These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
110 related articles for article (PubMed ID: 11669052)
1. [Digital X-ray apparatus "Sibir'". Measurement of the value of a signal]. Babichev EA; Baru SE; Neustroev VA; Porosev VV; Savinov GA; Sidorov VA; Ukraintsev IuG; Khabakpachev AG; Shekhtman LI; Iurchenko IuR Med Tekh; 2001; (5):3-7. PubMed ID: 11669052 [TBL] [Abstract][Full Text] [Related]
2. [Definition of quantum efficiency of X-ray detectors]. Zelikman MI Med Tekh; 2001; (4):5-11. PubMed ID: 11534295 [TBL] [Abstract][Full Text] [Related]
3. [Methods of automatic control of the characteristics of digital X-ray detectors]. Berdiakov GI; Zelikman MI; Rtishcheva GM Med Tekh; 2001; (5):12-5. PubMed ID: 11669046 [TBL] [Abstract][Full Text] [Related]
4. The evolution of digital radiography: from storage phosphors to flat-panel detectors. Porcelli A; Maggi F; Spalvieri S; Meduri A; Marano P Rays; 2003; 28(1):5-12. PubMed ID: 14509175 [TBL] [Abstract][Full Text] [Related]
5. Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1. Illers H; Buhr E; Hoeschen C Radiat Prot Dosimetry; 2005; 114(1-3):39-44. PubMed ID: 15933079 [TBL] [Abstract][Full Text] [Related]
6. [Analysis of factors affecting the results of estimation of the detective quantum efficiency of digital X-ray detectors within high and low spatial frequency ranges]. Zelikman MI; Kabanov SP; Kruchinin SA; Lobov DP Med Tekh; 2007; (5):6-9. PubMed ID: 18030766 [TBL] [Abstract][Full Text] [Related]
7. [Generalized quantum efficacy of digital x-ray devices]. Mazurov AI Med Tekh; 2008; (5):1-4. PubMed ID: 19048859 [No Abstract] [Full Text] [Related]
8. Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics. Cowen AR; Kengyelics SM; Davies AG Clin Radiol; 2008 May; 63(5):487-98. PubMed ID: 18374710 [TBL] [Abstract][Full Text] [Related]
9. An examination of automatic exposure control regimes for two digital radiography systems. Marshall NW Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115 [TBL] [Abstract][Full Text] [Related]
10. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography. Cowen AR; Davies AG; Sivananthan MU Clin Radiol; 2008 Oct; 63(10):1073-85. PubMed ID: 18774353 [TBL] [Abstract][Full Text] [Related]
11. Digital hardware in radiography and fluoroscopy. Gould RG Appl Radiol; 1984; 13(3):137-40. PubMed ID: 10299566 [TBL] [Abstract][Full Text] [Related]
12. Status and prospects of digital detector technology for CR and DR. Neitzel U Radiat Prot Dosimetry; 2005; 114(1-3):32-8. PubMed ID: 15933078 [TBL] [Abstract][Full Text] [Related]
13. [Methods of assessing the parameter detail-contrast of X-ray converting receivers]. Blinov NN; Gorelik FG; Zelikman MI Med Tekh; 2001; (5):17-9. PubMed ID: 11669048 [TBL] [Abstract][Full Text] [Related]
14. [Analysis of the advantages of digital X-ray apparatuses over film X-ray apparatuses]. Elinson MB Med Tekh; 2005; (5):37-9. PubMed ID: 16285246 [TBL] [Abstract][Full Text] [Related]
15. Calibrating automatic exposure control devices for digital radiography. Doyle P; Martin CJ Phys Med Biol; 2006 Nov; 51(21):5475-85. PubMed ID: 17047264 [TBL] [Abstract][Full Text] [Related]
16. A comparison between objective and subjective image quality measurements for a full field digital mammography system. Marshall NW Phys Med Biol; 2006 May; 51(10):2441-63. PubMed ID: 16675862 [TBL] [Abstract][Full Text] [Related]
17. Digital radiography. Kruger RA Mead Johnson Symp Perinat Dev Med; 1987; (25):4-9. PubMed ID: 3506961 [No Abstract] [Full Text] [Related]
18. Digital radiography: image quality and radiation dose. Seibert JA Health Phys; 2008 Nov; 95(5):586-98. PubMed ID: 18849693 [TBL] [Abstract][Full Text] [Related]