These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

67 related articles for article (PubMed ID: 11512280)

  • 1. [Respiratory filters and pneumonia: many unresolved questions].
    Gastmeier P; Beck KD; Lode H
    Dtsch Med Wochenschr; 2001 Jul; 126(30):835-9. PubMed ID: 11512280
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The clinical and microbiological comparison of the use of heated humidifiers and heat and moisture exchanger filters with Booster in mechanically ventilated patients].
    Nadir Oziş T; Ozcan Kanat D; Oğuzülgen IK; Aydoğdu M; Hizel K; Gürsel G
    Tuberk Toraks; 2009; 57(3):259-67. PubMed ID: 19787464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion.
    Kirton OC; DeHaven B; Morgan J; Morejon O; Civetta J
    Chest; 1997 Oct; 112(4):1055-9. PubMed ID: 9377917
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Humidification assessment of four heat and moisture exchanger filters according to ISO 9360: 2000 standard].
    Lannoy D; Décaudin B; Resibois JP; Barrier F; Wierre L; Horrent S; Batt C; Moulront S; Odou P
    Ann Fr Anesth Reanim; 2008 Feb; 27(2):148-53. PubMed ID: 18164895
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
    Thomachot L; Vialet R; Arnaud S; Barberon B; Michel-Nguyen A; Martin C
    Crit Care Med; 1999 May; 27(5):923-8. PubMed ID: 10362414
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A heat and moisture exchanging filter in long-term ventilation.
    Sidhu VS; Henderson SJ; Allt-Graham J
    Clin Intensive Care; 1994; 5(6):289-92. PubMed ID: 10150556
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial.
    Lacherade JC; Auburtin M; Cerf C; Van de Louw A; Soufir L; Rebufat Y; Rezaiguia S; Ricard JD; Lellouche F; Brun-Buisson C; Brochard L
    Am J Respir Crit Care Med; 2005 Nov; 172(10):1276-82. PubMed ID: 16126933
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Heat and moisture exchanging filters for conditioning of inspired gases in adult anesthesia and resuscitation].
    Subayi L; Chergui K; Beydon L
    Ann Fr Anesth Reanim; 1998; 17(7):699-708. PubMed ID: 9750808
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia.
    Thomachot L; Viviand X; Arnaud S; Boisson C; Martin CD
    Chest; 1998 Nov; 114(5):1383-9. PubMed ID: 9824019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of manufacturers' specifications for 44 types of heat and moisture exchanging filters.
    Dellamonica J; Boisseau N; Goubaux B; Raucoules-Aimé M
    Br J Anaesth; 2004 Oct; 93(4):532-9. PubMed ID: 15298877
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of filters with small infants.
    Whitelock DE; de Beer DA
    Respir Care Clin N Am; 2006 Jun; 12(2):307-20. PubMed ID: 16828697
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Humidification in intensive care.
    Joynt GM; Lipman J
    S Afr J Surg; 1994 Mar; 32(1):23-30. PubMed ID: 11218439
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficiency of airway heat and moisture exchangers in anesthetized humans.
    Bickler PE; Sessler DI
    Anesth Analg; 1990 Oct; 71(4):415-8. PubMed ID: 2400121
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical effects of airway humidification devices in difficult to wean patients.
    Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
    Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of breathing filters under wet conditions: a laboratory evaluation.
    Turnbull D; Fisher PC; Mills GH; Morgan-Hughes NJ
    Br J Anaesth; 2005 May; 94(5):675-82. PubMed ID: 15734786
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Airway humidification practices in Chilean intensive care units].
    Retamal J; Castillo J; Bugedo G; Bruhn A
    Rev Med Chil; 2012 Nov; 140(11):1425-30. PubMed ID: 23677188
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Principles of prevention of pneumonia associated with the use of artificial ventilation of the lungs in resuscitation and intensive care units].
    Eremenko AA; Ziuliaeva TP; Bozh'eva LV; Bogomolova NS; Oreshkina TD; Bol'shakov LV; Kuslieva EV
    Anesteziol Reanimatol; 2001; (2):16-9. PubMed ID: 11494892
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Association between implementation of CDC recommendations and ventilator-associated pneumonia at selected US hospitals.
    Manangan LP; Banerjee SN; Jarvis WR
    Am J Infect Control; 2000 Jun; 28(3):222-7. PubMed ID: 10840341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bacterial filters in respiratory circuits: an unnecessary cost?
    Lorente L; Lecuona M; Málaga J; Revert C; Mora ML; Sierra A
    Crit Care Med; 2003 Aug; 31(8):2126-30. PubMed ID: 12973169
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.