155 related articles for article (PubMed ID: 11503125)
1. Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty.
Novotny J; Gonzalez MH; Amirouche FM; Li YC
J Arthroplasty; 2001 Aug; 16(5):641-7. PubMed ID: 11503125
[TBL] [Abstract][Full Text] [Related]
2. The variability of intramedullary alignment of the femoral component during total knee arthroplasty.
Mihalko WM; Boyle J; Clark LD; Krackow KA
J Arthroplasty; 2005 Jan; 20(1):25-8. PubMed ID: 15660056
[TBL] [Abstract][Full Text] [Related]
3. The accuracy of femoral intramedullary guides in total knee arthroplasty.
Reed SC; Gollish J
J Arthroplasty; 1997 Sep; 12(6):677-82. PubMed ID: 9306219
[TBL] [Abstract][Full Text] [Related]
4. Proper entry point for femoral intramedullary guide in total knee arthroplasty.
Wangroongsub Y; Cherdtaweesup S
J Med Assoc Thai; 2009 Dec; 92 Suppl 6():S1-5. PubMed ID: 20128068
[TBL] [Abstract][Full Text] [Related]
5. Extramedullary versus intramedullary alignment guides in total knee arthroplasty.
Ishii Y; Ohmori G; Bechtold JE; Gustilo RB
Clin Orthop Relat Res; 1995 Sep; (318):167-75. PubMed ID: 7671512
[TBL] [Abstract][Full Text] [Related]
6. Distal femoral resection at knee replacement - the effect of varying entry point and rotation on prosthesis position.
Gangadharan R; Deehan DJ; McCaskie AW
Knee; 2010 Oct; 17(5):345-9. PubMed ID: 19875296
[TBL] [Abstract][Full Text] [Related]
7. Alignment of resection planes in total knee replacement obtained with the conventional technique, as assessed by a modern computer-based navigation system.
Belvedere C; Ensini A; Leardini A; Bianchi L; Catani F; Giannini S
Int J Med Robot; 2007 Jun; 3(2):117-24. PubMed ID: 17619241
[TBL] [Abstract][Full Text] [Related]
8. Femoral Intramedullary Alignment in Total Knee Arthroplasty: Indications, Results, Pitfalls, Alternatives, and Controversies.
Bono OJ; Olcott CW; Carangelo R; Jamison JP; Tigges RG; Talmo CT; Bono JV
J Knee Surg; 2020 Jan; 33(1):12-14. PubMed ID: 30544271
[TBL] [Abstract][Full Text] [Related]
9. Instrumentation pitfalls: you just can't go on autopilot!
Laskin RS
J Arthroplasty; 2003 Apr; 18(3 Suppl 1):18-22. PubMed ID: 12730922
[TBL] [Abstract][Full Text] [Related]
10. A navigated 8-in-1 femoral cutting guide for total knee arthroplasty technical development and cadaveric evaluation.
Kendoff DO; Moreau-Gaudry A; Plaskos C; Granchi C; Sculco TP; Pearle AD
J Arthroplasty; 2010 Jan; 25(1):138-45. PubMed ID: 19106033
[TBL] [Abstract][Full Text] [Related]
11. Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty.
Ma B; Long W; Rudan JF; Ellis RE
J Arthroplasty; 2006 Feb; 21(2):271-8. PubMed ID: 16520218
[TBL] [Abstract][Full Text] [Related]
12. Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study.
Yau WP; Leung A; Liu KG; Yan CH; Wong LS; Chiu KY
J Bone Joint Surg Br; 2008 Apr; 90(4):520-6. PubMed ID: 18378933
[TBL] [Abstract][Full Text] [Related]
13. Posteriorly offset femoral component to restore anteroposterior position of the distal femur in revision total knee arthroplasty.
Brilhault JM; Ries MD
J Arthroplasty; 2011 Feb; 26(2):214-7. PubMed ID: 20570092
[TBL] [Abstract][Full Text] [Related]
14. The effect of component placement on knee kinetics after arthroplasty with an unconstrained prosthesis.
Miller MC; Zhang AX; Petrella AJ; Berger RA; Rubash HE
J Orthop Res; 2001 Jul; 19(4):614-20. PubMed ID: 11518270
[TBL] [Abstract][Full Text] [Related]
15. [Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty].
Michaut M; Beaufils P; Galaud B; Abadie P; Boisrenoult P; Fallet L
Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):580-4. PubMed ID: 18929753
[TBL] [Abstract][Full Text] [Related]
16. Gender differences in the distal femur dimensions and variation patterns in relation to TKA component sizing.
Rosenstein AD; Veazey B; Shephard D; Xu KT
Orthopedics; 2008 Jul; 31(7):652. PubMed ID: 19292386
[TBL] [Abstract][Full Text] [Related]
17. How accurate is Whiteside's line as a reference axis in total knee arthroplasty?
Middleton FR; Palmer SH
Knee; 2007 Jun; 14(3):204-7. PubMed ID: 17428665
[TBL] [Abstract][Full Text] [Related]
18. Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: a study in 10 cadaver femora.
Kort NP; van Raay JJ; Thomassen BJ
Knee; 2007 Aug; 14(4):280-3. PubMed ID: 17543531
[TBL] [Abstract][Full Text] [Related]
19. [The effect of rotational alignment of the femoral components on the patellofemoral biomechanics in total knee arthroplasty].
Chu XB; Wu HS; Xu CM; Zhu YL; Feng MG; He ZY
Zhonghua Wai Ke Za Zhi; 2006 Aug; 44(16):1136-40. PubMed ID: 17081473
[TBL] [Abstract][Full Text] [Related]
20. Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty.
Nam D; Jerabek SA; Cross MB; Mayman DJ
Comput Aided Surg; 2012; 17(4):205-10. PubMed ID: 22681247
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]