These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
153 related articles for article (PubMed ID: 11548948)
1. Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations. Bohm TD; Mourtada FA; Das RK Med Phys; 2001 Aug; 28(8):1770-5. PubMed ID: 11548948 [TBL] [Abstract][Full Text] [Related]
2. Dosimetry characterization of 32P catheter-based vascular brachytherapy source wire. Mourtada FA; Soares CG; Seltzer SM; Lott SH Med Phys; 2000 Aug; 27(8):1770-6. PubMed ID: 10984223 [TBL] [Abstract][Full Text] [Related]
3. Measurements and Monte Carlo calculations to determine the absolute detector response of radiochromic film for brachytherapy dosimetry. Bohm TD; Pearson DW; Das RK Med Phys; 2001 Feb; 28(2):142-6. PubMed ID: 11243336 [TBL] [Abstract][Full Text] [Related]
4. Self-absorption correction for 32P, 198Au and 188Re stents: dose point kernel calculations versus Monte Carlo. Reynaert N; Häfeli UO Med Phys; 2001 Sep; 28(9):1883-97. PubMed ID: 11585219 [TBL] [Abstract][Full Text] [Related]
5. Dose distributions for 90Y intravascular brachytherapy sources used with balloon catheters. Piessens M; Reynaert N; Potempa J; Thierens H; Wijns W; Verbeke L Med Phys; 2002 Jul; 29(7):1562-71. PubMed ID: 12148739 [TBL] [Abstract][Full Text] [Related]
6. Monte Carlo characterization of a 32P source for intravascular brachytherapy. Wang R; Li XA Med Phys; 2001 Aug; 28(8):1776-85. PubMed ID: 11548949 [TBL] [Abstract][Full Text] [Related]
7. Determination of surface dose rate of indigenous (32)P patch brachytherapy source by experimental and Monte Carlo methods. Kumar S; Srinivasan P; Sharma SD; Saxena SK; Bakshi AK; Dash A; Babu DA; Sharma DN Appl Radiat Isot; 2015 Sep; 103():120-7. PubMed ID: 26086681 [TBL] [Abstract][Full Text] [Related]
8. Monte Carlo dose calculations using MCNP4C and EGSnrc/BEAMnrc codes to study the energy dependence of the radiochromic film response to beta-emitting sources. Pacilio M; Aragno D; Rauco R; D'Onofrio S; Pressello MC; Bianciardi L; Santini E Phys Med Biol; 2007 Jul; 52(13):3931-48. PubMed ID: 17664586 [TBL] [Abstract][Full Text] [Related]
9. Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements. Sureka CS; Sunny CS; Subbaiah KV; Aruna P; Ganesan S Phys Med Biol; 2007 Jan; 52(2):525-37. PubMed ID: 17202631 [TBL] [Abstract][Full Text] [Related]
10. Dosimetry characterization of 32P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4. Torres J; Buades MJ; Almansa JF; Guerrero R; Lallena AM Med Phys; 2004 Feb; 31(2):296-304. PubMed ID: 15000615 [TBL] [Abstract][Full Text] [Related]
11. 32P brachytherapy conformal source model RIC-100 for high-dose-rate treatment of superficial disease: Monte Carlo calculations, diode measurements, and clinical implementation. Cohen GN; Munro JJ; Kirov A; Losasso T; Yamada Y; Williamson M; Dauer LT; Zaider M Int J Radiat Oncol Biol Phys; 2014 Mar; 88(3):746-52. PubMed ID: 24411623 [TBL] [Abstract][Full Text] [Related]
12. Experimental dosimetry of a 32P catheter-based endovascular brachytherapy source. Piermattei A; Fidanzio A; Perrone F; Azario L; Grimaldi L; Viola P; Capote R Phys Med Biol; 2003 Aug; 48(15):2283-96. PubMed ID: 12953898 [TBL] [Abstract][Full Text] [Related]
13. Dosimetry characterization of a 32P source wire used for intravascular brachytherapy with automated stepping. Mourtada F; Soares CG; Seltzer SM; Bergstrom PM; Fernández-Verea JM; Asenjo J; Lott SH Med Phys; 2003 May; 30(5):959-71. PubMed ID: 12773005 [TBL] [Abstract][Full Text] [Related]
14. Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy. Reynaert N; Verhaegen F; Taeymans Y; Van Eijkeren M; Thierens H Med Phys; 1999 Aug; 26(8):1484-91. PubMed ID: 10501047 [TBL] [Abstract][Full Text] [Related]
15. Prospects for quantitative two-dimensional radiochromic film dosimetry for low dose-rate brachytherapy sources. Le Y; Ali I; Dempsey JF; Williamson JF Med Phys; 2006 Dec; 33(12):4622-34. PubMed ID: 17278815 [TBL] [Abstract][Full Text] [Related]
16. IVBTMC, a Monte Carlo dose calculation tool for intravascular brachytherapy. Chibani O; Li XA Med Phys; 2003 Jan; 30(1):44-51. PubMed ID: 12557978 [TBL] [Abstract][Full Text] [Related]
17. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE. Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828 [TBL] [Abstract][Full Text] [Related]
18. Dosimetric evaluation of the Fletcher-Williamson ovoid for pulsed-dose-rate brachytherapy: a Monte Carlo study. Price MJ; Horton JL; Gifford KA; Eifel PJ; Jhingran A; Lawyer AA; Berner PA; Mourtada F Phys Med Biol; 2005 Nov; 50(21):5075-87. PubMed ID: 16237242 [TBL] [Abstract][Full Text] [Related]
19. High beta and electron dose from 192Ir: implications for "gamma" intravascular brachytherapy. Patel NS; Chiu-Tsao ST; Ho Y; Duckworth T; Shih JA; Tsao HS; Quon H; Harrison LB Int J Radiat Oncol Biol Phys; 2002 Nov; 54(3):972-80. PubMed ID: 12377352 [TBL] [Abstract][Full Text] [Related]
20. Dose effects of stents in intravascular brachytherapy for in-stent restenosis: a Monte Carlo calculation. Li XA Int J Radiat Oncol Biol Phys; 2003 Mar; 55(3):842-8. PubMed ID: 12573772 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]