These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 1155173)

  • 21. Experiences with the microsphere technique for measurement of intra-renal blood flow distribution.
    Källskog O; Lindbom LO; Pinter G; Ulfendahl HR; Wolgast M
    Bibl Anat; 1977; (15 Pt 1):66-70. PubMed ID: 597221
    [No Abstract]   [Full Text] [Related]  

  • 22. Heterogeneity in regulation of glomerular function.
    Ericson AC; Sjöquist M; Ulfendahl HR
    Acta Physiol Scand; 1982 Feb; 114(2):203-9. PubMed ID: 7136754
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of kidney tubule obstruction on glomerular function in rats.
    Tanner GA
    Am J Physiol; 1979 Nov; 237(5):F379-85. PubMed ID: 495753
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Maturational changes in glomerular perfusion rate and glomerular filtration rate in lambs.
    Aperia A; Broberger O; Herin P
    Pediatr Res; 1974 Aug; 8(8):758-65. PubMed ID: 4844526
    [No Abstract]   [Full Text] [Related]  

  • 25. Intrarenal distribution of renal blood flow in the rat.
    Rosivall L; Pósch E; Simon G; László E; Hársing L
    Acta Physiol Acad Sci Hung; 1979; 53(4):389-97. PubMed ID: 317553
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Glomerular morphometry in the Munich-Wistar rat.
    Shea SM; Raskova J
    Microcirc Endothelium Lymphatics; 1985; 2(5):499-515. PubMed ID: 3836353
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of methods of measuring glomerular and nutrient blood flow in rat kidneys.
    Yarger WE; Boyd MA; Schrader NW
    Am J Physiol; 1978 Nov; 235(5):H592-600. PubMed ID: 727280
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Xenon-133 washout for measuring intrarenal blood flow in the micropuncture rat.
    Kinney MJ; Quinones J; Rudich S; DiScala V
    Am J Physiol; 1974 Sep; 227(3):657-64. PubMed ID: 4416918
    [No Abstract]   [Full Text] [Related]  

  • 29. Left ventricular cannulation for microsphere estimation of rabbit renal blood flow.
    Bhattacharya J; Beilin LJ
    Am J Physiol; 1980 May; 238(5):H736-9. PubMed ID: 7377368
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Renal blood flow distribution at varying perfusion pressure in the alloperfused dog kidney.
    Heller J; Horácek V; Kasalický J
    Pflugers Arch; 1979 Oct; 382(1):91-8. PubMed ID: 574942
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Microsphere size and determination of intrarenal blood flow distribution in the rat.
    Mimran A; Casellas D
    Pflugers Arch; 1979 Nov; 382(3):233-40. PubMed ID: 575413
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Radioactive microsphere distribution and single glomerular blood flow in the normal rabbit kidney.
    Bankir L; Farman N; Grünfeld JP; De la Tour EH; Funck-Brentano JL
    Pflugers Arch; 1973 Aug; 342(2):111-23. PubMed ID: 4795632
    [No Abstract]   [Full Text] [Related]  

  • 33. Effect of hemorrhage on single glomerular blood-flow as related to central hemodynamics and acid-base balance.
    Hellberg M; Källskog O; Wolgast M
    Acta Anaesthesiol Scand; 1973; 17(1):27-36. PubMed ID: 4720338
    [No Abstract]   [Full Text] [Related]  

  • 34. An attempt to measure glomerular plasma flow by the cationic dyes alcian blue and ruthenium red.
    Lavik OJ; Aukland K
    Ren Physiol; 1985; 8(3):136-9. PubMed ID: 2410960
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simultaneous measurement of cardiac output and its distribution with microspheres in the rat.
    McDevitt DG; Nies AS
    Cardiovasc Res; 1976 Jul; 10(4):494-8. PubMed ID: 947337
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measurement of glomerular blood flow in rabbits and rats: erroneous findings with 15-micron microspheres.
    Bankir L; Tan MM; Grünfeld JP
    Kidney Int; 1979 Feb; 15(2):126-33. PubMed ID: 513480
    [No Abstract]   [Full Text] [Related]  

  • 37. A comparison of three radionuclide techniques for measuring blood flow to rat extremities.
    Fisher SM; Aspin N; Hobbs BB; Greyson ND
    Invest Radiol; 1977; 12(2):164-8. PubMed ID: 852951
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Renal blood flow, afferent vascular resistance, and estimated glomerular capillary pressure in the nonexposed rat kidney.
    Ishikawa I; Hollenberg NK
    Circ Res; 1977 Jul; 41(1):67-73. PubMed ID: 862145
    [No Abstract]   [Full Text] [Related]  

  • 39. Lack of effect of barbiturate and ketamine anesthesia on renal blood flow in chronically instrumented rats prepared for micropuncture.
    Cupples WA; Veress AT; Sonnenberg H
    Can J Physiol Pharmacol; 1982 Feb; 60(2):204-7. PubMed ID: 7083069
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Renal blood flow and function in the rabbit after surgical trauma. III. Effects of temporary occlusion of renal artery.
    Lyrdal F; Olin T
    Scand J Urol Nephrol; 1975; 9(2):151-60. PubMed ID: 1145145
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.