These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
198 related articles for article (PubMed ID: 11511029)
1. Isolation and morphological characterisation of UHMWPE wear debris generated in vitro. Affatato S; Fernandes B; Tucci A; Esposito L; Toni A Biomaterials; 2001 Sep; 22(17):2325-31. PubMed ID: 11511029 [TBL] [Abstract][Full Text] [Related]
2. Mixed oxides prosthetic ceramic ball heads. Part 1: effect of the ZrO2 fraction on the wear of ceramic on polythylene joints. Affatato S; Testoni M; Cacciari GL; Toni A Biomaterials; 1999 May; 20(10):971-5. PubMed ID: 10353651 [TBL] [Abstract][Full Text] [Related]
3. Mixed oxides prosthetic ceramic ball heads. Part 3: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses. A long-term in vitro wear study. Affatato S; Goldoni M; Testoni M; Toni A Biomaterials; 2001 Apr; 22(7):717-23. PubMed ID: 11246966 [TBL] [Abstract][Full Text] [Related]
4. The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols. Affatato S; Bersaglia G; Emiliani D; Foltran I; Taddei P; Reggiani M; Ferrieri P; Toni A Biomaterials; 2003 Oct; 24(22):4045-55. PubMed ID: 12834600 [TBL] [Abstract][Full Text] [Related]
5. Hip simulator wear testing according to the newly introduced standard ISO 14242. Kaddick C; Wimmer MA Proc Inst Mech Eng H; 2001; 215(5):429-42. PubMed ID: 11726043 [TBL] [Abstract][Full Text] [Related]
6. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Goldsmith AA; Dowson D; Isaac GH; Lancaster JG Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049 [TBL] [Abstract][Full Text] [Related]
7. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821 [TBL] [Abstract][Full Text] [Related]
8. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions. Wang A; Essner A; Stark C; Dumbleton JH Biomaterials; 1996 May; 17(9):865-71. PubMed ID: 8718931 [TBL] [Abstract][Full Text] [Related]
9. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator. Smith SL; Unsworth A Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696 [TBL] [Abstract][Full Text] [Related]
10. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. Saikko V; Calonius O; Keränen J J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033 [TBL] [Abstract][Full Text] [Related]
11. Scanning Electron Microscopy and Energy-Dispersive X-Ray Spectroscopy as a Valuable Tool to Investigate the Ultra-High-Molecular-Weight Polyethylene Wear Mechanisms and Debris in Hip Implants. Schappo H; Gindri IM; Cubillos PO; Maru MM; Salmoria GV; Roesler CRM J Arthroplasty; 2018 Jan; 33(1):258-262. PubMed ID: 28844766 [TBL] [Abstract][Full Text] [Related]
12. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055 [TBL] [Abstract][Full Text] [Related]
13. Alumina-alumina artificial hip joints. Part II: characterisation of the wear debris from in vitro hip joint simulations. Tipper JL; Hatton A; Nevelos JE; Ingham E; Doyle C; Streicher R; Nevelos AB; Fisher J Biomaterials; 2002 Aug; 23(16):3441-8. PubMed ID: 12099287 [TBL] [Abstract][Full Text] [Related]
14. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418 [TBL] [Abstract][Full Text] [Related]
15. Wear characteristics of ceramic-on-ceramic for hip endoprostheses. Früh HJ; Willmann G; Pfaff HG Biomaterials; 1997 Jun; 18(12):873-6. PubMed ID: 9184751 [TBL] [Abstract][Full Text] [Related]
16. An in vitro wear study of alumina-alumina total hip prostheses. Smith SL; Unsworth A Proc Inst Mech Eng H; 2001; 215(5):443-6. PubMed ID: 11726044 [TBL] [Abstract][Full Text] [Related]
17. Frictional heating of bearing materials tested in a hip joint wear simulator. Lu Z; McKellop H Proc Inst Mech Eng H; 1997; 211(1):101-8. PubMed ID: 9141895 [TBL] [Abstract][Full Text] [Related]
18. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon. Saikko V; Ahlroos T; Calonius O; Keränen J Biomaterials; 2001 Jun; 22(12):1507-14. PubMed ID: 11374449 [TBL] [Abstract][Full Text] [Related]
19. Wear of polyethylene acetabular cups against alumina femoral heads. 5 prostheses compared in a hip simulator for 35 million walking cycles. Saikko VO Acta Orthop Scand; 1993 Oct; 64(5):507-12. PubMed ID: 8237313 [TBL] [Abstract][Full Text] [Related]
20. Mixed-oxides prosthetic ceramic ball heads. Part 2: effect of the ZrO2 fraction on the wear of ceramic on ceramic joints. Affatato S; Testoni M; Cacciari GL; Toni A Biomaterials; 1999 Oct; 20(20):1925-9. PubMed ID: 10514069 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]