524 related articles for article (PubMed ID: 11550234)
1. Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.
Zhang X; Ugurbil K; Chen W
Magn Reson Med; 2001 Sep; 46(3):443-50. PubMed ID: 11550234
[TBL] [Abstract][Full Text] [Related]
2. Microstrip Transmission Line RF Coil for a PET/MRI Insert.
Akram MSH; Obata T; Yamaya T
Magn Reson Med Sci; 2020 May; 19(2):147-153. PubMed ID: 31776297
[TBL] [Abstract][Full Text] [Related]
3. A microstrip transmission line volume coil for human head MR imaging at 4T.
Zhang X; Ugurbil K; Chen W
J Magn Reson; 2003 Apr; 161(2):242-51. PubMed ID: 12713976
[TBL] [Abstract][Full Text] [Related]
4. A volume microstrip RF coil for MRI microscopy.
Jasiński K; Młynarczyk A; Latta P; Volotovskyy V; Węglarz WP; Tomanek B
Magn Reson Imaging; 2012 Jan; 30(1):70-7. PubMed ID: 22055746
[TBL] [Abstract][Full Text] [Related]
5. An inverted-microstrip resonator for human head proton MR imaging at 7 tesla.
Zhang X; Ugurbil K; Sainati R; Chen W
IEEE Trans Biomed Eng; 2005 Mar; 52(3):495-504. PubMed ID: 15759580
[TBL] [Abstract][Full Text] [Related]
6. Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils.
Paulus DH; Braun H; Aklan B; Quick HH
Med Phys; 2012 Jul; 39(7):4306-15. PubMed ID: 22830764
[TBL] [Abstract][Full Text] [Related]
7. B1 field, SAR, and SNR comparisons for birdcage, TEM, and microstrip coils at 7T.
Wang C; Shen GX
J Magn Reson Imaging; 2006 Aug; 24(2):439-43. PubMed ID: 16786582
[TBL] [Abstract][Full Text] [Related]
8. Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications.
Alfonsetti M; Clementi V; Iotti S; Placidi G; Lodi R; Barbiroli B; Sotgiu A; Alecci M
MAGMA; 2005 May; 18(2):69-75. PubMed ID: 15625584
[TBL] [Abstract][Full Text] [Related]
9. Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.
Rutledge O; Kwak T; Cao P; Zhang X
J Magn Reson; 2016 Jun; 267():15-21. PubMed ID: 27078089
[TBL] [Abstract][Full Text] [Related]
10. Common-mode differential-mode (CMDM) method for double-nuclear MR signal excitation and reception at ultrahigh fields.
Pang Y; Zhang X; Xie Z; Wang C; Vigneron DB
IEEE Trans Med Imaging; 2011 Nov; 30(11):1965-73. PubMed ID: 21693414
[TBL] [Abstract][Full Text] [Related]
11. Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.
Zhao Y; Zhao T; Raval SB; Krishnamurthy N; Zheng H; Harris CT; Handler WB; Chronik BA; Ibrahim TS
Magn Reson Med; 2015 Nov; 74(5):1461-9. PubMed ID: 25367703
[TBL] [Abstract][Full Text] [Related]
12. Higher-order harmonic transmission-line RF coil design for MR applications.
Zhang X; Zhu XH; Chen W
Magn Reson Med; 2005 May; 53(5):1234-9. PubMed ID: 15844152
[TBL] [Abstract][Full Text] [Related]
13. Radiation induced current in the RF coils of integrated linac-MR systems: the effect of buildup and magnetic field.
Burke B; Ghila A; Fallone BG; Rathee S
Med Phys; 2012 Aug; 39(8):5004-14. PubMed ID: 22894426
[TBL] [Abstract][Full Text] [Related]
14. Tilt optimized flip uniformity (TOFU) RF pulse for uniform image contrast at low specific absorption rate levels in combination with a surface breast coil at 7 Tesla.
van Kalleveen IM; Boer VO; Luijten PR; Klomp DW
Magn Reson Med; 2015 Aug; 74(2):482-8. PubMed ID: 25160960
[TBL] [Abstract][Full Text] [Related]
15. Development of a 7 T RF coil system for breast imaging.
Kim J; Santini T; Bae KT; Krishnamurthy N; Zhao Y; Zhao T; Ibrahim TS
NMR Biomed; 2017 Jan; 30(1):. PubMed ID: 27859861
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of Common RF Coil Setups for MR Imaging at Ultrahigh Magnetic Field: A Numerical Study.
Lu J; Pang Y; Wang C; Wu B; Vigneron DB; Zhang X
Int Symp Appl Sci Biomed Commun Technol; 2011; 2011():. PubMed ID: 28966929
[TBL] [Abstract][Full Text] [Related]
17. A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications.
Barberi EA; Gati JS; Rutt BK; Menon RS
Magn Reson Med; 2000 Feb; 43(2):284-9. PubMed ID: 10680693
[TBL] [Abstract][Full Text] [Related]
18. Development and evaluation of a multichannel endorectal RF coil for prostate MRI at 7T in combination with an external surface array.
Ertürk MA; Tian J; Van de Moortele PF; Adriany G; Metzger GJ
J Magn Reson Imaging; 2016 Jun; 43(6):1279-87. PubMed ID: 26584144
[TBL] [Abstract][Full Text] [Related]
19. Radiofrequency shielding of surface coils at 4.0 T.
Ong KC; Wen H; Chesnick AS; Duewell S; Jaffer FA; Balaban RS
J Magn Reson Imaging; 1995; 5(6):773-7. PubMed ID: 8748501
[TBL] [Abstract][Full Text] [Related]
20. Linear microstrip surface coil for MR imaging of the rat spinal cord at 4.7 T.
Burian M; Hájek M
MAGMA; 2004 Dec; 17(3-6):359-62. PubMed ID: 15580372
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]