223 related articles for article (PubMed ID: 11514470)
21. [Cardiac pacemaker dysfunction secondary to outside interference: a review].
Grobéty M; Perret F; Schlaepfer J; Kappenberger L
Schweiz Med Wochenschr; 1996 Apr; 126(17):723-33. PubMed ID: 8668984
[TBL] [Abstract][Full Text] [Related]
22. Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators.
Wolber T; Ryf S; Binggeli C; Holzmeister J; Brunckhorst C; Luechinger R; Duru F
Heart Rhythm; 2007 Jan; 4(1):1-4. PubMed ID: 17198980
[TBL] [Abstract][Full Text] [Related]
23. Use of mobile phones in ICU--why not ban?
Yeolekar ME; Sharma A
J Assoc Physicians India; 2004 Apr; 52():311-3. PubMed ID: 15636335
[TBL] [Abstract][Full Text] [Related]
24. Interference with an implantable defibrillator by an electronic antitheft-surveillance device.
Santucci PA; Haw J; Trohman RG; Pinski SL
N Engl J Med; 1998 Nov; 339(19):1371-4. PubMed ID: 9801398
[No Abstract] [Full Text] [Related]
25. Are patients with cardiac implants protected against electromagnetic interference in daily life and occupational environment?
Napp A; Stunder D; Maytin M; Kraus T; Marx N; Driessen S
Eur Heart J; 2015 Jul; 36(28):1798-804. PubMed ID: 25908772
[TBL] [Abstract][Full Text] [Related]
26. [Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: a systematic review].
Martins RP; Baruteau AE; Treguer F; Césari O; Carsin-Nicol B; Langella B; Leclercq C; Daubert JC; Mabo P
Ann Cardiol Angeiol (Paris); 2010 Aug; 59(4):221-8. PubMed ID: 19962691
[TBL] [Abstract][Full Text] [Related]
27. [Radiotherapy in patients with a pacemaker or an implantable cardioverter defibrillator].
Zaremba T; Thøgersen AM; Jakobsen AR; Hjortshøj SP; Eschen O; Riahi S
Ugeskr Laeger; 2011 Sep; 173(36):2195-7. PubMed ID: 21893003
[TBL] [Abstract][Full Text] [Related]
28. Electrosurgery in patients with pacemakers/implanted cardioverter defibrillators.
Dawes JC; Mahabir RC; Hillier K; Cassidy M; de Haas W; Gillis AM
Ann Plast Surg; 2006 Jul; 57(1):33-6. PubMed ID: 16799305
[TBL] [Abstract][Full Text] [Related]
29. Electromagnetic interference and implanted cardiac devices: the nonmedical environment (part I).
Misiri J; Kusumoto F; Goldschlager N
Clin Cardiol; 2012 May; 35(5):276-80. PubMed ID: 22539305
[TBL] [Abstract][Full Text] [Related]
30. Electronic article surveillance (EAS) systems.
Zipes DP
Pacing Clin Electrophysiol; 1999 Mar; 22(3):543-4. PubMed ID: 10192872
[No Abstract] [Full Text] [Related]
31. [Magnets, pacemaker and defibrillator: fatal attraction?].
Bergamin C; Graf D
Rev Med Suisse; 2015 May; 11(476):1185-91. PubMed ID: 26182637
[TBL] [Abstract][Full Text] [Related]
32. Electromagnetic interference and implanted cardiac devices: the medical environment (part II).
Misiri J; Kusumoto F; Goldschlager N
Clin Cardiol; 2012 Jun; 35(6):321-8. PubMed ID: 22539263
[TBL] [Abstract][Full Text] [Related]
33. Investigation of hyfrecators and their in vitro interference with implantable cardiac devices.
Weyer C; Siegle RJ; Eng GG
Dermatol Surg; 2012 Nov; 38(11):1843-8. PubMed ID: 22889152
[TBL] [Abstract][Full Text] [Related]
34. Risk of electromagnetic interference induced by dental equipment on cardiac implantable electrical devices.
Miranda-Rius J; Lahor-Soler E; Brunet-Llobet L; Sabaté de la Cruz X
Eur J Oral Sci; 2016 Dec; 124(6):559-565. PubMed ID: 27748971
[TBL] [Abstract][Full Text] [Related]
35. Irradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience.
Ferrara T; Baiotto B; Malinverni G; Caria N; Garibaldi E; Barboni G; Stasi M; Gabriele P
Tumori; 2010; 96(1):76-83. PubMed ID: 20437862
[TBL] [Abstract][Full Text] [Related]
36. Implantable pulse generators (pacemakers) and electrodes: safety in the magnetic resonance imaging scanner environment.
Bhachu DS; Kanal E
J Magn Reson Imaging; 2000 Jul; 12(1):201-4. PubMed ID: 10931581
[TBL] [Abstract][Full Text] [Related]
37. Implantable rhythm devices and electromagnetic interference: myth or reality?
Dyrda K; Khairy P
Expert Rev Cardiovasc Ther; 2008 Jul; 6(6):823-32. PubMed ID: 18570620
[TBL] [Abstract][Full Text] [Related]
38. Do Electric Cars Interfere With Pacemakers and Defibrillators?
Ann Intern Med; 2018 Sep; 169(5):. PubMed ID: 29710315
[No Abstract] [Full Text] [Related]
39. Magnet decoration, beautiful but potentially dangerous for patients with implantable pacemakers or defibrillators.
Li H
Heart Rhythm; 2007 Jan; 4(1):5-6. PubMed ID: 17198981
[No Abstract] [Full Text] [Related]
40. Are microwave ovens, cell phones, and other such devices dangerous to people with pacemakers?
Johns Hopkins Med Lett Health After 50; 2000 May; 12(3):8. PubMed ID: 10798288
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]