These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 11570746)

  • 1. Doubly rotated contoured quartz resonators.
    Sinha BK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Sep; 48(5):1162-80. PubMed ID: 11570746
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental verification of stress compensation in the SBTC-cut.
    Valdois M; Sinha BK; Boy JJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 1989; 36(6):643-51. PubMed ID: 18290245
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of thickness modes of contoured doubly rotated, quartz resonators.
    EerNisse EP
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Sep; 48(5):1351-61. PubMed ID: 11570760
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An analysis of the thickness vibration of an unelectroded doubly-rotated quartz circular plate.
    Xie L; Wang S; Zhang C; Wang J
    J Acoust Soc Am; 2018 Aug; 144(2):814. PubMed ID: 30180667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Variational formulation of the Stevens-Tiersten equation and application in the analysis of rectangular trapped-energy quartz resonators.
    Shi J; Fan C; Zhao M; Yang J
    J Acoust Soc Am; 2014 Jan; 135(1):175-81. PubMed ID: 24437757
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An analysis of thickness-shear vibrations of doubly-rotated quartz crystal plates with the corrected first-order Mindlin plate equations.
    Du J; Wang W; Chen G; Wu R; Huang D; Ma T; Wang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Nov; 60(11):2371-80. PubMed ID: 24158292
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A dual-mode thickness-shear quartz pressure sensor.
    Besson RJ; Boy JJ; Glotin B; Jinzaki Y; Sinha B; Valdois M
    IEEE Trans Ultrason Ferroelectr Freq Control; 1993; 40(5):584-91. PubMed ID: 18263223
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thickness-shear modes of an elliptical, contoured AT-cut quartz resonator.
    Wang W; Wu R; Wang J; Du J; Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jun; 60(6):1192-8. PubMed ID: 25004481
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thickness-shear vibration of an AT-cut quartz resonator with a hyperbolic contour.
    Li P; Jin F; Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 May; 59(5):1006-12. PubMed ID: 22622986
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Membrane analogy of the Stevens-Tiersten equation for essentially thickness modes in plate quartz resonators.
    Zhang W; Yang Z; Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1665-8. PubMed ID: 18986957
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental measurements of the force-frequency effect of thickness-mode langasite resonators.
    Zhang H; Turner JA; Kosinski JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jul; 60(7):1475-8. PubMed ID: 25004514
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An analysis of partially electroded, contoured, quartz resonators with beveled cylindrical edges.
    Yang J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Nov; 54(11):2407-9. PubMed ID: 18051176
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stress-induced frequency shifts of degenerate thickness-shear modes in rotated Y-cut quartz resonators.
    Kosinski JA; Pastore RA; Yang J; Yang X; Turner JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Aug; 57(8):1880-3. PubMed ID: 20679018
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quartz strip resonators as a temperature sensor.
    Nosek J; Zelenka J
    Ultrasonics; 2001 Oct; 39(6):465-8. PubMed ID: 11775663
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental study on the characteristic of the NS-GT cut quartz crystal resonator oscillating in the sub-resonant frequency.
    Yamagata S; Kawashima H
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(5):1175-82. PubMed ID: 18244311
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Isochronism defect for various doubly rotated cut quartz resonators.
    Gufflet N; Bourquin R; Boy JJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Apr; 49(4):514-8. PubMed ID: 11989708
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental measurement of the frequency shifts of degenerate thickness-shear modes in a rotated Y-cut quartz resonator subject to diametrical forces.
    Bao Y; Zhang H; Kosinski JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Mar; 62(3):560-4. PubMed ID: 25768821
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the accuracy of Mindlin plate predictions for the frequency-temperature behavior of resonant modes in AT- and SC-cut quartz plates.
    Yong YK; Wang J; Imai T
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(1):1-13. PubMed ID: 18238393
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simulation of Nonlinear Resonance, Amplitude-Frequency, and Harmonic Generation Effects in SAW and BAW Devices.
    Pang X; Yong YK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Feb; 67(2):422-430. PubMed ID: 31603776
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measured properties of doubly rotated dilithium tetraborate (Li(2)B(4)BO(7)) resonators and transducers.
    Kosinski JA; Ballato A; Lu Y
    IEEE Trans Ultrason Ferroelectr Freq Control; 1993; 40(2):154-61. PubMed ID: 18263169
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.