These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
180 related articles for article (PubMed ID: 11587990)
1. In vitro performance characteristics of high-frequency oscillatory ventilators. Pillow JJ; Wilkinson MH; Neil HL; Ramsden CA Am J Respir Crit Care Med; 2001 Sep; 164(6):1019-24. PubMed ID: 11587990 [TBL] [Abstract][Full Text] [Related]
2. Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome. Hager DN; Fessler HE; Kaczka DW; Shanholtz CB; Fuld MK; Simon BA; Brower RG Crit Care Med; 2007 Jun; 35(6):1522-9. PubMed ID: 17440422 [TBL] [Abstract][Full Text] [Related]
3. Volume and Pressure Delivery During Pediatric High-Frequency Oscillatory Ventilation. Wong R; Deakers T; Hotz J; Khemani RG; Ross PA; Newth CJ Pediatr Crit Care Med; 2017 Apr; 18(4):e189-e194. PubMed ID: 28212162 [TBL] [Abstract][Full Text] [Related]
4. In vitro performance comparison of the Sensormedics 3100A and B high-frequency oscillatory ventilators. Custer JW; Ahmed A; Kaczka DW; Mulreany DG; Hager DN; Simon BA; Easley RB Pediatr Crit Care Med; 2011 Jul; 12(4):e176-80. PubMed ID: 21037502 [TBL] [Abstract][Full Text] [Related]
5. Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study. Singh R; Courtney SE; Weisner MD; Habib RH J Appl Physiol (1985); 2012 Apr; 112(7):1105-13. PubMed ID: 22207721 [TBL] [Abstract][Full Text] [Related]
6. New generation neonatal high frequency ventilators: effect of oscillatory frequency and working principles on performance. Grazioli S; Karam O; Rimensberger PC Respir Care; 2015 Mar; 60(3):363-70. PubMed ID: 25406342 [TBL] [Abstract][Full Text] [Related]
7. Reliable tidal volume estimates at the airway opening with an infant monitor during high-frequency oscillatory ventilation. Scalfaro P; Pillow JJ; Sly PD; Cotting J Crit Care Med; 2001 Oct; 29(10):1925-30. PubMed ID: 11588453 [TBL] [Abstract][Full Text] [Related]
8. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
9. Influence of endotracheal tube bore on tidal volume during high frequency oscillatory ventilation: a model lung study. Hirao O; Iguchi N; Uchiyama A; Mashimo T; Nishimura M; Fujino Y Med Sci Monit; 2009 Jan; 15(1):MT1-4. PubMed ID: 19114975 [TBL] [Abstract][Full Text] [Related]
11. Are All Oscillators Created Equal? In vitro Performance Characteristics of Eight High-Frequency Oscillatory Ventilators. Tingay DG; John J; Harcourt ER; Black D; Dargaville PA; Mills JF; Davis PG Neonatology; 2015; 108(3):220-8. PubMed ID: 26304262 [TBL] [Abstract][Full Text] [Related]
12. Dräger VN500's oscillatory performance has a frequency-dependent threshold. John J; Harcourt ER; Davis PG; Tingay DG J Paediatr Child Health; 2014 Jan; 50(1):27-31. PubMed ID: 24118670 [TBL] [Abstract][Full Text] [Related]
13. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment]. Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533 [TBL] [Abstract][Full Text] [Related]
14. Pressure loss caused by pediatric endotracheal tubes during high-frequency-oscillation-ventilation. Schumann S; Krappitz M; Möller K; Hentschel R; Braun G; Guttmann J Respir Physiol Neurobiol; 2008 Jul; 162(2):132-7. PubMed ID: 18571997 [TBL] [Abstract][Full Text] [Related]
15. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode. Tung A; Drum ML; Morgan S J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723 [TBL] [Abstract][Full Text] [Related]
16. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
18. Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume. Al-Majed SI; Thompson JE; Watson KF; Randolph AG Crit Care; 2004 Dec; 8(6):R398-402. PubMed ID: 15566583 [TBL] [Abstract][Full Text] [Related]
19. Reduction of oscillatory pressure along the endotracheal tube is indicative for maximal respiratory compliance during high-frequency oscillatory ventilation: a mathematical model study. van Genderingen HR; Versprille A; Leenhoven T; Markhorst DG; van Vught AJ; Heethaar RM Pediatr Pulmonol; 2001 Jun; 31(6):458-63. PubMed ID: 11389579 [TBL] [Abstract][Full Text] [Related]
20. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings. Hentschel R; Buntzel J; Guttmann J; Schumann S Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]