122 related articles for article (PubMed ID: 11572124)
1. [Introduction of a new mobile C-arm/CT combination equipment (ISO-C-3D). Initial results of 3-D sectional imaging].
Rock C; Linsenmaier U; Brandl R; Kotsianos D; Wirth S; Kaltschmidt R; Euler E; Mutschler W; Pfeifer KJ
Unfallchirurg; 2001 Sep; 104(9):827-33. PubMed ID: 11572124
[TBL] [Abstract][Full Text] [Related]
2. [Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D)].
Rock C; Kotsianos D; Linsenmaier U; Fischer T; Brandl R; Vill F; Wirth S; Kaltschmidt R; Euler E; Pfeifer KJ; Reiser M
Rofo; 2002 Feb; 174(2):170-6. PubMed ID: 11898078
[TBL] [Abstract][Full Text] [Related]
3. [3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography].
Kotsianos D; Rock C; Euler E; Wirth S; Linsenmaier U; Brandl R; Mutschler W; Pfeifer KJ
Unfallchirurg; 2001 Sep; 104(9):834-8. PubMed ID: 11572125
[TBL] [Abstract][Full Text] [Related]
4. [Comparative study of the quality of C-arm based 3D imaging of the talus].
Euler E; Wirth S; Linsenmaier U; Mutschler W; Pfeifer KJ; Hebecker A
Unfallchirurg; 2001 Sep; 104(9):839-46. PubMed ID: 11572126
[TBL] [Abstract][Full Text] [Related]
5. [Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].
König B; Erdmenger U; Schröder RJ; Wienas G; Schaefer J; Pech M; Stöckle U
Unfallchirurg; 2005 May; 108(5):378-85. PubMed ID: 15856147
[TBL] [Abstract][Full Text] [Related]
6. In vitro high-resolution flat-panel computed tomographic arthrography for artificial cartilage defect detection: comparison with multidetector computed tomography.
Guggenberger R; Winklhofer S; Spiczak JV; Andreisek G; Alkadhi H
Invest Radiol; 2013 Aug; 48(8):614-21. PubMed ID: 23538888
[TBL] [Abstract][Full Text] [Related]
7. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care.
Stübig T; Kendoff D; Citak M; Geerling J; Khalafi A; Krettek C; Hüfner T
J Trauma; 2009 Mar; 66(3):821-30. PubMed ID: 19276760
[TBL] [Abstract][Full Text] [Related]
8. Dosimetric characterization of a cone-beam O-arm imaging system.
Zhang J; Weir V; Fajardo L; Lin J; Hsiung H; Ritenour ER
J Xray Sci Technol; 2009; 17(4):305-17. PubMed ID: 19923687
[TBL] [Abstract][Full Text] [Related]
9. [Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].
Kotsianos D; Rock C; Wirth S; Linsenmaier U; Brandl R; Fischer T; Euler E; Mutschler W; Pfeifer KJ; Reiser M
Rofo; 2002 Jan; 174(1):82-7. PubMed ID: 11793290
[TBL] [Abstract][Full Text] [Related]
10. Flat-panel CT arthrography: feasibility study and comparison to multidetector CT arthrography.
Guggenberger R; Fischer MA; Hodler J; Pfammatter T; Andreisek G
Invest Radiol; 2012 May; 47(5):312-8. PubMed ID: 22488509
[TBL] [Abstract][Full Text] [Related]
11. 3D imaging with an isocentric mobile C-arm comparison of image quality with spiral CT.
Kotsianos D; Wirth S; Fischer T; Euler E; Rock C; Linsenmaier U; Pfeifer KJ; Reiser M
Eur Radiol; 2004 Sep; 14(9):1590-5. PubMed ID: 15057563
[TBL] [Abstract][Full Text] [Related]
12. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography.
Werncke T; Sonnow L; Meyer BC; Lüpke M; Hinrichs J; Wacker FK; von Falck C
Eur J Radiol; 2017 Apr; 89():191-199. PubMed ID: 28267538
[TBL] [Abstract][Full Text] [Related]
13. C-arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers.
Guggenberger R; Morsbach F; Alkadhi H; Vich M; Pfammatter T; Hodler J; Andreisek G
Skeletal Radiol; 2013 Mar; 42(3):419-29. PubMed ID: 22926680
[TBL] [Abstract][Full Text] [Related]
14. [Comparison of quality on digital X-ray devices with 3D-capability for ENT-clinical objectives in imaging of temporal bone and paranasal sinuses].
Knörgen M; Brandt S; Kösling S
Rofo; 2012 Dec; 184(12):1153-60. PubMed ID: 23081736
[TBL] [Abstract][Full Text] [Related]
15. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems.
Du LY; Umoh J; Nikolov HN; Pollmann SI; Lee TY; Holdsworth DW
Phys Med Biol; 2007 Dec; 52(23):7087-108. PubMed ID: 18029995
[TBL] [Abstract][Full Text] [Related]
16. Intra-operative assessment of femoral antetorsion using ISO-C 3D: a cadaver study.
Hawi N; Suero EM; Liodakis E; Decker S; Krettek C; Citak M
Injury; 2014 Mar; 45(3):506-9. PubMed ID: 24268187
[TBL] [Abstract][Full Text] [Related]
17. 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D).
Heiland M; Schulze D; Adam G; Schmelzle R
Dentomaxillofac Radiol; 2003 Jan; 32(1):21-5. PubMed ID: 12820849
[TBL] [Abstract][Full Text] [Related]
18. [The isocentric C-arm. Visualization of fracture reduction and screw position in the radius].
Meier R; Geerling J; Hüfner T; Kfuri M; Krettek C
Unfallchirurg; 2011 Jul; 114(7):587-90. PubMed ID: 21710152
[TBL] [Abstract][Full Text] [Related]
19. Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.
Daly MJ; Siewerdsen JH; Moseley DJ; Jaffray DA; Irish JC
Med Phys; 2006 Oct; 33(10):3767-80. PubMed ID: 17089842
[TBL] [Abstract][Full Text] [Related]
20. Comparative evaluation of image quality from three CT simulation scanners.
McCann C; Alasti H
J Appl Clin Med Phys; 2004; 5(4):55-70. PubMed ID: 15738921
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]