These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 11604334)

  • 1. An alternative system for cerebrovascular reconstructions: non-penetrating arcuate-legged clips.
    Kirsch WM; Cavallo C; Anton T; Zhu YH; Rouse G; Martin R; Fukushima T; Rose J
    Cardiovasc Surg; 2001 Dec; 9(6):531-9. PubMed ID: 11604334
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of nonpenetrating clips on intimal hyperplasia of vascular anastomoses.
    Berman SS; Kirsch WM; Zhu YH; Anton L; Chai Y
    Cardiovasc Surg; 2001 Dec; 9(6):540-7. PubMed ID: 11604335
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sutureless vascular anastomosis: the VCS clip.
    Kirsch WM; Gupta S; Zhu YH
    Cardiovasc Surg; 2001 Dec; 9(6):523-5. PubMed ID: 11604332
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evolution of staples and clips for vascular anastomoses.
    Zeebregts CJ; Kirsch WM; van den Dungen JJ; van Schilfgaarde R; Zhu YH
    Int Surg; 2004; 89(3):152-60. PubMed ID: 15521252
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tissue reconstruction with nonpenetrating arcuate-legged clips. Potential endoscopic applications.
    Kirsch WM; Zhu YH; Gaskill D; Stewart S; Hardesty RA; Lyons TL
    J Reprod Med; 1992 Jul; 37(7):581-6. PubMed ID: 1522566
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Five years' world experience with nonpenetrating clips for vascular anastomoses.
    Zeebregts CJ; Kirsch WM; van den Dungen JJ; Zhu YH; van Schilfgaarde R
    Am J Surg; 2004 Jun; 187(6):751-60. PubMed ID: 15191871
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical experience with non-penetrating vascular clips in free-flap reconstructions.
    Zeebregts C; Acosta R; Bölander L; van Schilfgaarde R; Jakobsson O
    Br J Plast Surg; 2002 Mar; 55(2):105-10. PubMed ID: 11987941
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Vein patch angioplasty with non-penetrating titanium clips. Comparison to standard suture technique.
    Pikoulis E; Rhee P; Nishibe T; Koronarchis D; Leppäniemi A; Karavokyros I; Burris D; Bakoyiannis C; Fishback N; Wherry D; Rich N
    Acta Chir Belg; 2009; 109(6):756-9. PubMed ID: 20184062
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Vascular closure system type of nonpenetrating arcuate-legged titanium clips for graft-artery and graft-graft anastomoses: review of our clinical experience.
    Inoue Y; Kubota T; Jibiki M; Hirokawa M; Sugano N; Iwai T
    Surg Today; 2004; 34(3):231-6. PubMed ID: 14999535
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Direct repair of a blisterlike aneurysm on the internal carotid artery with vascular closure staple clips. Technical note.
    Yanagisawa T; Mizoi K; Sugawara T; Suzuki A; Ohta T; Higashiyama N; Takahashi M; Sasajima T; Kinouchi H
    J Neurosurg; 2004 Jan; 100(1):146-9. PubMed ID: 14743928
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Venous anastomosis using a non-penetrating vascular closure system in orthotopic liver transplantation.
    Wang Y; Xin Z; Pan B; Lv SC; Zhang XM; Zhang ZH; Li LX; Li XL; He Q
    Clin Transplant; 2017 Dec; 31(12):. PubMed ID: 28944583
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid arterial anastomosis with titanium clips.
    Pikoulis E; Burris D; Rhee P; Nishibe T; Leppäniemi A; Wherry D; Rich N
    Am J Surg; 1998 Jun; 175(6):494-6. PubMed ID: 9645780
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The VCS clip--experimental experiences with a new vascular suture stapling device].
    Golling M; Mehrabi A; Weiss G; Schäffer F; Kraus T; Klar E
    Chirurg; 1999 Feb; 70(2):206-10. PubMed ID: 10097867
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of a novel penetrating, sutureless anastomotic device in arterial microvascular anastomoses.
    Baynosa RC; Stutman R; Mahabir RC; Zamboni WA; Khiabani KT
    J Reconstr Microsurg; 2008 Jan; 24(1):39-42. PubMed ID: 18548377
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Arcuate-legged nonpenetrating vascular closure staples (VCS): early experience.
    Sultan SA; Madhavan P; Evoy D; Purcell EM; Colgan MP; Moore DJ; Shanik GD
    Ann Vasc Surg; 2001 May; 15(3):338-42. PubMed ID: 11414085
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of a new fenestrated clip (Yaşargil T-bar clip) for the treatment of fusiform M1 aneurysm: case illustration and technical report.
    Başkaya MK; Uluç K
    Neurosurgery; 2012 Jun; 70(2 Suppl Operative):339-42. PubMed ID: 21869719
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Self-closing surgical clips for use in pericallosal artery-pericallosal artery side-to-side bypass.
    Ferroli P; Ciceri E; Addis A; Broggi G
    J Neurosurg; 2008 Aug; 109(2):330-4. PubMed ID: 18671649
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clip blade scissoring with titanium bayonet clip in aneurysm surgery. Two case reports.
    Horiuchi T; Li Y; Seguchi T; Sato A; Aoyama T; Hanaoka Y; Hongo K
    Neurol Med Chir (Tokyo); 2012; 52(2):84-6. PubMed ID: 22362289
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Straight Fenestrated Clips in Surgical Management of Internal Carotid Artery Aneurysms: Technical Note.
    Oshida S; Kashimura H; Suzuki T; Aso K; Akamatsu Y
    World Neurosurg; 2018 Aug; 116():230-233. PubMed ID: 29852308
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoropopliteal and distal bypasses with arterial anastomsis performed by titanium clips.
    Balar NN; Gupta SK; Sampson LN; Deshmukh N; Ayerdi J
    Cardiovasc Surg; 2001 Dec; 9(6):548-51. PubMed ID: 11604336
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.