These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
106 related articles for article (PubMed ID: 11509274)
41. Profound systemic hypothermia protects the spinal cord in a primate model of spinal cord ischemia. Rokkas CK; Sundaresan S; Shuman TA; Palazzo RS; Nitta T; Despotis GJ; Burns TC; Wareing TH; Kouchoukos NT J Thorac Cardiovasc Surg; 1993 Dec; 106(6):1024-35. PubMed ID: 8246534 [TBL] [Abstract][Full Text] [Related]
42. Development of Collaterals to the Spinal Cord after Endovascular Stent Graft Repair of Thoracic Aneurysms. Fukui S; Tanaka H; Kobayashi K; Kajiyama T; Mitsuno M; Yamamura M; Ryomoto M; Miyamoto Y Eur J Vasc Endovasc Surg; 2016 Dec; 52(6):801-807. PubMed ID: 27776939 [TBL] [Abstract][Full Text] [Related]
43. New surgical techniques for the prevention of paraplegia during aortic surgery. Wadouh F Thorac Cardiovasc Surg; 1992 Feb; 40(1):26-32. PubMed ID: 1631862 [TBL] [Abstract][Full Text] [Related]
44. Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. I. Relationship of aortic cross-clamp duration, changes in somatosensory evoked potentials, and incidence of neurologic dysfunction. Laschinger JC; Cunningham JN; Cooper MM; Baumann FG; Spencer FC J Thorac Cardiovasc Surg; 1987 Aug; 94(2):260-5. PubMed ID: 3613625 [TBL] [Abstract][Full Text] [Related]
45. The effect of hyperemia on spinal cord function after temporary thoracic aortic occlusion. Barone GW; Joob AW; Flanagan TL; Dunn CE; Kron IL J Vasc Surg; 1988 Oct; 8(4):535-40. PubMed ID: 3172389 [TBL] [Abstract][Full Text] [Related]
46. Prevention of spinal cord injury after cross-clamping of the thoracic aorta. Oka Y; Miyamoto T J Cardiovasc Surg (Torino); 1987; 28(4):398-404. PubMed ID: 3597535 [TBL] [Abstract][Full Text] [Related]
47. Intraluminal shunt for the thoracic aorta: spinal cord and visceral blood flow in acute studies. Van Voorst SJ; Rustom S; Pate JW; Maijub AG; Leffler CW World J Surg; 1994; 18(6):939-43. PubMed ID: 7846923 [TBL] [Abstract][Full Text] [Related]
48. Evaluation of collateral network near-infrared spectroscopy during and after segmental artery occlusion in a chronic large animal model. von Aspern K; Haunschild J; Ziemann M; Misfeld M; Mohr FW; Borger MA; Etz CD J Thorac Cardiovasc Surg; 2019 Jul; 158(1):155-164.e5. PubMed ID: 30686484 [TBL] [Abstract][Full Text] [Related]
49. Iloprost protects the spinal cord during aortic cross-clamping in a canine model. Katircioglu SF; Ulus AT; Gökçe P; Sürücü S J Cardiovasc Surg (Torino); 2000 Feb; 41(1):89-93. PubMed ID: 10836230 [TBL] [Abstract][Full Text] [Related]
50. Low-flow lower body perfusion for spinal protection in a frozen elephant trunk simulation model. Haldenwang PL; Häuser L; Prochnow N; Ziebura D; Baumann A; Sikole M; Schlömicher M; Schmitz I; Christ H; Strauch JT Eur J Cardiothorac Surg; 2016 Nov; 50(5):963-970. PubMed ID: 27174550 [TBL] [Abstract][Full Text] [Related]
51. Adequacy of ascending aorta-descending aorta shunt during cross-clamping of the thoracic aorta for prevention of spinal cord injury. Molina JE; Cogordan J; Einzig S; Bianco RW; Rasmussen T; Clack RM; Borgwardt B J Thorac Cardiovasc Surg; 1985 Jul; 90(1):126-36. PubMed ID: 4010314 [TBL] [Abstract][Full Text] [Related]
52. Operative strategy for descending and thoracoabdominal aneurysm repair with preoperative demonstration of the Adamkiewicz artery. Furukawa K; Kamohara K; Nojiri J; Egashira Y; Okazaki Y; Kudo S; Morita S Ann Thorac Surg; 2010 Dec; 90(6):1840-6. PubMed ID: 21095322 [TBL] [Abstract][Full Text] [Related]
53. Importance of extrasegmental vessels for spinal cord blood supply in a chronic porcine model. Strauch JT; Spielvogel D; Lauten A; Zhang N; Shiang H; Weisz D; Bodian CA; Griepp RB Rev Port Cir Cardiotorac Vasc; 2003; 10(4):185-91. PubMed ID: 15146254 [TBL] [Abstract][Full Text] [Related]
54. Protective effect of prostaglandin E1 against ischemia of spinal cord during aortic cross clamping. Fukumoto Y; Mori Y; Takagi H; Iwata H; Umeda Y; Hirose H J Vasc Surg; 2003 Jan; 37(1):156-60. PubMed ID: 12514594 [TBL] [Abstract][Full Text] [Related]
55. Neuroanesthesia adjunct therapy (mannitol and hyperventilation) is as effective as cerebrospinal fluid drainage for prevention of paraplegia after descending thoracic aortic cross-clamping in the dog. Mutch WA; Thiessen DB; Girling LG; Graham MR Anesth Analg; 1995 Oct; 81(4):800-5. PubMed ID: 7574013 [TBL] [Abstract][Full Text] [Related]
56. Spinal cord protection with selective spinal perfusion during descending thoracic and thoracoabdominal aortic surgery. Kawaharada N; Ito T; Koyanagi T; Harada R; Hyodoh H; Kurimoto Y; Watanabe A; Higami T Interact Cardiovasc Thorac Surg; 2010 Jun; 10(6):986-90; discussion 990-1. PubMed ID: 20233810 [TBL] [Abstract][Full Text] [Related]
57. Comparison studies of passive and active shunting during cross-clamping of the descending thoracic aorta. Liu G; Orihashi K; Shikata H; Murakami H; Fukunaga S; Sueda T; Matsuura Y Panminerva Med; 1994 Dec; 36(4):160-7. PubMed ID: 7603731 [TBL] [Abstract][Full Text] [Related]
58. [Prevention of spinal cord ischemia after cross-clamping of the thoracic aorta--monitoring of spinal cord perfusion pressure and somatosensory evoked potentials]. Maeda S; Miyamoto T; Murata H; Yamashita K; Iwaoka S; Yasuoka T; Hara Y; Ueda T Nihon Kyobu Geka Gakkai Zasshi; 1989 Sep; 37(9):1923-31. PubMed ID: 2600466 [TBL] [Abstract][Full Text] [Related]
59. The mechanism of spinal cord injury after simple and double aortic cross-clamping. Wadouh F; Arndt CF; Oppermann E; Borst HG; Wadouh R J Thorac Cardiovasc Surg; 1986 Jul; 92(1):121-7. PubMed ID: 3724215 [TBL] [Abstract][Full Text] [Related]
60. [New non-invasive Doppler ultrasound study of blood flow in segmental arteries]. Afonin DN; Afonin PN Med Tekh; 2002; (3):7-10. PubMed ID: 12224255 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]