These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 1156077)

  • 1. [ Exsanguination, extreme hemodilution and autologous retransfusion in cardiopulmonary bypass].
    Argüero R; Escalante G; Ochoa E; Soria G; Cuellar L; Solis G
    Arch Invest Med (Mex); 1975; 6(1):41-54. PubMed ID: 1156077
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retrograde autologous prime with shortened bypass circuits decreases blood transfusion in high-risk coronary artery surgery patients.
    Zelinka ES; Ryan P; McDonald J; Larson J
    J Extra Corpor Technol; 2004 Dec; 36(4):343-7. PubMed ID: 15679275
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Retrograde autologous priming for cardiopulmonary bypass: a safe and effective means of decreasing hemodilution and transfusion requirements.
    Rosengart TK; DeBois W; O'Hara M; Helm R; Gomez M; Lang SJ; Altorki N; Ko W; Hartman GS; Isom OW; Krieger KH
    J Thorac Cardiovasc Surg; 1998 Feb; 115(2):426-38; discussion 438-9. PubMed ID: 9475538
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Feasibility of autologous intraoperative blood collection and retransfusion in small children with complex congenital heart defects undergoing cardiopulmonary bypass.
    Kaiser A; Miller K; Tian G; Moore RH; Guzzetta NA
    Paediatr Anaesth; 2018 Sep; 28(9):795-802. PubMed ID: 30079485
    [TBL] [Abstract][Full Text] [Related]  

  • 5. PRECiSe (priming reduced extracorporeal circulation setup): results of a safety study.
    Beholz S; Kessler M; Konertz WF
    Heart Surg Forum; 2003; 6(5):311-5. PubMed ID: 14721800
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retransfusion of pericardial blood does not trigger systemic coagulation during cardiopulmonary bypass.
    van den Goor JM; Nieuwland R; Rutten PM; Tijssen JG; Hau C; Sturk A; Eijsman L; de Mol BA
    Eur J Cardiothorac Surg; 2007 Jun; 31(6):1029-36. PubMed ID: 17350849
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transfusion-free cardiac surgery with cardiopulmonary bypass in a 2.2-kg neonate.
    Hübler M; Boettcher W; Koster A; Redlin M; Stiller B; Lange P; Hetzer R
    J Card Surg; 2005; 20(2):180-2. PubMed ID: 15725146
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Open heart surgery in children of Jehovah's Witnesses: extreme hemodilution on cardiopulmonary bypass.
    Stein JI; Gombotz H; Rigler B; Metzler H; Suppan C; Beitzke A
    Pediatr Cardiol; 1991 Jul; 12(3):170-4. PubMed ID: 1876516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retrograde autologous priming of the cardiopulmonary bypass circuit reduces blood transfusion after coronary artery surgery.
    Balachandran S; Cross MH; Karthikeyan S; Mulpur A; Hansbro SD; Hobson P
    Ann Thorac Surg; 2002 Jun; 73(6):1912-8. PubMed ID: 12078790
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Open heart surgery for small children without homologous blood transfusion by using remote pump head system.
    Ando M; Takahashi Y; Suzuki N
    Ann Thorac Surg; 2004 Nov; 78(5):1717-22. PubMed ID: 15511461
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prospective randomized study comparing volume-standardized modified and conventional ultrafiltration in pediatric cardiac surgery.
    Thompson LD; McElhinney DB; Findlay P; Miller-Hance W; Chen MJ; Minami M; Petrossian E; Parry AJ; Reddy VM; Hanley FL
    J Thorac Cardiovasc Surg; 2001 Aug; 122(2):220-8. PubMed ID: 11479493
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single center experience with a low volume priming cardiopulmonary bypass circuit for preventing blood transfusion in infants and small children.
    Kotani Y; Honjo O; Nakakura M; Fujii Y; Ugaki S; Oshima Y; Yoshizumi K; Kasahara S; Sano S
    ASAIO J; 2009; 55(3):296-9. PubMed ID: 19282750
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of hemodilution and fresh autologous blood in open-heart surgery.
    Lawson NW; Ochsner JL; Mills NL; Leonard GL
    Anesth Analg; 1974; 53(5):672-83. PubMed ID: 4472399
    [No Abstract]   [Full Text] [Related]  

  • 14. [Clinical studies on extracorporeal circulation with increased hemodilution. II. Oxygen utilization with special reference to optimal flow rate].
    Ban T; Tatsuta N; Asai N; Miki S; Maho L; Sato M
    Thoraxchir Vask Chir; 1973 Feb; 21(1):42-50. PubMed ID: 4144271
    [No Abstract]   [Full Text] [Related]  

  • 15. [Open heart surgery without the use of homologous blood in infants and young children: effectiveness of the intraoperative autologous blood donation from arterial monitoring line].
    Kurisu K; Yonenaga K; Miyamoto K; Furusho N; Nishimura K
    Kyobu Geka; 1999 Jun; 52(6):438-41; discussion 441-4. PubMed ID: 10380468
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Small, smaller, smallest. Steps towards bloodless neonatal and infant cardiopulmonary bypass.
    Golab HD; Bogers JJ
    Perfusion; 2009 Jul; 24(4):239-42. PubMed ID: 19843622
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Randomized trial of hematocrit 25% versus 35% during hypothermic cardiopulmonary bypass in infant heart surgery.
    Newburger JW; Jonas RA; Soul J; Kussman BD; Bellinger DC; Laussen PC; Robertson R; Mayer JE; del Nido PJ; Bacha EA; Forbess JM; Pigula F; Roth SJ; Visconti KJ; du Plessis AJ; Farrell DM; McGrath E; Rappaport LA; Wypij D
    J Thorac Cardiovasc Surg; 2008 Feb; 135(2):347-54, 354.e1-4. PubMed ID: 18242267
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pediatric cardiac surgery without homologous blood transfusion, using a miniaturized bypass system in infants with lower body weight.
    Miyaji K; Kohira S; Miyamoto T; Nakashima K; Sato H; Ohara K; Yoshimura H
    J Thorac Cardiovasc Surg; 2007 Aug; 134(2):284-9. PubMed ID: 17662763
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The effect of hemodilution on the indices of aerobic metabolism and water metabolism in children with congenital heart defects operated on under artificial circulation].
    Merunko AA; Shipulin VM; Korbut AA; Pak VA; Podoksenov IuK
    Anesteziol Reanimatol; 1998; (1):38-41. PubMed ID: 9553260
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of miniaturization of cardiopulmonary bypass circuit on blood transfusion requirement in neonatal open-heart surgery.
    Kotani Y; Honjo O; Nakakura M; Ugaki S; Kawabata T; Kuroko Y; Osaki S; Yoshizumi K; Kasahara S; Ishino K; Sano S
    ASAIO J; 2007; 53(6):662-5. PubMed ID: 18043142
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.