These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 11555470)

  • 1. A multicentre evaluation of a new filtration protocol for leucocyte depletion of high-haematocrit red blood cells collected by an automated blood collection system.
    Soli M; Blanco L; Riggert J; Martínez-Clavel A; Lucas C; Lunghi M; Belloni M; Wolf C; van Waeg G; Antoon M
    Vox Sang; 2001; 81(2):108-12. PubMed ID: 11555470
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of dosed red blood cell units collected with Gambro BCT--TRIMA.
    Valbonesi M; Bruni R; Florio G; Zanella A; van Waeg G
    Transfus Apher Sci; 2001 Feb; 24(1):65-70. PubMed ID: 11515612
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro quality of red blood cells (RBCs) collected by multicomponent apheresis compared to manually collected RBCs during 49 days of storage.
    Picker SM; Radojska SM; Gathof BS
    Transfusion; 2007 Apr; 47(4):687-96. PubMed ID: 17381628
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of haemoglobin, haematocrit, haemolysis, residual protein content and leucocytes in 345 red blood cell concentrates used for the treatment of patients with β-thalassaemia.
    Mancini R; Marinelli L; Mirante N; Gallo A; Matteocci A; Terlizzi F; Palange M; Fioravanti D; Donnini L; Pierelli L
    Blood Transfus; 2012 Jan; 10(1):39-44. PubMed ID: 22153690
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Leukocyte removal in a closed system of human red-cell concentrates: a technic coupled with the automated extraction of the buffy coat using a sterile connector from a filtration kit].
    Angué M; Chatelain P; Richaud P; Guignier F; Domy M
    Rev Fr Transfus Hemobiol; 1989 Sep; 32(4):265-75. PubMed ID: 2818771
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a concurrent multicomponent collection system for the collection and storage of WBC-reduced RBC apheresis concentrates.
    Moog R; Franck V; Pierce JA; Müller N
    Transfusion; 2001 Sep; 41(9):1159-64. PubMed ID: 11552075
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of Cobe Trima for the collection of blood components with particular reference to the in vitro characteristics of the red cell and platelet concentrates and the clinical responses to transfusion.
    Murphy MF; Seghatchian J; Krailadsiri P; Howell C; Verjee S
    Transfus Sci; 2000; 22(1-2):39-43. PubMed ID: 10771377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A national quality assessment scheme for counting residual leucocytes in unfixed leucodepleted products: the effect of standardisation and 48 hour storage.
    Krailadsiri P; Seghatchian J; Rigsby P; Bukasa A; Bashir S
    Transfus Apher Sci; 2002 Feb; 26(1):73-81. PubMed ID: 11931380
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated collection of blood components: their storage and transfusion.
    Rock G; Moltzan C; Alharbi A; Giulivi A; Palmer D; Bormanis J
    Transfus Med; 2003 Aug; 13(4):219-25. PubMed ID: 12880392
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a new, integral, whole blood filter (RS2000) system for prestorage leucodepletion of SAG-M red cells.
    Rider JR; Moore G; Payrat JM; Chan D; Morse C; Standen GR; Pamphilon DH
    Br J Haematol; 1996 Jul; 94(1):184-90. PubMed ID: 8757533
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preparation of white cell-reduced red cells by filtration: comparison of a bedside filter and two blood bank filter systems.
    Sprogøe-Jakobsen U; Saetre AM; Georgsen J
    Transfusion; 1995 May; 35(5):421-6. PubMed ID: 7740614
    [TBL] [Abstract][Full Text] [Related]  

  • 12. WBC reduction in RBC concentrates by prestorage filtration: multicenter experience.
    Yomtovian R; Gernsheimer T; Assmann SF; Mohandas K; Lee TH; Kalish LA; Busch MP;
    Transfusion; 2001 Aug; 41(8):1030-6. PubMed ID: 11493735
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility and rate of leucocyte depletion with a single leucocyte depletion filter during massive transfusion.
    Rieger A; Saefkow M; Hass I; Spies C; Eyrich K
    Infusionsther Transfusionsmed; 1995 Dec; 22(6):355-9. PubMed ID: 8589596
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Concurrent collection of in-line filtered platelets and red blood cells by apheresis.
    Moog R; Bartsch R; Müller N
    Ann Hematol; 2002 Jun; 81(6):322-5. PubMed ID: 12107562
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Efficacy of 2 different leukocyte filters for erythrocyte concentrates].
    Barth A; Passerini M; Oppliger R; Spycher M; Nydegger U
    Schweiz Med Wochenschr; 1993 Jun; 123(22):1160-4. PubMed ID: 8322051
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo and in vitro characteristics of double units of RBCs collected by apheresis with a single in-line WBC-reduction filter.
    Bandarenko N; Rose M; Kowalsky RJ; Baston RK; Brecher ME; Elfath MD; Whitley P; Heminway M; Holme S
    Transfusion; 2001 Nov; 41(11):1373-7. PubMed ID: 11724980
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated collection of double red blood cell units with a variable-volume separation chamber.
    Aubuchon JP; Dumont LJ; Herschel L; Roger J; Beddard RL; Taylor HL; Whitley PH; Sawyer SL; Graminske S; Martinson K; Dora R; Heldke S; Adamson J; Rose LE
    Transfusion; 2008 Jan; 48(1):147-52. PubMed ID: 17894787
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A new separation protocol (DRBCP-F) for automated blood component donation with the MCS 3p cell separator for collection of leukocyte depleted erythrocyte concentrates and plasma].
    Zeiler T; Kretschmer V
    Beitr Infusionsther Transfusionsmed; 1997; 34():118-22. PubMed ID: 9417335
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Leucocyte filtration of salvaged blood during cardiac surgery: effect on red blood cell function in concentrated blood compared with diluted blood.
    Gu YJ; de Vries AJ; Hagenaars JA; van Oeveren W
    Eur J Cardiothorac Surg; 2009 Nov; 36(5):877-82. PubMed ID: 19608429
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prestorage WBC filtration of RBC units with soft-shell filters: filtration performance and impact on RBCs during storage for 42 days.
    Müller-Steinhardt M; Hennig H; Kirchner H; Schlenke P
    Transfusion; 2002 Feb; 42(2):153-8. PubMed ID: 11896328
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.