196 related articles for article (PubMed ID: 11578268)
1. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.
Watarida S; Shiraishi S; Nishi T; Imura M; Yamamoto Y; Hirokawa R; Fujita M
Ann Thorac Cardiovasc Surg; 2001 Aug; 7(4):246-9. PubMed ID: 11578268
[TBL] [Abstract][Full Text] [Related]
2. Manufacturing characteristics associated with strut fracture in Björk-Shiley 60 degrees Convexo-Concave heart valves.
Walker AM; Funch DP; Sulsky SI; Dreyer NA
J Heart Valve Dis; 1995 Nov; 4(6):640-8. PubMed ID: 8611980
[TBL] [Abstract][Full Text] [Related]
3. Decision guidelines for prophylactic replacement of Björk-Shiley convexo-concave heart valves: impact on clinical practice.
van Gorp MJ; Steyerberg EW; Van der Graaf Y
Circulation; 2004 May; 109(17):2092-6. PubMed ID: 15078796
[TBL] [Abstract][Full Text] [Related]
4. Three-dimensional imaging of fractures in outlet struts of Björk-Shiley convexo-concave heart valves by microcomputed tomography in vitro.
Brendzel AM; Rambod E; Jorgensen SM; Reyes DA; Chmelik MS; Ritman EL
J Heart Valve Dis; 2002 Jan; 11(1):114-20. PubMed ID: 11843496
[TBL] [Abstract][Full Text] [Related]
5. Outlet strut fracture of Björk-Shiley convexo-concave valves: can valve-manufacturing characteristics explain the risk?
Omar RZ; Morton LS; Beirne M; Blot WJ; Lawford PV; Hose R; Taylor KM
J Thorac Cardiovasc Surg; 2001 Jun; 121(6):1143-9. PubMed ID: 11385382
[TBL] [Abstract][Full Text] [Related]
6. The Björk-Shiley 70 degree convexo-concave prosthesis strut fracture problem (present state of information).
Ostermeyer J; Horstkotte D; Bennett J; Huysmans H; Lindblom D; Olin C; Orinius E; Semb G
Thorac Cardiovasc Surg; 1987 Apr; 35(2):71-7. PubMed ID: 2440138
[TBL] [Abstract][Full Text] [Related]
7. Pressure distribution near the occluders and impact forces on the outlet struts of Björk-Shiley convexo-concave valves during closing.
Chandran KB; Lee CS; Aluri S; Dellsperger KC; Schreck S; Wieting DW
J Heart Valve Dis; 1996 Mar; 5(2):199-206. PubMed ID: 8665015
[TBL] [Abstract][Full Text] [Related]
8. Outlet strut fracture of a 23-mm Björk-Shiley 70 degrees convexo-concave aortic valve.
Abad C
Cardiovasc Surg; 1993 Aug; 1(4):445-6. PubMed ID: 8076078
[TBL] [Abstract][Full Text] [Related]
9. Self-reported quality of life and health among Björk-Shiley convexo-concave prosthetic heart valve patients.
Signorello LB; Kennedy JA; Richmond RA; Sieu KL; Blot WJ; Harrison DC
J Heart Valve Dis; 2001 Mar; 10(2):210-8. PubMed ID: 11297208
[TBL] [Abstract][Full Text] [Related]
10. Twenty-five-year experience with the Björk-Shiley convexoconcave heart valve: a continuing clinical concern.
Blot WJ; Ibrahim MA; Ivey TD; Acheson DE; Brookmeyer R; Weyman A; Defauw J; Smith JK; Harrison D
Circulation; 2005 May; 111(21):2850-7. PubMed ID: 15927993
[TBL] [Abstract][Full Text] [Related]
11. Likelihood of underreporting of outlet strut fracture from examination of the Dutch Björk-Shiley CC cohort.
Kallewaard M; Algra A; Defauw J; Grobbee D; van der Graaf Y
Am J Cardiol; 1998 Sep; 82(6):768-73. PubMed ID: 9761088
[TBL] [Abstract][Full Text] [Related]
12. Single leg separation prevalence among explanted Björk-Shiley prosthetic heart valves.
Blot WJ; Signorello LB; Cohen SS; Ibrahim MA
J Heart Valve Dis; 2007 Nov; 16(6):657-61. PubMed ID: 18095516
[TBL] [Abstract][Full Text] [Related]
13. Prophylactic reoperation for strut fractures of the Björk-Shiley convexo-concave heart valve.
Schöndube FA; Althoff W; Dörge HC; Voss M; Laufer JL; Chandler JG; Messmer BJ
J Heart Valve Dis; 1994 May; 3(3):247-53. PubMed ID: 8087260
[TBL] [Abstract][Full Text] [Related]
14. Risks of fracture of Björk-Shiley 60 degree convexo-concave prosthetic heart valves: long-term cohort follow up in the UK, Netherlands and USA.
Blot WJ; Omar RZ; Kallewaard M; Morton LS; Fryzek JP; Ibrahim MA; Acheson D; Taylor KM; van der Graaf Y
J Heart Valve Dis; 2001 Mar; 10(2):202-9. PubMed ID: 11297207
[TBL] [Abstract][Full Text] [Related]
15. Mechanical failure of the Björk-Shiley valve. Incidence, clinical presentation, and management.
Lindblom D; Björk VO; Semb BK
J Thorac Cardiovasc Surg; 1986 Nov; 92(5):894-907. PubMed ID: 3773546
[TBL] [Abstract][Full Text] [Related]
16. Clinical performance of Bjork-Shiley mechanical heart valves: a perspective on outlet strut fractures in the 60 degrees and 70 degrees convexo-concave disc models.
Scully HE; Damle A; Goldman BS; Tong C; Azuma J; Mickleborough LL; Schwartz L; Baird RJ
Can J Cardiol; 1988 Oct; 4(7):386-92. PubMed ID: 3228767
[TBL] [Abstract][Full Text] [Related]
17. [Strut fracture of a convex-concave 60 degree Björk-Shiley mitral valve prosthesis 5 years after implantation--metallurgic analysis of the prosthesis strut].
Lemke B; Rathmann J; Wiebe V; Witzel U
Z Kardiol; 1991 Aug; 80(8):537-40. PubMed ID: 1950077
[TBL] [Abstract][Full Text] [Related]
18. Low frequency analysis of opening sound for detection of single leg separation of Björk-Shiley Convexo-Concave heart valves.
Durand LG; Grenier MC; Inderbitzen R; Wieting DW; Stein PD
J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S32-7. PubMed ID: 8581209
[TBL] [Abstract][Full Text] [Related]
19. Strut fracture mechanisms of the Björk-Shiley convexo-concave heart valve.
Wieting DW; Eberhardt AC; Reul H; Breznock EM; Schreck SG; Chandler JG
J Heart Valve Dis; 1999 Mar; 8(2):206-17. PubMed ID: 10224582
[TBL] [Abstract][Full Text] [Related]
20. Which manufacturing characteristics are predictors of outlet strut fracture in large sixty-degree Björk-Shiley convexo-concave mitral valves? The Björk-Shiley Study Group.
Kallewaard M; Algra A; Defauw J; van der Graaf Y
J Thorac Cardiovasc Surg; 1999 Apr; 117(4):766-75. PubMed ID: 10096973
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]