These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 11523610)

  • 1. Far-field R wave oversensing in a dual chamber arrhythmia management device: predisposing factors and practical implications.
    Weretka S; Becker R; Hilbel T; Karle C; Osswald BR; Kuebler W; Schoels W
    Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1240-6. PubMed ID: 11523610
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system.
    Schoels W; Swerdlow CD; Jung W; Stein KM; Seidl K; Haffajee CJ;
    J Cardiovasc Electrophysiol; 2001 May; 12(5):521-8. PubMed ID: 11386511
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator. Advantages and complications. The Ventak AV II DR investigators.
    Sticherling C; Schaumann A; Klingenheben T; Hohnloser SH
    Europace; 1999 Apr; 1(2):96-102. PubMed ID: 11233190
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrical proarrhythmia: induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator.
    Wolpert C; Jung W; Scholl C; Spehl S; Cyran J; Lüderitz B
    J Cardiovasc Electrophysiol; 1998 Aug; 9(8):859-63. PubMed ID: 9727665
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.
    Dijkman B; Wellens HJ
    J Cardiovasc Electrophysiol; 2000 Oct; 11(10):1105-15. PubMed ID: 11059974
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Far-field R wave oversensing in dual chamber pacemakers designed for atrial arrhythmia management: effect of pacing site and lead tip to ring distance.
    Inama G; Santini M; Padeletti L; Boriani G; Botto G; Capucci A; Gulizia M; Ricci R; Rizzon P; Ferri F; Miraglia F; Raneri R; Grammatico A
    Pacing Clin Electrophysiol; 2004 Sep; 27(9):1221-30. PubMed ID: 15461712
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New ICD-technologies: first clinical experience with dual-chamber sensing for differentiation of supraventricular tachyarrhythmias.
    Osswald S; Cron TA; Sterns L; Alt E; Stotts L; Coenen M
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 2):292-5. PubMed ID: 9474691
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ventricular oversensing: a study of 101 patients implanted with dual chamber defibrillators and two different lead systems.
    Weretka S; Michaelsen J; Becker R; Karle CA; Voss F; Hilbel T; Osswald BR; Bahner ML; Senges JC; Kuebler W; Schoels W
    Pacing Clin Electrophysiol; 2003 Jan; 26(1 Pt 1):65-70. PubMed ID: 12685142
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators.
    Theuns D; Klootwijk AP; Kimman GP; Szili-Török T; Roelandt JR; Jordaens L
    Europace; 2001 Jul; 3(3):181-6. PubMed ID: 11467458
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experience with a dual chamber implantable defibrillator.
    Kühlkamp V; Wilkoff BL; Brown AB; Volosin KJ; Hügl BJ; Stafford W; Cameron DA
    Pacing Clin Electrophysiol; 2002 Jul; 25(7):1041-8. PubMed ID: 12164444
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing.
    Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P
    Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prevalence of sensing abnormalities in dual chamber implantable cardioverter defibrillators.
    Saeed M; Jin A; Pontone G; Higgins S; Gold M; Harari D; Nunley S; Link MS; Homoud MK; Estes NA; Wang PJ;
    Ann Noninvasive Electrocardiol; 2003 Jul; 8(3):219-26. PubMed ID: 14510657
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture.
    Gunderson BD; Swerdlow CD; Wilcox JM; Hayman JE; Ousdigian KT; Ellenbogen KA
    Heart Rhythm; 2010 May; 7(5):626-33. PubMed ID: 20184977
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.
    Dijkman B; Wellens HJ
    J Cardiovasc Electrophysiol; 2000 Nov; 11(11):1196-205. PubMed ID: 11083239
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-Term Stability and Clinical Utility of Amplified Atrial Electrograms in a Single-Lead ICD System with Floating Atrial Electrodes.
    Worden NE; Alqasrawi M; Mazur A
    Pacing Clin Electrophysiol; 2016 Dec; 39(12):1327-1334. PubMed ID: 27778352
    [TBL] [Abstract][Full Text] [Related]  

  • 16. T-wave oversensing in implantable cardiac defibrillators is due to technical failure of device sensing.
    Gilliam FR
    J Cardiovasc Electrophysiol; 2006 May; 17(5):553-6. PubMed ID: 16684033
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of atrial tachyarrhythmia detection in implantable devices with arrhythmia therapies.
    Purerfellner H; Gillis AM; Holbrook R; Hettrick DA
    Pacing Clin Electrophysiol; 2004 Jul; 27(7):983-92. PubMed ID: 15271020
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.
    Swerdlow CD; Schsls W; Dijkman B; Jung W; Sheth NV; Olson WH; Gunderson BD
    Circulation; 2000 Feb; 101(8):878-85. PubMed ID: 10694527
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias.
    Occhetta E; Bortnik M; Magnani A; Francalacci G; Marino P
    Europace; 2006 Oct; 8(10):863-9. PubMed ID: 16916859
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectrum of issues detected by an ICD diagnostic alert that utilizes far-field electrograms: Clinical implications.
    Koneru JN; Kaszala K; Bordachar P; Shehata M; Swerdlow C; Ellenbogen KA
    Heart Rhythm; 2015 May; 12(5):957-67. PubMed ID: 25640632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.