These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
42. Anesthesia breathing circuits protected by the DAR Barrierbac S breathing filter have a low bacterial contamination rate. Vézina DP; Trépanier CA; Lessard MR; Gourdeau M; Tremblay C Can J Anaesth; 2001 Sep; 48(8):748-54. PubMed ID: 11546714 [TBL] [Abstract][Full Text] [Related]
43. Incompatibility of disposable heated-wire breathing circuits and heated-wire humidifiers. Health Devices; 1993; 22(5-6):300-1. PubMed ID: 8253592 [No Abstract] [Full Text] [Related]
44. The effect of flow on the filtration performance of paediatric breathing system filters. Wilkes AR; Malan CA; Hall JE Anaesthesia; 2008 Jan; 63(1):71-6. PubMed ID: 18086073 [TBL] [Abstract][Full Text] [Related]
45. Humidification during anesthesia. Carson KD Respir Care Clin N Am; 1998 Jun; 4(2):281-99. PubMed ID: 9648187 [TBL] [Abstract][Full Text] [Related]
46. The effect of volatile anaesthetic agents on the filtration performance of paediatric breathing system filters. Froom SR; Cann C; Wilkes AR; Gildersleve C; Hall JE Anaesthesia; 2008 Jan; 63(1):77-81. PubMed ID: 18086074 [TBL] [Abstract][Full Text] [Related]
48. [Prevention of infections transmitted by CPAP and noninvasive ventilation]. Benhamou D; Cuvelier A; Muir JF Rev Pneumol Clin; 2001 Apr; 57(2):73-8. PubMed ID: 11353913 [TBL] [Abstract][Full Text] [Related]
49. Hidden hazards and dangers associated with the use of HME/filters in breathing circuits. Their effect on toxic metabolite production, pulse oximetry and airway resistance. Lawes EG Br J Anaesth; 2003 Aug; 91(2):249-64. PubMed ID: 12878625 [No Abstract] [Full Text] [Related]
50. [Are humidity filters necessary in the inspired air in the breathing circuit? A new in vivo method of measuring humidity in the air breathed]. Kohler P; Rimek A; Albrecht M; Frankenberger H; Mertins W; van Ackern K Anasthesiol Intensivmed Notfallmed Schmerzther; 1992 May; 27(3):149-55. PubMed ID: 1617027 [TBL] [Abstract][Full Text] [Related]
51. The influence of breathing system filters on paediatric capnography. Hardman JG; Mahajan RP; Curran J Paediatr Anaesth; 1999; 9(1):35-8. PubMed ID: 10712713 [TBL] [Abstract][Full Text] [Related]
52. [Evaluation of 2 bacterial filters connected to the respirator for the prevention of nosocomial pulmonary infection]. Coustets B; Moatti N; Andrieu P; Decun JF; Mazerolles M Agressologie; 1990; 31(8 Spec No):560-2. PubMed ID: 2089987 [TBL] [Abstract][Full Text] [Related]
53. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia. Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654 [TBL] [Abstract][Full Text] [Related]
54. Breathing system filters for paediatric practice. Bennett NR; Bingham R Anaesthesia; 2007 Feb; 62(2):192-3; author reply 193. PubMed ID: 17223817 [No Abstract] [Full Text] [Related]
55. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed once a week. Paluch B Am J Respir Crit Care Med; 2001 Nov; 164(10 Pt 1):1999-2000. PubMed ID: 11734460 [No Abstract] [Full Text] [Related]
56. Bilateral tension pneumothorax due to a defective anesthesia breathing circuit filter. Smith CE; Otworth JR; Kaluszyk P J Clin Anesth; 1991; 3(3):229-34. PubMed ID: 1878237 [TBL] [Abstract][Full Text] [Related]
58. The bacterial and viral filtration performance of breathing system filters. Wilkes AR; Benbough JE; Speight SE; Harmer M Anaesthesia; 2000 May; 55(5):458-65. PubMed ID: 10792138 [TBL] [Abstract][Full Text] [Related]
59. [A trial comparing artificial noses and heat exchangers during assisted ventilation using tracheotomy at home. CARDIF. The Committee of the Organization of Respiratory Assistance of the Ile-de-France]. Antoun F; Guyen JN Rev Mal Respir; 1993; 10(5):437-44. PubMed ID: 8256030 [TBL] [Abstract][Full Text] [Related]