131 related articles for article (PubMed ID: 11600119)
21. [A comparison of a fluoroscopy-free mechanical targeting system and a free-hand technic for the placement of distal interlocking screws of tibial nails].
Krettek C; Könemann B; Farouk O; Kromm A; Schandelamier P; Tscherne H
Chirurg; 1997 Nov; 68(11):1194-201. PubMed ID: 9518215
[TBL] [Abstract][Full Text] [Related]
22. Intramedullary nailing of the femur with an inflatable self-locking nail: comparison with locked nailing.
Lepore L; Lepore S; Maffulli N
J Orthop Sci; 2003; 8(6):796-801. PubMed ID: 14648267
[TBL] [Abstract][Full Text] [Related]
23. Comparing Results between New Aiming Device and Freehand Technique for Distal Locking of Intramedullary Implants.
Wattanakitkrileart S; Tangtrakulwanich B; Yuenyongviwat V
J Med Assoc Thai; 2016 Nov; 99(11):1180-4. PubMed ID: 29901924
[TBL] [Abstract][Full Text] [Related]
24. Extending fixation beyond the working length of an intramedullary nail with a linked intramedullary and extramedullary fixation in complex femoral fractures; a brief series.
Venkateswaran B; Smith RM
Injury; 2001 Nov; 32(9):719-24. PubMed ID: 11600120
[TBL] [Abstract][Full Text] [Related]
25. Inserting the distal screws in a locked femoral nail.
Knudsen CJ; Grobler GP; Close RE
J Bone Joint Surg Br; 1991 Jul; 73(4):660-1. PubMed ID: 2071655
[TBL] [Abstract][Full Text] [Related]
26. [Insertion of distal screws in interlocking nailing using a new free-hand control device].
Pennig D; Brug E
Unfallchirurg; 1989 Jul; 92(7):331-4. PubMed ID: 2762819
[TBL] [Abstract][Full Text] [Related]
27. A prospective evaluation of the AO/ASIF universal femoral nail in the treatment of traumatic and reconstructive problems of the femur.
Seiler JG; Swiontkowski MF
J Trauma; 1991 Jan; 31(1):121-6. PubMed ID: 1986117
[TBL] [Abstract][Full Text] [Related]
28. [Electromagnetic navigation interlocking intramedullary nail technology for treatment of femoral shaft fractures].
Zuo K; Qin W; Guo Q; Palati-Ababaikeli ; Qiao P; Shen M; Yin L; Pan Q; Xu X
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Oct; 28(10):1204-7. PubMed ID: 25591292
[TBL] [Abstract][Full Text] [Related]
29. Experimental model for a new distal locking aiming device for solid intramedullary tibia nails.
Abdlslam KM; Bonnaire F
Injury; 2003 May; 34(5):363-6. PubMed ID: 12719165
[TBL] [Abstract][Full Text] [Related]
30. [Borderline indications for locked intramedullary nailing of femur and tibia].
Vécsei V; Seitz H; Greitbauer M; Heinz T
Orthopade; 1996 Jun; 25(3):234-46. PubMed ID: 8766662
[TBL] [Abstract][Full Text] [Related]
31. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
[TBL] [Abstract][Full Text] [Related]
32. Infra-isthmal fracture is a risk factor for nonunion after femoral nailing: a case-control study.
Watanabe Y; Takenaka N; Kobayashi M; Matsushita T
J Orthop Sci; 2013 Jan; 18(1):76-80. PubMed ID: 23053587
[TBL] [Abstract][Full Text] [Related]
33. Penetration of the distal femur by the distal locking device of Brooker Wills interlocking nail.
Ebraheim NA; Paley KJ
Clin Orthop Relat Res; 1993 Dec; (297):218-23. PubMed ID: 8242934
[TBL] [Abstract][Full Text] [Related]
34. Increasing nail-cortical contact to increase fixation stability and decrease implant strain in antegrade locked nailing of distal femoral fractures: a biomechanical study.
Huang SC; Lin CC; Lin J
J Trauma; 2009 Feb; 66(2):436-42. PubMed ID: 19065112
[TBL] [Abstract][Full Text] [Related]
35. Results of the long Gamma nail for complex proximal femoral fractures.
Pervez H; Parker MJ
Injury; 2001 Nov; 32(9):704-7. PubMed ID: 11600117
[TBL] [Abstract][Full Text] [Related]
36. Targeting device for intramedullary nails: a new high-stable mechanical guide.
Arlettaz Y; Akiki A; Chevalley F; Leyvraz PF
Injury; 2008 Feb; 39(2):170-5. PubMed ID: 17884055
[TBL] [Abstract][Full Text] [Related]
37. A new distal targeting device for closed interlocking nailing.
Tyropoulos S; Garnavos C
Injury; 2001 Nov; 32(9):732-5. PubMed ID: 11600124
[TBL] [Abstract][Full Text] [Related]
38. Unreamed intramedullary nailing for pathological femoral fractures. Good results in 30 cases.
Giannoudis PV; Bastawrous SS; Bunola JA; Macdonald DA; Smith RM
Acta Orthop Scand; 1999 Feb; 70(1):29-32. PubMed ID: 10191744
[TBL] [Abstract][Full Text] [Related]
39. Imaging Evaluation of the Safe Region for Distal Locking Screw of Proximal Femoral Nail Anti-Rotation in Patients with Proximal Femoral Fracture.
Gong J; Liu P; Cai M
Med Sci Monit; 2017 Feb; 23():719-724. PubMed ID: 28178228
[TBL] [Abstract][Full Text] [Related]
40. The clinical performance of a small diameter tibial nailing system with a mechanical distal aiming device.
Karachalios T; Babis G; Tsarouchas J; Sapkas G; Pantazopoulos T
Injury; 2000 Jul; 31(6):451-9. PubMed ID: 10831746
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]