BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 11529077)

  • 1. A diffusive sampling device for the determination of formaldehyde in air using N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH) as reagent.
    Büldt A; Lindahl R; Levin JO; Karst U
    J Environ Monit; 1999 Feb; 1(1):39-43. PubMed ID: 11529077
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Field sampling and determination of formaldehyde in indoor air with solid-phase microextraction and on-fiber derivatization.
    Koziel JA; Noah J; Pawliszyn J
    Environ Sci Technol; 2001 Apr; 35(7):1481-6. PubMed ID: 11348090
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An automatic monitor of formaldehyde in air by a monitoring tape method.
    Nakano N; Nagashima K
    J Environ Monit; 1999 Jun; 1(3):255-8. PubMed ID: 11529112
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diffusive sampling of methyl isocyanate using 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ) as derivatizing agent.
    Henneken H; Lindahl R; Ostin A; Vogel M; Levin JO; Karst U
    J Environ Monit; 2003 Feb; 5(1):100-5. PubMed ID: 12619763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a diffusive sampling method for determination of methyl isocyanate in air.
    von Zweigbergk P; Lindahl R; Ostin A; Ekman J; Levin JO
    J Environ Monit; 2002 Oct; 4(5):663-6. PubMed ID: 12400911
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Portable formaldehyde monitoring device using porous glass sensor and its applications in indoor air quality studies.
    Maruo YY; Nakamura J
    Anal Chim Acta; 2011 Sep; 702(2):247-53. PubMed ID: 21839205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Colorimetric determination of formaldehyde in air using a hanging drop of chromotropic acid.
    Pretto A; Milani MR; Cardoso AA
    J Environ Monit; 2000 Dec; 2(6):566-70. PubMed ID: 11296742
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monitoring of parts-per-billion levels of formaldehyde using a diffusive sampler.
    Levin JO; Lindahl R; Andersson K
    JAPCA; 1989 Jan; 39(1):44-7. PubMed ID: 2709076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of airborne formaldehyde by active sampling on 3-methyl-2-benzothiazolinone hydrazone hydrochloride-coated glass fibre filters.
    Chan WH; Shuang S; Choi MM
    Analyst; 2001 May; 126(5):720-3. PubMed ID: 11394322
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Portable sick house syndrome gas monitoring system based on novel colorimetric reagents for the highly selective and sensitive detection of formaldehyde.
    Suzuki Y; Nakano N; Suzuki K
    Environ Sci Technol; 2003 Dec; 37(24):5695-700. PubMed ID: 14717182
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Development and performance evaluation for a solid phase adsorption gas sampler of formaldehyde in indoor air].
    Yao XY; Wang W; Chen YL; Wang Y; Qi Q
    Wei Sheng Yan Jiu; 2005 Jul; 34(4):410-2. PubMed ID: 16229260
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Method for multiple gaseous pollutants monitoring by passive sampler].
    Fu B
    Wei Sheng Yan Jiu; 2002 Oct; 31(5):390-3. PubMed ID: 12572367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A diffusive sampling device for simultaneous determination of ozone and carbonyls.
    Uchiyama S; Inaba Y; Kunugita N
    Anal Chim Acta; 2011 Apr; 691(1-2):119-24. PubMed ID: 21458640
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of a detector tube method in formaldehyde measurement.
    Azuma M; Endo Y; Miyazaki T; Hikita Y; Ikeda H; Moriya Y; Hara I; Araki S
    Ind Health; 2003 Oct; 41(4):306-12. PubMed ID: 14620665
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of acrylic acid in air by using diffusion denuder tubes combined with HPLC technique.
    Zanella R; Schilling M; Klockow D
    J Environ Monit; 1999 Oct; 1(5):441-3. PubMed ID: 11529161
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Badge-type diffusive sampler using 3-methyl-2-benzothiazolinone hydrazone for measuring formaldehyde in indoor air.
    Yim B; Jung E
    Anal Sci; 2006 Jul; 22(7):993-7. PubMed ID: 16837752
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of acetaldehyde in tobacco smoke using N-methyl-4-hydrazino-7-nitrobenzofurazan and liquid chromatography/mass spectrometry.
    Zurek G; Büldt A; Karst U
    Fresenius J Anal Chem; 2000 Feb; 366(4):396-9. PubMed ID: 11220327
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sensitive indoor air monitoring of formaldehyde and other carbonyl compounds using the 2,4-dinitrophenylhydrazine method.
    Sandner F; Dott W; Hollender J
    Int J Hyg Environ Health; 2001 Mar; 203(3):275-9. PubMed ID: 11279824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Indoor and outdoor formaldehyde concentrations in homes in residential areas in Greater Cairo.
    Khoder MI; Shakour AA; Farag SA; Abdel Hameed AA
    J Environ Monit; 2000 Apr; 2(2):123-6. PubMed ID: 11253030
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of formaldehyde in indoor air by a liquid sorbent technique.
    Georghiou PE; Winsor L; Sliwinski JF; Shirtliffe CJ
    IARC Sci Publ; 1993; (109):245-50. PubMed ID: 8514354
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.