These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
211 related articles for article (PubMed ID: 1154826)
21. Mass spectrometry/gas chromatography-mass spectrometry approach for rapid screening/quantitative determination of perchloroethylene in air. Richter P; Zúñiga C; Calderón K; Carrasco R J Chromatogr A; 2006 Jan; 1102(1-2):232-7. PubMed ID: 16257001 [TBL] [Abstract][Full Text] [Related]
22. Determination of benzene, toluene, ethylbenzene, xylenes in water at sub-ng l-1 levels by solid-phase microextraction coupled to cryo-trap gas chromatography-mass spectrometry. Lee MR; Chang CM; Dou J Chemosphere; 2007 Nov; 69(9):1381-7. PubMed ID: 17582460 [TBL] [Abstract][Full Text] [Related]
23. Measurement of organic vapors at sub-TLV concentrations using fast gas chromatography. Mouradian RF; Levine SP; Sacks RD; Spence MW Am Ind Hyg Assoc J; 1990 Feb; 51(2):90-5. PubMed ID: 2305678 [TBL] [Abstract][Full Text] [Related]
24. The combined use of thermal desorption and selected ion flow tube mass spectrometry for the quantification of xylene and toluene in air. Ross BM; Vermeulen N Rapid Commun Mass Spectrom; 2007; 21(22):3608-12. PubMed ID: 17939161 [TBL] [Abstract][Full Text] [Related]
25. [Gas chromatography measurement of benzene/toluene in atmospheric air using absorptive samples and thermal desorption]. Hanika G Z Gesamte Hyg; 1988 Jan; 34(1):46-8. PubMed ID: 3369186 [No Abstract] [Full Text] [Related]
26. [Separation and determination, using a gas-chromatographic method, of vinyl acetate, methyl acetate and methyl alcohol in industrial environments]. Bianchi A; Modesti I; Muccioli G; Sergi C Ann Ist Super Sanita; 1977; 13(1-2):239-44. PubMed ID: 603121 [TBL] [Abstract][Full Text] [Related]
27. Headspace-mass spectrometry determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers in soil samples using chemometrics. Esteve-Turrillas FA; Armenta S; Garrigues S; Pastor A; de la Guardia M Anal Chim Acta; 2007 Mar; 587(1):89-96. PubMed ID: 17386758 [TBL] [Abstract][Full Text] [Related]
28. Passive sampling of glycol ethers and their acetates in indoor air. Plaisance H; Desmettres P; Leonardis T; Pennequin-Cardinal A; Locoge N; Galloo JC J Environ Monit; 2008 Apr; 10(4):517-26. PubMed ID: 18385873 [TBL] [Abstract][Full Text] [Related]
29. Benzene, toluene and xylene (BTX) pollution in ambient air: a case study. Deole S; Phadke KM; Kumar A J Environ Sci Eng; 2004 Jan; 46(1):15-20. PubMed ID: 16649588 [TBL] [Abstract][Full Text] [Related]
30. Green determination of the presence of volatile organic compounds in vehicle repair shops through passive sampling. Sanjuán-Herráez D; Lliso I; Pastor A; de la Guardia M Talanta; 2012 Aug; 98():40-8. PubMed ID: 22939126 [TBL] [Abstract][Full Text] [Related]
31. A simple method for the extraction of volatile organic compounds contained in air samples from adsorbent materials by solid phase microextraction and their analysis by gas chromatography/mass spectrometry. Saba A; Raffaelli A; Pucci S; Salvadori P Rapid Commun Mass Spectrom; 1999; 13(19):1899-902. PubMed ID: 10487935 [TBL] [Abstract][Full Text] [Related]
32. Performance testing of the NIOSH charcoal tube technique for the determination of air concentrations of organic vapors. Saalwaechter AT; McCammon CS; Roper P; Carlberg KS Am Ind Hyg Assoc J; 1977 Sep; 38(9):476-86. PubMed ID: 906963 [TBL] [Abstract][Full Text] [Related]
33. [The gas chromatographic analysis of environmental objects by inputting large volumes of vapor-gas mixtures into the capillary column]. Tarasov SN; Kruchinin SN; Dan'ko SA Gig Sanit; 1999; (5):73-5. PubMed ID: 10560204 [No Abstract] [Full Text] [Related]
34. [Determination of morpholine in the presence of isopropyl alcohol, toluene and xylene in the workshop air by means of gas chromatography]. Bianchi A; Muccioli G Ann Ist Super Sanita; 1978; 14(3):441-5. PubMed ID: 755395 [No Abstract] [Full Text] [Related]
35. Analysis of volatile organic compounds (VOCs) in sediments using in situ SPME sampling. Bravo-Linares CM; Mudge SM J Environ Monit; 2007 May; 9(5):411-8. PubMed ID: 17492085 [TBL] [Abstract][Full Text] [Related]
36. [Method of sampling condensed trace contaminants in human exhaled air for subsequent gas-chromatographic analysis]. Sotnikov EE Kosm Biol Aviakosm Med; 1975; 9(2):73-5. PubMed ID: 235672 [No Abstract] [Full Text] [Related]
37. [Analysis of thinner components using the Curie-point pyrolyzer-gas chromatographic method in the tissues of a victim fatally poisoned]. Iwasaki Y; Miyazaki T; Yashiki M; Kojima T Nihon Hoigaku Zasshi; 1992 Aug; 46(4):271-5. PubMed ID: 1405020 [TBL] [Abstract][Full Text] [Related]
38. Study of the effect of sample pressure on in situ BTEX chromatographs. Trigueros CR; Miñarro MD; Duperón EG; Marzal FJ; Ferradás EG Environ Monit Assess; 2016 Dec; 188(12):665. PubMed ID: 27838876 [TBL] [Abstract][Full Text] [Related]
39. [Determining the levels of toluene, benzene and xylene in hand washings from the skin of workers by a method of vapor-phase chromatographic analysis]. Chernitsyna MA Gig Sanit; 1989 Jan; (1):38-41. PubMed ID: 2721993 [No Abstract] [Full Text] [Related]
40. Determination of benzene at trace levels in air by a novel method based on solid-phase microextraction gas chromatography/mass spectrometry. Saba A; Cuzzola A; Raffaelli A; Pucci S; Salvadori P Rapid Commun Mass Spectrom; 2001; 15(24):2404-8. PubMed ID: 11746910 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]