These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. [Hemodynamic monitoring in the intensive care unit: pulmonary artery catheter versus PiCCO]. Gassanov N; Caglayan E; Nia A; Erdmann E; Er F Dtsch Med Wochenschr; 2011 Feb; 136(8):376-80. PubMed ID: 21332037 [TBL] [Abstract][Full Text] [Related]
4. Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients. Bendjelid K; Marx G; Kiefer N; Simon TP; Geisen M; Hoeft A; Siegenthaler N; Hofer CK Br J Anaesth; 2013 Oct; 111(4):573-9. PubMed ID: 23625132 [TBL] [Abstract][Full Text] [Related]
5. Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients. Scully CG; Gomatam S; Forrest S; Strauss DG J Clin Monit Comput; 2016 Oct; 30(5):577-86. PubMed ID: 26285740 [TBL] [Abstract][Full Text] [Related]
6. The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients. He HW; Liu DW; Long Y; Wang XT; Zhao ML; Lai XL J Clin Monit Comput; 2016 Oct; 30(5):569-75. PubMed ID: 26298710 [TBL] [Abstract][Full Text] [Related]
7. Cardiac output monitors: old and new. Dries D J Burn Care Res; 2013; 34(5):543-8. PubMed ID: 23511279 [No Abstract] [Full Text] [Related]
8. Comparison of the ability of two continuous cardiac output monitors to measure trends in cardiac output: estimated continuous cardiac output measured by modified pulse wave transit time and an arterial pulse contour-based cardiac output device. Terada T; Oiwa A; Maemura Y; Robert S; Kessoku S; Ochiai R J Clin Monit Comput; 2016 Oct; 30(5):621-7. PubMed ID: 26370094 [TBL] [Abstract][Full Text] [Related]
9. Less invasive hemodynamic monitoring in critically ill patients. Teboul JL; Saugel B; Cecconi M; De Backer D; Hofer CK; Monnet X; Perel A; Pinsky MR; Reuter DA; Rhodes A; Squara P; Vincent JL; Scheeren TW Intensive Care Med; 2016 Sep; 42(9):1350-9. PubMed ID: 27155605 [TBL] [Abstract][Full Text] [Related]
10. Unreliability of pulse contour-derived cardiac output in piglets simulating acute hemorrhagic shock and rapid volume expansion. Lee CH; Wang JY; Huang KL; Chiu HW; Fei TC; Chen TS; Chang H J Trauma; 2010 Jun; 68(6):1357-61. PubMed ID: 20539180 [TBL] [Abstract][Full Text] [Related]
11. [Continuous monitoring of cardiac output by analysis of the pulse contour]. Dos Santos P; Coste P; Bernadet P; Durrieu-Jais C; Besse P Arch Mal Coeur Vaiss; 1994 Jan; 87(1):65-74. PubMed ID: 7811153 [TBL] [Abstract][Full Text] [Related]
12. Assessment of drift of pulse contour cardiac output over varying recalibration intervals. Boyle M; Murgo M; O'Brien M Intensive Care Med; 2007 Nov; 33(11):2032-3. PubMed ID: 17607562 [No Abstract] [Full Text] [Related]
13. Accuracy of Continuous Cardiac Output Measurement With the LiDCOplus System During Intra-Aortic Counterpulsation After Cardiac Surgery. Menger J; Mora B; Skhirtladze K; Fischer A; Jan Ankersmit H; Dworschak M J Cardiothorac Vasc Anesth; 2016 Jun; 30(3):592-8. PubMed ID: 26718662 [TBL] [Abstract][Full Text] [Related]
15. Comparison of non-calibrated pulse-contour analysis with continuous thermodilution for cardiac output assessment in patients with induced hypothermia after cardiac arrest. Haenggi M; Barthelmes D; Ulmer H; Takala J; Jakob SM Resuscitation; 2011 Apr; 82(4):423-6. PubMed ID: 21292380 [TBL] [Abstract][Full Text] [Related]
16. Noninvasive cardiac output determination using applanation tonometry-derived radial artery pulse contour analysis in critically ill patients. Compton F; Wittrock M; Schaefer JH; Zidek W; Tepel M; Scholze A Anesth Analg; 2008 Jan; 106(1):171-4, table of contents. PubMed ID: 18165574 [TBL] [Abstract][Full Text] [Related]