These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 11599067)

  • 1. Three-dimensional MR pulmonary perfusion imaging and angiography with an injection of a new blood pool contrast agent B-22956/1.
    Zheng J; Carr J; Harris K; Saker MB; Cavagna FM; Maggioni F; Laub G; Li D; Finn JP
    J Magn Reson Imaging; 2001 Oct; 14(4):425-32. PubMed ID: 11599067
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent.
    Fink C; Ley S; Puderbach M; Plathow C; Bock M; Kauczor HU
    Eur Radiol; 2004 Jul; 14(7):1291-6. PubMed ID: 14997336
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MR diagnosis of a pulmonary embolism: comparison of P792 and Gd-DOTA for first-pass perfusion MRI and contrast-enhanced 3D MRA in a rabbit model.
    Keilholz SD; Bozlar U; Fujiwara N; Mata JF; Berr SS; Corot C; Hagspiel KD
    Korean J Radiol; 2009; 10(5):447-54. PubMed ID: 19721829
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines.
    Bannas P; Bell LC; Johnson KM; Schiebler ML; François CJ; Motosugi U; Consigny D; Reeder SB; Nagle SK
    Radiology; 2016 Feb; 278(2):413-21. PubMed ID: 26422185
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic resonance imaging detection of an experimental pulmonary perfusion deficit using a macromolecular contrast agent. Polylysine-gadolinium-DTPA40.
    Berthezène Y; Vexler V; Price DC; Wisner-Dupon J; Moseley ME; Aicher KP; Brasch RC
    Invest Radiol; 1992 May; 27(5):346-51. PubMed ID: 1582816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulmonary perfusion and angiography: evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE.
    Hatabu H; Gaa J; Kim D; Li W; Prasad PV; Edelman RR
    AJR Am J Roentgenol; 1996 Sep; 167(3):653-5. PubMed ID: 8751673
    [No Abstract]   [Full Text] [Related]  

  • 7. Combined MR proton lung perfusion/angiography and helium ventilation: potential for detecting pulmonary emboli and ventilation defects.
    Zheng J; Leawoods JC; Nolte M; Yablonskiy DA; Woodard PK; Laub G; Gropler RJ; Conradi MS
    Magn Reson Med; 2002 Mar; 47(3):433-8. PubMed ID: 11870828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.
    Hong C; Leawoods JC; Yablonskiy DA; Leyendecker JR; Bae KT; Pilgram TK; Woodard PK; Conradi MS; Zheng J
    Acad Radiol; 2005 Feb; 12(2):202-9. PubMed ID: 15721597
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulmonary ventilation-perfusion MR imaging in clinical patients.
    Nakagawa T; Sakuma H; Murashima S; Ishida N; Matsumura K; Takeda K
    J Magn Reson Imaging; 2001 Oct; 14(4):419-24. PubMed ID: 11599066
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulmonary embolism: comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial spin tagging, and contrast-enhanced MRA.
    Altes TA; Mai VM; Munger TM; Brookeman JR; Hagspiel KD
    J Vasc Interv Radiol; 2005 Jul; 16(7):999-1005. PubMed ID: 16002508
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of first-pass Gd-DOTA and FAIRER MR perfusion imaging in a rabbit model of pulmonary embolism.
    Keilholz SD; Mai VM; Berr SS; Fujiwara N; Hagspiel KD
    J Magn Reson Imaging; 2002 Aug; 16(2):168-71. PubMed ID: 12203764
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulmonary MR perfusion at 3.0 Tesla using a blood pool contrast agent: Initial results in a swine model.
    Nael K; Saleh R; Nyborg GK; Fonseca CG; Weinmann HJ; Laub G; Finn JP
    J Magn Reson Imaging; 2007 Jan; 25(1):66-72. PubMed ID: 17154181
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Time-resolved three-dimensional pulmonary MR angiography and perfusion imaging with ultrashort repetition time.
    Carr JC; Laub G; Zheng J; Pereles FS; Finn JP
    Acad Radiol; 2002 Dec; 9(12):1407-18. PubMed ID: 12553352
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic contrast-enhanced MR angiography of pulmonary embolism: comparison with pulmonary angiography.
    Loubeyre P; Revel D; Douek P; Delignette A; Baldy C; Genin G; Amiel M
    AJR Am J Roentgenol; 1994 May; 162(5):1035-9. PubMed ID: 8165977
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic resonance imaging of myocardial perfusion and viability using a blood pool contrast agent.
    Dewey M; Kaufels N; Laule M; Schnorr J; Raynaud JS; Hamm B; Taupitz M
    Invest Radiol; 2004 Aug; 39(8):498-505. PubMed ID: 15257211
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulmonary embolism: detection with MR perfusion imaging of lung--a feasibility study.
    Amundsen T; Kvaerness J; Jones RA; Waage A; Bjermer L; Nilsen G; Haraldseth O
    Radiology; 1997 Apr; 203(1):181-5. PubMed ID: 9122390
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of models and contrast agents for improved signal and signal linearity in dynamic contrast-enhanced pulmonary magnetic resonance imaging.
    Bell LC; Wang K; Munoz Del Rio A; Grist TM; Fain SB; Nagle SK
    Invest Radiol; 2015 Mar; 50(3):174-8. PubMed ID: 25501016
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric interpolated contrast-enhanced MRA for the diagnosis of pulmonary embolism in an ex vivo system.
    Biederer J; Liess C; Charalambous N; Heller M
    J Magn Reson Imaging; 2004 Apr; 19(4):428-37. PubMed ID: 15065166
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels.
    Fink C; Puderbach M; Ley S; Plathow C; Bock M; Zuna I; Kauczor HU
    Invest Radiol; 2004 Mar; 39(3):143-8. PubMed ID: 15076006
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulmonary CE-MR angiography and perfusion imaging.
    Fernandez GC
    Eur Radiol; 2004 May; 14 Suppl 5():M32-3. PubMed ID: 15458002
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.