pharmaceutical impactor, and model 3321 Aerodynamic Particle Sizer aerosol spectrometer. Mitchell JP; Nagel MW; Wiersema KJ; Doyle CC AAPS PharmSciTech; 2003 Oct; 4(4):E54. PubMed ID: 15198549 [TBL] [Abstract][Full Text] [Related]
6. Aerosol delivery of recombinant human DNase I: in vitro comparison of a vibrating-mesh nebulizer with a jet nebulizer. Johnson JC; Waldrep JC; Guo J; Dhand R Respir Care; 2008 Dec; 53(12):1703-8. PubMed ID: 19025706 [TBL] [Abstract][Full Text] [Related]
8. Effect of tubing deposition, breathing pattern, and temperature on aerosol mass distribution measured by cascade impactor. Gurses BK; Smaldone GC J Aerosol Med; 2003; 16(4):387-94. PubMed ID: 14977429 [TBL] [Abstract][Full Text] [Related]
9. Standardization issues: in vitro assessment of nebulizer performance. Dennis JH Respir Care; 2002 Dec; 47(12):1445-55; discussion 1455-8. PubMed ID: 12467502 [TBL] [Abstract][Full Text] [Related]
10. Reconciliation of Cascade Impaction during Wet Nebulization. Solomita M; Smaldone GC J Aerosol Med Pulm Drug Deliv; 2009 Mar; 22(1):11-8. PubMed ID: 19392585 [TBL] [Abstract][Full Text] [Related]
11. Laser diffractometry and cascade impaction for nebulizer product characterization. Mitchell JP; Tservistas M Pharmeur Sci Notes; 2006 Dec; 2006(2):49-52. PubMed ID: 17691215 [TBL] [Abstract][Full Text] [Related]
12. Influence of realistic airflow rate on aerosol generation by nebulizers. Vecellio L; Kippax P; Rouquette S; Diot P Int J Pharm; 2009 Apr; 371(1-2):99-105. PubMed ID: 19150494 [TBL] [Abstract][Full Text] [Related]
13. Aerodynamic characteristics of nebulized terbutaline sulphate using the Next Generation Impactor (NGI) and CEN method. Abdelrahim ME; Chrystyn H J Aerosol Med Pulm Drug Deliv; 2009 Mar; 22(1):19-28. PubMed ID: 19392586 [TBL] [Abstract][Full Text] [Related]
14. Output and aerosol properties of 5 nebulizer/compressor systems with arformoterol inhalation solution. Bauer A; McGlynn P; Bovet LL; Mims PL; Curry LA; Hanrahan JP Respir Care; 2009 Oct; 54(10):1342-7. PubMed ID: 19796414 [TBL] [Abstract][Full Text] [Related]
15. Comparison of laser diffraction measurements by Mastersizer X and Spraytec to characterize droplet size distribution of medical liquid aerosols. Lelong N; Junqua-Moullet A; Diot P; Vecellio L J Aerosol Med Pulm Drug Deliv; 2014 Apr; 27(2):94-102. PubMed ID: 23668547 [TBL] [Abstract][Full Text] [Related]
16. Correlations between cascade impactor analysis and laser diffraction techniques for the determination of the particle size of aerosolised powder formulations. Pilcer G; Vanderbist F; Amighi K Int J Pharm; 2008 Jun; 358(1-2):75-81. PubMed ID: 18359587 [TBL] [Abstract][Full Text] [Related]
17. Comparison of cascade impaction and laser diffraction for particle size distribution measurements. Ziegler J; Wachtel H J Aerosol Med; 2005; 18(3):311-24. PubMed ID: 16181006 [TBL] [Abstract][Full Text] [Related]
18. Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI. Song X; Hu J; Zhan S; Zhang R; Tan W AAPS PharmSciTech; 2016 Apr; 17(2):380-8. PubMed ID: 26169901 [TBL] [Abstract][Full Text] [Related]
19. In vitro evaluation of positive expiratory pressure devices attached to nebulizers. Berlinski A Respir Care; 2014 Feb; 59(2):216-22. PubMed ID: 23920213 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of preseparator performance for the 8-stage nonviable andersen impactor. Sethuraman VV; Hickey AJ AAPS PharmSciTech; 2001 Mar; 2(1):E4. PubMed ID: 14727889 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]