These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

83 related articles for article (PubMed ID: 11547938)

  • 1. A new method to catheterize a femoral artery in mice using a nylon suture as a 'guide wire'.
    Fukui S; Nawshiro H; Wada K; Shima K; Hallenbeck JM
    Neurol Res; 2001 Sep; 23(6):655-6. PubMed ID: 11547938
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of 10-0 polypropylene and 10-0 nylon sutures in rat arterial anastomosis.
    Chen LE; Seaber AV; Urbaniak JR
    Microsurgery; 1993; 14(5):328-33. PubMed ID: 8332053
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel rat middle cerebral artery occlusion model: Trans-femoral artery approach combined with preservation of the external carotid artery.
    Shimamura N; Matsuda N; Katayama K; Ohkuma H
    J Neurosci Methods; 2009 Nov; 184(2):195-8. PubMed ID: 19666053
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new simple method of converting a retrograde femoral access to an antegrade catheterization.
    Ysa A; Lobato M; Gómez R; Arruabarrena A; Metcalfe M; Fonseca JL
    J Vasc Surg; 2014 Sep; 60(3):792-5. PubMed ID: 24797552
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Vascular sutures using polyglycolic acid in growing arteries. Experimental study].
    Hernández González N; González Alvarez P; González Espinosa C; González Hermoso F; Díaz Flores L
    An Esp Pediatr; 1984 May; 20(8):800-6. PubMed ID: 6089630
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Practical microsurgery.
    Daniel RK; Entin MA
    Clin Plast Surg; 1976 Jan; 3(1):39-47. PubMed ID: 765049
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Groin infection caused by a percutaneous femoral artery closure device: report of a case.
    Yamamoto N; Koyano K; Azuma M; Ochiai H; Kashiwabara T
    Surg Today; 2003; 33(10):801-4. PubMed ID: 14513335
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rapid neurorrhaphy with titanium clips.
    Park JW; Lee KS; Kim SK; Park JH; Hong JS; Oh KJ
    Microsurgery; 2002; 22(8):386-90. PubMed ID: 12497577
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling focal cerebral ischemia in vivo.
    Jackman K; Kunz A; Iadecola C
    Methods Mol Biol; 2011; 793():195-209. PubMed ID: 21913102
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Directional needle for antegrade guide wire placement with vertical arterial puncture.
    Hawkins JS; Coryell LW; Miles SG; Giovannetti MJ; Siragusa RJ; Hawkins IF
    Radiology; 1988 Jul; 168(1):271-2. PubMed ID: 3380973
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The short-term effects of Dexon and nylon sutures in experimental microvascular surgery--a quantitative comparison.
    Cook AF; Azar CA; Dinner MI
    J Hand Surg Am; 1983 May; 8(3):299-301. PubMed ID: 6308097
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Use of the OUTBACK Re-entry Catheter for recanalization of a joint-transversing extensive occlusion of the femoral and popliteal arteries].
    Lichtenberg M; Hailer B
    Herz; 2011 Feb; 36(1):24-7. PubMed ID: 20938624
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Easy technique to overcome the undesirable catheterization of the profunda femoral artery during antegrade femoral access.
    Ysa A; Bustabad MR; Arruabarrena A; Peña M; Fonseca JL
    Ann Vasc Surg; 2010 Aug; 24(6):841-3. PubMed ID: 20413262
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Closure of the subclavian artery puncture site with a percutaneous suture device after removal of an arterial pacemaker lead.
    Meyhoefer J; Lehmann H; Minden HH; Butter C
    Europace; 2006 Dec; 8(12):1070-2. PubMed ID: 17098776
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental evaluation of microsurgical techniques in small artery anastomoses.
    Urbaniak JR; Soucacos PN; Adelaar RS; Bright DS; Whitehurst LA
    Orthop Clin North Am; 1977 Apr; 8(2):249-63. PubMed ID: 331181
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microanastomotic response to needle and suture size.
    Lourie GM; Seaber AV; Urbaniak JR
    J Reconstr Microsurg; 1984 Oct; 1(2):135-8. PubMed ID: 6544349
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of silicon-coated nylon suture to plain nylon suture in the rat middle cerebral artery occlusion model.
    Shimamura N; Matchett G; Tsubokawa T; Ohkuma H; Zhang J
    J Neurosci Methods; 2006 Sep; 156(1-2):161-5. PubMed ID: 16569436
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Superficial femoral artery catheterisation with two parallel guidewires after femoris profunda artery cannulation in antegrade percutaneous femoral access.
    Zenunaj G; Traina L; Gasbarro V
    Ann R Coll Surg Engl; 2021 Oct; 103(9):701-704. PubMed ID: 34414802
    [No Abstract]   [Full Text] [Related]  

  • 19. In vivo evaluation of nylon suture material by the scanning electron microscope.
    Gregorius FK; Rand RW
    Surg Gynecol Obstet; 1976 Sep; 143(3):429-32. PubMed ID: 785639
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Histopathology of the arterial wall after animal experiment microsurgical operations].
    Tilgner A
    Z Exp Chir Transplant Kunstliche Organe; 1986; 19(2):100-12. PubMed ID: 3727655
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.