These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
121 related articles for article (PubMed ID: 11523243)
1. Accuracy and consistency of respiratory inductive plethysmography for overnight tidal volume measurement. Zhang J; Ruch EW; Bloch KE J Tongji Med Univ; 2001; 21(1):35-7, 58. PubMed ID: 11523243 [TBL] [Abstract][Full Text] [Related]
2. Accuracy of respiratory inductive plethysmography during wakefulness and sleep in patients with obstructive sleep apnea. Cantineau JP; Escourrou P; Sartene R; Gaultier C; Goldman M Chest; 1992 Oct; 102(4):1145-51. PubMed ID: 1395758 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of respiratory inductive plethysmograph in measuring tidal volume during sleep. Whyte KF; Gugger M; Gould GA; Molloy J; Wraith PK; Douglas NJ J Appl Physiol (1985); 1991 Nov; 71(5):1866-71. PubMed ID: 1761484 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of respiratory inductive plethysmography in controlled ventilation: measurement of tidal volume and PEEP-induced changes of end-expiratory lung volume. Neumann P; Zinserling J; Haase C; Sydow M; Burchardi H Chest; 1998 Feb; 113(2):443-51. PubMed ID: 9498965 [TBL] [Abstract][Full Text] [Related]
5. Tidal volume measurements in newborns using respiratory inductive plethysmography. Adams JA; Zabaleta IA; Stroh D; Johnson P; Sackner MA Am Rev Respir Dis; 1993 Sep; 148(3):585-88. PubMed ID: 8368627 [TBL] [Abstract][Full Text] [Related]
6. Respiratory inductive plethysmography as a method for measuring ventilatory parameters in conscious, non-restrained dogs. Murphy DJ; Renninger JP; Schramek D J Pharmacol Toxicol Methods; 2010; 62(1):47-53. PubMed ID: 20435149 [TBL] [Abstract][Full Text] [Related]
7. Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs. Warren RH; Fewell JE; Alderson SH J Dev Physiol; 1989 Dec; 12(6):347-52. PubMed ID: 2640229 [TBL] [Abstract][Full Text] [Related]
8. Importance of breath size in calibrating the respiratory inductive plethysmograph. Millman RP; Chung DC; Shore ET Chest; 1986 Jun; 89(6):840-5. PubMed ID: 3709249 [TBL] [Abstract][Full Text] [Related]
9. Comparison of supine and prone noninvasive measurements of breathing patterns in fullterm newborns. Adams JA; Zabaleta IA; Sackner MA Pediatr Pulmonol; 1994 Jul; 18(1):8-12. PubMed ID: 7970915 [TBL] [Abstract][Full Text] [Related]
10. Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs. Warren RH; Fewell JE; Alderson SH Chest; 1988 Aug; 94(2):325-8. PubMed ID: 3396411 [TBL] [Abstract][Full Text] [Related]
11. Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration. Brüllmann G; Fritsch K; Thurnheer R; Bloch KE Respiration; 2010; 79(2):112-20. PubMed ID: 19365103 [TBL] [Abstract][Full Text] [Related]
12. Detection of inspiratory flow limitation during sleep by computer assisted respiratory inductive plethysmography. Kaplan V; Zhang JN; Russi EW; Bloch KE Eur Respir J; 2000 Mar; 15(3):570-8. PubMed ID: 10759455 [TBL] [Abstract][Full Text] [Related]
13. Validation of respiratory inductive plethysmography in patients with pulmonary disease. Tobin MJ; Jenouri G; Lind B; Watson H; Schneider A; Sackner MA Chest; 1983 Apr; 83(4):615-20. PubMed ID: 6831949 [TBL] [Abstract][Full Text] [Related]
14. Estimates of ventilation from inductance plethysmography in sleeping asthmatic patients. Ballard RD; Kelly PL; Martin RJ Chest; 1988 Jan; 93(1):128-33. PubMed ID: 3335143 [TBL] [Abstract][Full Text] [Related]
15. Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography. Grossman P; Spoerle M; Wilhelm FH Biomed Sci Instrum; 2006; 42():193-8. PubMed ID: 16817607 [TBL] [Abstract][Full Text] [Related]
17. Measurement of ventilation in children using the respiratory inductive plethysmograph. Tabachnik E; Muller N; Toye B; Levison H J Pediatr; 1981 Dec; 99(6):895-9. PubMed ID: 7310582 [TBL] [Abstract][Full Text] [Related]
18. Positional vs nonpositional obstructive sleep apnea patients: anthropomorphic, nocturnal polysomnographic, and multiple sleep latency test data. Oksenberg A; Silverberg DS; Arons E; Radwan H Chest; 1997 Sep; 112(3):629-39. PubMed ID: 9315794 [TBL] [Abstract][Full Text] [Related]
19. Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmography, The CHIME Study Group. Collaborative Home Infant Monitoring Evaluation. Brooks LJ; DiFiore JM; Martin RJ Pediatr Pulmonol; 1997 Jun; 23(6):429-33. PubMed ID: 9220525 [TBL] [Abstract][Full Text] [Related]
20. Quantitative validation of the suprasternal pressure signal to assess respiratory effort during sleep. Cerina L; Papini GB; Fonseca P; Overeem S; van Dijk JP; van Meulen F; Vullings R Physiol Meas; 2024 May; 45(5):. PubMed ID: 38749433 [No Abstract] [Full Text] [Related] [Next] [New Search]