These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 11523035)

  • 1. Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: a comparative in vivo study.
    Kraft CN; Burian B; Perlick L; Wimmer MA; Wallny T; Schmitt O; Diedrich O
    J Biomed Mater Res; 2001 Dec; 57(3):404-12. PubMed ID: 11523035
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel.
    Kraft CN; Diedrich O; Burian B; Schmitt O; Wimmer MA
    J Bone Joint Surg Br; 2003 Jan; 85(1):133-41. PubMed ID: 12585592
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Striated muscle microvascular response to silver implants: A comparative in vivo study with titanium and stainless steel.
    Kraft CN; Hansis M; Arens S; Menger MD; Vollmar B
    J Biomed Mater Res; 2000 Feb; 49(2):192-9. PubMed ID: 10571905
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Striated muscle microvascular response to implants with sol-gel calcium phosphate coating. A comparative in vivo study].
    Kraft CN; Weber W; Burian B; Zander D; Wallny T; Schmitt O; Diedrich O
    Z Orthop Ihre Grenzgeb; 2002; 140(6):672-80. PubMed ID: 12476392
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb.
    Kraft CN; Burian B; Diedrich O; Gessmann J; Wimmer MA; Pennekamp PH
    J Biomed Mater Res A; 2005 Oct; 75(1):31-40. PubMed ID: 16078208
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb.
    Pennekamp PH; Gessmann J; Diedrich O; Burian B; Wimmer MA; Frauchiger VM; Kraft CN
    J Orthop Res; 2006 Mar; 24(3):531-40. PubMed ID: 16463365
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys.
    Pennekamp PH; Wimmer MA; Eschbach L; Burian B; Koch P; Kraft CN
    J Mater Sci Mater Med; 2007 Oct; 18(10):2053-60. PubMed ID: 17558479
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications.
    Talha M; Behera CK; Sinha OP
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):3563-75. PubMed ID: 23910251
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of local cooling on microvascular hemodynamics and leukocyte adhesion in the striated muscle of hamsters.
    Thorlacius H; Vollmar B; Westermann S; Törkvist L; Menger MD
    J Trauma; 1998 Oct; 45(4):715-9. PubMed ID: 9783610
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation.
    Kraft CN; Burian B; Diedrich O; Wimmer MA
    J Mater Sci Mater Med; 2001; 12(10-12):1057-62. PubMed ID: 15348365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tailoring Surface Hydrophilicity Property for Biomedical 316L and 304 Stainless Steels: A Special Perspective on Studying Osteoconductivity and Biocompatibility.
    Peng C; Izawa T; Zhu L; Kuroda K; Okido M
    ACS Appl Mater Interfaces; 2019 Dec; 11(49):45489-45497. PubMed ID: 31714730
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
    Serhan H; Slivka M; Albert T; Kwak SD
    Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires.
    Kim H; Johnson JW
    Angle Orthod; 1999 Feb; 69(1):39-44. PubMed ID: 10022183
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of dextran on microvascular disturbances and tissue injury following ischemia/reperfusion in striated muscle.
    Steinbauer M; Harris AG; Leiderer R; Abels C; Messmer K
    Shock; 1998 May; 9(5):345-51. PubMed ID: 9617884
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Surface cooling inhibits tumor necrosis factor-alpha-induced microvascular perfusion failure, leukocyte adhesion, and apoptosis in the striated muscle.
    Westermann S; Vollmar B; Thorlacius H; Menger MD
    Surgery; 1999 Nov; 126(5):881-9. PubMed ID: 10568188
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Striated muscle microvascular response to zymosan-induced generalized inflammation in awake hamsters.
    Geeraedts LM; Vollmar B; Menger MD; Geisweid A; Jansen MJ; Goris RJ; Messmer K
    Shock; 1998 Aug; 10(2):103-9. PubMed ID: 9721976
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of Diaspirin Crosslinked Hemoglobin (DCLHb) on microcirculation and local tissue pO2 of striated skin muscle following resuscitation from hemorrhagic shock.
    Hungerer S; Nolte D; Botzlar A; Messmer K
    Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(5):455-71. PubMed ID: 16893810
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Soft tissue response to a new austenitic stainless steel with a negligible nickel content.
    Tschon M; Fini M; Giavaresi G; Borsari V; Lenger H; Bernauer J; Chiesa R; Cigada A; Chiusoli L; Giardino R
    Int J Artif Organs; 2005 Oct; 28(10):1003-11. PubMed ID: 16288438
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative in vitro biocompatibility of nickel-titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation.
    Assad M; Lemieux N; Rivard CH; Yahia LH
    Biomed Mater Eng; 1999; 9(1):1-12. PubMed ID: 10436848
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.