These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 11577355)

  • 1. [Measurement of water vapour pressure in the airways of mechanically ventilated patient using different types of humidifiers].
    Rathgeber J; Betker T; Züchner K
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2001 Sep; 36(9):560-5. PubMed ID: 11577355
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The clinical and microbiological comparison of the use of heated humidifiers and heat and moisture exchanger filters with Booster in mechanically ventilated patients].
    Nadir Oziş T; Ozcan Kanat D; Oğuzülgen IK; Aydoğdu M; Hizel K; Gürsel G
    Tuberk Toraks; 2009; 57(3):259-67. PubMed ID: 19787464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
    Christiansen S; Renzing K; Hirche H; Reidemeister JC
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Resistive pressure of a condenser humidifier in mechanically ventilated patients.
    Manthous CA; Schmidt GA
    Crit Care Med; 1994 Nov; 22(11):1792-5. PubMed ID: 7956283
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Heated humidifiers. Structure and function.
    Peterson BD
    Respir Care Clin N Am; 1998 Jun; 4(2):243-59. PubMed ID: 9648185
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Air conditioning with a high-performance HME (heat and moisture exchanger)--an effective and economical alternative to active humidifiers in ventilated patients. A prospective and randomized clinical study].
    Rathgeber J; Henze D; Züchner K
    Anaesthesist; 1996 Jun; 45(6):518-25. PubMed ID: 8767565
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of a heat and moisture exchanger on tracheal climate in a cold environment.
    Zuur JK; Muller SH; Vincent A; Sinaasappel M; de Jongh FH; Hilgers FJ
    Med Eng Phys; 2009 Sep; 31(7):852-7. PubMed ID: 19481491
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate.
    Zuur JK; Muller SH; Vincent A; Sinaasappel M; de Jongh FH; Hilgers FJ
    Head Neck; 2008 Aug; 30(8):1072-82. PubMed ID: 18528903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Humidification and secretion volume in mechanically ventilated patients.
    Solomita M; Palmer LB; Daroowalla F; Liu J; Miller D; LeBlanc DS; Smaldone GC
    Respir Care; 2009 Oct; 54(10):1329-35. PubMed ID: 19796412
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Is reduction of intraoperative heat loss and management of hypothermic patients with anesthetic gas climate control advisable? Heat and humidity exchangers vs. active humidifiers ina functional lung model].
    Rathgeber J; Weyland W; Bettka T; Züchner K; Kettler D
    Anaesthesist; 1996 Sep; 45(9):807-13. PubMed ID: 8967598
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of tracheal temperature is not a reliable index of total respiratory heat loss in mechanically ventilated patients.
    Thomachot L; Viviand X; Lagier P; Dejode JM; Albanèse J; Martin C
    Crit Care; 2001; 5(1):24-30. PubMed ID: 11178222
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Humidification of respired gases in neonates and infants.
    Schiffmann H
    Respir Care Clin N Am; 2006 Jun; 12(2):321-36. PubMed ID: 16828698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The simultaneous use of a heat and moisture exchanger and a heated humidifier causes critical airway occlusion in less than 24 hours.
    Doyle A; Mariyaselvam M; Wijewardena G; English N; Gent E; Young P
    J Crit Care; 2015 Aug; 30(4):863.e1-3. PubMed ID: 25937239
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endotracheal temperature and humidity in laryngectomized patients in a warm and dry environment and the effect of a heat and moisture exchanger.
    Scheenstra RJ; Muller SH; Hilgers FJ
    Head Neck; 2011 Sep; 33(9):1285-93. PubMed ID: 21837698
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of humidifying devices on the measurement of tidal volume by mechanical ventilators.
    Fujita Y; Imanaka H; Fujino Y; Takeuchi M; Tomita T; Mashimo T; Nishimura M
    J Anesth; 2006; 20(3):166-72. PubMed ID: 16897234
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of passive humidification on respiratory heat loss in tracheotomized patients.
    Rozsasi A; Leiacker R; Fischer Y; Keck T
    Head Neck; 2006 Jul; 28(7):609-13. PubMed ID: 16475202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Heated Humidifier versus Heat-and-Moisture Exchanger During Positive Pressure Ventilation With a T-Piece Resuscitator in Rabbits.
    Bernatzky A; Galletti MF; Fuensalida SE; Mariani GL
    Respir Care; 2020 Sep; 65(9):1295-1300. PubMed ID: 32127411
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.
    Parmar V
    J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.