These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 11506470)

  • 1. Protein G ELISA for the detection of circulating immune complexes. An alternative to the solid-phase radioimmunoassay for the monoclonal rheumatoid factor.
    Van Hoeyveld E; Willebrods L; Bossuyt X
    Clin Chem Lab Med; 2001 Jun; 39(6):562-4. PubMed ID: 11506470
    [No Abstract]   [Full Text] [Related]  

  • 2. IgE rheumatoid factor. Occurrence and diagnostic importance in comparison with IgM rheumatoid factor and circulating immune complexes.
    Herrmann D; Jäger L; Hein G; Henzgen M; Schlenvoigt G
    J Investig Allergol Clin Immunol; 1991 Oct; 1(5):302-7. PubMed ID: 1669588
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of seven commercial ELISA kits compared with the C1q solid-phase binding RIA for detection of circulating immune complexes.
    Van Hoeyveld E; Bossuyt X
    Clin Chem; 2000 Feb; 46(2):283-5. PubMed ID: 10657388
    [No Abstract]   [Full Text] [Related]  

  • 4. Comparison of a pneumococcal common protein (PsaA) antibody ELISA and a PsaA immune complex ELISA for detection of pneumococcal serum antibody.
    Tharpe JA; Russell H; Leinonen M; Plikaytis BD; Breiman RF; Carlone GM; Ades EW; Sampson JS
    Pathobiology; 1998; 66(2):77-83. PubMed ID: 9645631
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of six tests for circulating IgG complexes with special reference to IgM rheumatoid factors: analysis of systemic lupus erythematosus and rheumatoid arthritis series.
    Wager O; Lindström P; Räsänen JA; Kekomäki R; Ziola B; Salmi A; Isomäki H; Skrifvars B; Penttinen K
    Clin Exp Immunol; 1981 Oct; 46(1):149-60. PubMed ID: 7337967
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Measurement of immune complexes: monoclonal rheumatoid factor method].
    Hidaka Y
    Nihon Rinsho; 2010 Jun; 68 Suppl 6():119-21. PubMed ID: 20942017
    [No Abstract]   [Full Text] [Related]  

  • 7. A radioimmunoassay for human antigen-antibody complexes in clinical material.
    Cowdery JS; Treadwell PE; Fritz RB
    J Immunol; 1975 Jan; 114(1 Pt 1):5-9. PubMed ID: 1167561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Immune complexes, rheumatoid factors, and cellular immunological parameters in patients with giant cell arteritis.
    Malmvall BE; Bengtsson BA; Nilsson LA; Bjursten LM
    Ann Rheum Dis; 1981 Jun; 40(3):276-80. PubMed ID: 6972741
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Role of IgM-rheumatoid factor interference in the determination of total serum IgE and IgE-containing circulating immune complexes.
    De Clerck LS; Gigase PL; Bridts CH; Stevens WJ
    Clin Exp Immunol; 1988 Apr; 72(1):32-6. PubMed ID: 3396220
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of circulating immune complexes in cutaneous disease using a monoclonal rheumatoid factor hemagglutination method.
    Jordon RE; Mackel SE; Brumfield H
    J Clin Lab Immunol; 1981 Jul; 6(1):87-90. PubMed ID: 6790707
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of IgE rheumatoid factor. Comparison of a solid-phase radioimmunoassay and an enzyme immunoassay.
    Herrmann D; Schlenvoigt G; Jäger L
    Allerg Immunol (Leipz); 1987; 33(2):101-9. PubMed ID: 2959124
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An enzyme-linked immunoassay for detection of IgG- and C3-containing circulating immune complexes: comparison with a radioimmunoassay and quantitation in patients with rheumatic diseases.
    Panush RS; Somberg LB; Katz P; Longley S
    Diagn Immunol; 1983; 1(4):288-94. PubMed ID: 6388973
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Enzyme therapy in comparison with immune complex determinations in chronic polyarthritis].
    Steffen C; Smolen J; Miehlke K; Hörger I; Menzel J
    Z Rheumatol; 1985; 44(2):51-6. PubMed ID: 4050140
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of immune-complex size and antigen-antibody ratio on immune complex detection with monoclonal rheumatoid factor and C1q.
    Vanham G; Bloemmen FJ; Ceuppens JL; Stevens EA
    J Clin Lab Immunol; 1984 Oct; 15(2):63-8. PubMed ID: 6335179
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Circulating immune complexes in rheumatoid arthritis--their association with IgM rheumatoid factor, anatomical stages and functional classes].
    Sakurai T; Kono I; Kabashima T; Yamane K; Kashiwagi H
    Ryumachi; 1985 Apr; 25(2):81-6. PubMed ID: 4035468
    [No Abstract]   [Full Text] [Related]  

  • 16. A polyclonal IgM-RF enzyme-linked immunosorbent assay for the detection of circulating immune complexes.
    Bukh A; Thomsen BS; Kimose HH; Nielsen LR; Svehag SE; Møller NP
    J Clin Lab Immunol; 1988 Aug; 26(4):195-200. PubMed ID: 3199429
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Circulating immune complexes and complement in rheumatoid arthritis.
    Duquesnoy B
    Ann Biol Clin (Paris); 1984; 42(1):71-5. PubMed ID: 6375473
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Use of solid-phase Clq-ELISA for detecting circulating immune complexes in human diseases].
    Aleshkin VA; Nasonov EL; Eremeeva MV; Kobylianskiĭ AG
    Ter Arkh; 1989; 61(6):113-6. PubMed ID: 2477907
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The measurement of circulating immune complexes using anti-C3 antibody micro ELISA].
    Hayashi S; Aochi H; Nagamine K; Oshida M; Kurata Y; Kawagoe H
    Rinsho Byori; 1986 Dec; 34(12):1408-12. PubMed ID: 3560472
    [No Abstract]   [Full Text] [Related]  

  • 20. [Determination of circulating immune complexes and of their component immunoglobulin classes M, G, and A with a C1q-ELISA].
    Sequeira Peña GA; Herrmann D; Vogt KH; Jäger L
    Allerg Immunol (Leipz); 1991; 37(1):37-45. PubMed ID: 2063729
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.